Cargando…
High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring
This paper presented a new sensor to detect and localize partial discharge (PD) in power transformers based on a fiber Bragg grating (FBG). The fundamental characteristics of the proposed sensor, as a PD detector, were temperature compensation and direction independence. The proposed high-resolution...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929056/ https://www.ncbi.nlm.nih.gov/pubmed/31801278 http://dx.doi.org/10.3390/s19235285 |
_version_ | 1783482616154947584 |
---|---|
author | Ghorat, Mohsen Gharehpetian, Gevork B. Latifi, Hamid Hejazi, Maryam A. Bagheri, Mehdi |
author_facet | Ghorat, Mohsen Gharehpetian, Gevork B. Latifi, Hamid Hejazi, Maryam A. Bagheri, Mehdi |
author_sort | Ghorat, Mohsen |
collection | PubMed |
description | This paper presented a new sensor to detect and localize partial discharge (PD) in power transformers based on a fiber Bragg grating (FBG). The fundamental characteristics of the proposed sensor, as a PD detector, were temperature compensation and direction independence. The proposed high-resolution PD detector operated based on the FBG wavelength shift. It is necessary to evaluate the physical parameters of the sensor to achieve the best results. Therefore, in this paper, the detected signal strength was investigated for different angles and temperatures. A Teflon hollow mandrel and two FBGs attached to the inner and outer surfaces of the hollow mandrel were chosen as the inner transformer PD detector. The changes in the sensor output were less than 0.4 mV and 0.5 mV for direction variations and a temperature variation of 14 °C (degrees Celsius), respectively. Consequently, the proposed sensor could be successfully employed for the detection of a transformer PD signal. |
format | Online Article Text |
id | pubmed-6929056 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69290562019-12-26 High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring Ghorat, Mohsen Gharehpetian, Gevork B. Latifi, Hamid Hejazi, Maryam A. Bagheri, Mehdi Sensors (Basel) Article This paper presented a new sensor to detect and localize partial discharge (PD) in power transformers based on a fiber Bragg grating (FBG). The fundamental characteristics of the proposed sensor, as a PD detector, were temperature compensation and direction independence. The proposed high-resolution PD detector operated based on the FBG wavelength shift. It is necessary to evaluate the physical parameters of the sensor to achieve the best results. Therefore, in this paper, the detected signal strength was investigated for different angles and temperatures. A Teflon hollow mandrel and two FBGs attached to the inner and outer surfaces of the hollow mandrel were chosen as the inner transformer PD detector. The changes in the sensor output were less than 0.4 mV and 0.5 mV for direction variations and a temperature variation of 14 °C (degrees Celsius), respectively. Consequently, the proposed sensor could be successfully employed for the detection of a transformer PD signal. MDPI 2019-11-30 /pmc/articles/PMC6929056/ /pubmed/31801278 http://dx.doi.org/10.3390/s19235285 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ghorat, Mohsen Gharehpetian, Gevork B. Latifi, Hamid Hejazi, Maryam A. Bagheri, Mehdi High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title | High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title_full | High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title_fullStr | High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title_full_unstemmed | High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title_short | High-Resolution FBG-Based Fiber-Optic Sensor with Temperature Compensation for PD Monitoring |
title_sort | high-resolution fbg-based fiber-optic sensor with temperature compensation for pd monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929056/ https://www.ncbi.nlm.nih.gov/pubmed/31801278 http://dx.doi.org/10.3390/s19235285 |
work_keys_str_mv | AT ghoratmohsen highresolutionfbgbasedfiberopticsensorwithtemperaturecompensationforpdmonitoring AT gharehpetiangevorkb highresolutionfbgbasedfiberopticsensorwithtemperaturecompensationforpdmonitoring AT latifihamid highresolutionfbgbasedfiberopticsensorwithtemperaturecompensationforpdmonitoring AT hejazimaryama highresolutionfbgbasedfiberopticsensorwithtemperaturecompensationforpdmonitoring AT bagherimehdi highresolutionfbgbasedfiberopticsensorwithtemperaturecompensationforpdmonitoring |