Cargando…

Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques

BACKGROUND: Group B streptococcus (GBS) is an important pathogen that is responsible for invasive infections, including sepsis and meningitis. GBS serotyping is an essential means for the investigation of possible infection outbreaks and can identify possible sources of infection. Although it is pos...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hsin-Yao, Li, Wen-Chi, Huang, Kai-Yao, Chung, Chia-Ru, Horng, Jorng-Tzong, Hsu, Jen-Fu, Lu, Jang-Jih, Lee, Tzong-Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929280/
https://www.ncbi.nlm.nih.gov/pubmed/31870283
http://dx.doi.org/10.1186/s12859-019-3282-7
_version_ 1783482668101402624
author Wang, Hsin-Yao
Li, Wen-Chi
Huang, Kai-Yao
Chung, Chia-Ru
Horng, Jorng-Tzong
Hsu, Jen-Fu
Lu, Jang-Jih
Lee, Tzong-Yi
author_facet Wang, Hsin-Yao
Li, Wen-Chi
Huang, Kai-Yao
Chung, Chia-Ru
Horng, Jorng-Tzong
Hsu, Jen-Fu
Lu, Jang-Jih
Lee, Tzong-Yi
author_sort Wang, Hsin-Yao
collection PubMed
description BACKGROUND: Group B streptococcus (GBS) is an important pathogen that is responsible for invasive infections, including sepsis and meningitis. GBS serotyping is an essential means for the investigation of possible infection outbreaks and can identify possible sources of infection. Although it is possible to determine GBS serotypes by either immuno-serotyping or geno-serotyping, both traditional methods are time-consuming and labor-intensive. In recent years, the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been reported as an effective tool for the determination of GBS serotypes in a more rapid and accurate manner. Thus, this work aims to investigate GBS serotypes by incorporating machine learning techniques with MALDI-TOF MS to carry out the identification. RESULTS: In this study, a total of 787 GBS isolates, obtained from three research and teaching hospitals, were analyzed by MALDI-TOF MS, and the serotype of the GBS was determined by a geno-serotyping experiment. The peaks of mass-to-charge ratios were regarded as the attributes to characterize the various serotypes of GBS. Machine learning algorithms, such as support vector machine (SVM) and random forest (RF), were then used to construct predictive models for the five different serotypes (Types Ia, Ib, III, V, and VI). After optimization of feature selection and model generation based on training datasets, the accuracies of the selected models attained 54.9–87.1% for various serotypes based on independent testing data. Specifically, for the major serotypes, namely type III and type VI, the accuracies were 73.9 and 70.4%, respectively. CONCLUSION: The proposed models have been adopted to implement a web-based tool (GBSTyper), which is now freely accessible at http://csb.cse.yzu.edu.tw/GBSTyper/, for providing efficient and effective detection of GBS serotypes based on a MALDI-TOF MS spectrum. Overall, this work has demonstrated that the combination of MALDI-TOF MS and machine intelligence could provide a practical means of clinical pathogen testing.
format Online
Article
Text
id pubmed-6929280
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69292802019-12-30 Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques Wang, Hsin-Yao Li, Wen-Chi Huang, Kai-Yao Chung, Chia-Ru Horng, Jorng-Tzong Hsu, Jen-Fu Lu, Jang-Jih Lee, Tzong-Yi BMC Bioinformatics Research BACKGROUND: Group B streptococcus (GBS) is an important pathogen that is responsible for invasive infections, including sepsis and meningitis. GBS serotyping is an essential means for the investigation of possible infection outbreaks and can identify possible sources of infection. Although it is possible to determine GBS serotypes by either immuno-serotyping or geno-serotyping, both traditional methods are time-consuming and labor-intensive. In recent years, the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been reported as an effective tool for the determination of GBS serotypes in a more rapid and accurate manner. Thus, this work aims to investigate GBS serotypes by incorporating machine learning techniques with MALDI-TOF MS to carry out the identification. RESULTS: In this study, a total of 787 GBS isolates, obtained from three research and teaching hospitals, were analyzed by MALDI-TOF MS, and the serotype of the GBS was determined by a geno-serotyping experiment. The peaks of mass-to-charge ratios were regarded as the attributes to characterize the various serotypes of GBS. Machine learning algorithms, such as support vector machine (SVM) and random forest (RF), were then used to construct predictive models for the five different serotypes (Types Ia, Ib, III, V, and VI). After optimization of feature selection and model generation based on training datasets, the accuracies of the selected models attained 54.9–87.1% for various serotypes based on independent testing data. Specifically, for the major serotypes, namely type III and type VI, the accuracies were 73.9 and 70.4%, respectively. CONCLUSION: The proposed models have been adopted to implement a web-based tool (GBSTyper), which is now freely accessible at http://csb.cse.yzu.edu.tw/GBSTyper/, for providing efficient and effective detection of GBS serotypes based on a MALDI-TOF MS spectrum. Overall, this work has demonstrated that the combination of MALDI-TOF MS and machine intelligence could provide a practical means of clinical pathogen testing. BioMed Central 2019-12-24 /pmc/articles/PMC6929280/ /pubmed/31870283 http://dx.doi.org/10.1186/s12859-019-3282-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wang, Hsin-Yao
Li, Wen-Chi
Huang, Kai-Yao
Chung, Chia-Ru
Horng, Jorng-Tzong
Hsu, Jen-Fu
Lu, Jang-Jih
Lee, Tzong-Yi
Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title_full Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title_fullStr Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title_full_unstemmed Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title_short Rapid classification of group B Streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
title_sort rapid classification of group b streptococcus serotypes based on matrix-assisted laser desorption ionization-time of flight mass spectrometry and machine learning techniques
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929280/
https://www.ncbi.nlm.nih.gov/pubmed/31870283
http://dx.doi.org/10.1186/s12859-019-3282-7
work_keys_str_mv AT wanghsinyao rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT liwenchi rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT huangkaiyao rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT chungchiaru rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT horngjorngtzong rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT hsujenfu rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT lujangjih rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques
AT leetzongyi rapidclassificationofgroupbstreptococcusserotypesbasedonmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryandmachinelearningtechniques