Cargando…

Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration

Phase difference measurement of sinusoidal signals can be used for phase error calibration of the spaceborne single-pass interferometric synthetic aperture radar (InSAR) system. However, there are currently very few papers devoted to the discussion of phase difference measurement of high-frequency i...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Zhihui, Gu, Yice, Xing, Xuemin, Chen, Lifu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929184/
https://www.ncbi.nlm.nih.gov/pubmed/31816992
http://dx.doi.org/10.3390/s19235328
_version_ 1783482646491299840
author Yuan, Zhihui
Gu, Yice
Xing, Xuemin
Chen, Lifu
author_facet Yuan, Zhihui
Gu, Yice
Xing, Xuemin
Chen, Lifu
author_sort Yuan, Zhihui
collection PubMed
description Phase difference measurement of sinusoidal signals can be used for phase error calibration of the spaceborne single-pass interferometric synthetic aperture radar (InSAR) system. However, there are currently very few papers devoted to the discussion of phase difference measurement of high-frequency internal calibration signals of the InSAR system, especially the discussion of sampling frequency selection and the corresponding measuring method when the high-frequency signals are sampled under the under-sampling condition. To solve this problem, a phase difference measurement method for high-frequency sinusoidal signals is proposed, and the corresponding sampling frequency selection criteria under the under-sampling condition is determined. First, according to the selection criteria, the appropriate under-sampling frequency was chosen to sample the two sinusoidal signals with the same frequency. Then, the sampled signals were filtered by limited recursive average filtering (LRAF) and coherently accumulated in the cycle of the baseband signal. Third, the filtered and accumulated signals were used to calculate the phase difference of the two sinusoidal signals using the discrete Fourier transform (DFT), digital correlation (DC), and Hilbert transform (HT)-based methods. Lastly, the measurement accuracy of the three methods were compared respectively by different simulation experiments. Theoretical analysis and experiments verified the effectiveness of the proposed method for the phase error calibration of the InSAR system.
format Online
Article
Text
id pubmed-6929184
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69291842019-12-26 Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration Yuan, Zhihui Gu, Yice Xing, Xuemin Chen, Lifu Sensors (Basel) Article Phase difference measurement of sinusoidal signals can be used for phase error calibration of the spaceborne single-pass interferometric synthetic aperture radar (InSAR) system. However, there are currently very few papers devoted to the discussion of phase difference measurement of high-frequency internal calibration signals of the InSAR system, especially the discussion of sampling frequency selection and the corresponding measuring method when the high-frequency signals are sampled under the under-sampling condition. To solve this problem, a phase difference measurement method for high-frequency sinusoidal signals is proposed, and the corresponding sampling frequency selection criteria under the under-sampling condition is determined. First, according to the selection criteria, the appropriate under-sampling frequency was chosen to sample the two sinusoidal signals with the same frequency. Then, the sampled signals were filtered by limited recursive average filtering (LRAF) and coherently accumulated in the cycle of the baseband signal. Third, the filtered and accumulated signals were used to calculate the phase difference of the two sinusoidal signals using the discrete Fourier transform (DFT), digital correlation (DC), and Hilbert transform (HT)-based methods. Lastly, the measurement accuracy of the three methods were compared respectively by different simulation experiments. Theoretical analysis and experiments verified the effectiveness of the proposed method for the phase error calibration of the InSAR system. MDPI 2019-12-03 /pmc/articles/PMC6929184/ /pubmed/31816992 http://dx.doi.org/10.3390/s19235328 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yuan, Zhihui
Gu, Yice
Xing, Xuemin
Chen, Lifu
Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title_full Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title_fullStr Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title_full_unstemmed Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title_short Phase Difference Measurement of Under-Sampled Sinusoidal Signals for InSAR System Phase Error Calibration
title_sort phase difference measurement of under-sampled sinusoidal signals for insar system phase error calibration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929184/
https://www.ncbi.nlm.nih.gov/pubmed/31816992
http://dx.doi.org/10.3390/s19235328
work_keys_str_mv AT yuanzhihui phasedifferencemeasurementofundersampledsinusoidalsignalsforinsarsystemphaseerrorcalibration
AT guyice phasedifferencemeasurementofundersampledsinusoidalsignalsforinsarsystemphaseerrorcalibration
AT xingxuemin phasedifferencemeasurementofundersampledsinusoidalsignalsforinsarsystemphaseerrorcalibration
AT chenlifu phasedifferencemeasurementofundersampledsinusoidalsignalsforinsarsystemphaseerrorcalibration