Cargando…

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

PURPOSE: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS: The study was conducted with internal type implants of two...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Yuseung, Heo, Seong-Joo, Koak, Jai-Young, Kim, Seong-Kyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933047/
https://www.ncbi.nlm.nih.gov/pubmed/31897269
http://dx.doi.org/10.4047/jap.2019.11.6.305
_version_ 1783483134289903616
author Yi, Yuseung
Heo, Seong-Joo
Koak, Jai-Young
Kim, Seong-Kyun
author_facet Yi, Yuseung
Heo, Seong-Joo
Koak, Jai-Young
Kim, Seong-Kyun
author_sort Yi, Yuseung
collection PubMed
description PURPOSE: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS: The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (10(6) cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS: There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION: The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.
format Online
Article
Text
id pubmed-6933047
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-69330472020-01-02 Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force Yi, Yuseung Heo, Seong-Joo Koak, Jai-Young Kim, Seong-Kyun J Adv Prosthodont Original Article PURPOSE: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS: The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (10(6) cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS: There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION: The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment. The Korean Academy of Prosthodontics 2019-12 2019-12-18 /pmc/articles/PMC6933047/ /pubmed/31897269 http://dx.doi.org/10.4047/jap.2019.11.6.305 Text en © 2019 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yi, Yuseung
Heo, Seong-Joo
Koak, Jai-Young
Kim, Seong-Kyun
Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title_full Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title_fullStr Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title_full_unstemmed Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title_short Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
title_sort comparison of cad/cam abutment and prefabricated abutment in morse taper internal type implant after cyclic loading: axial displacement, removal torque, and tensile removal force
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933047/
https://www.ncbi.nlm.nih.gov/pubmed/31897269
http://dx.doi.org/10.4047/jap.2019.11.6.305
work_keys_str_mv AT yiyuseung comparisonofcadcamabutmentandprefabricatedabutmentinmorsetaperinternaltypeimplantaftercyclicloadingaxialdisplacementremovaltorqueandtensileremovalforce
AT heoseongjoo comparisonofcadcamabutmentandprefabricatedabutmentinmorsetaperinternaltypeimplantaftercyclicloadingaxialdisplacementremovaltorqueandtensileremovalforce
AT koakjaiyoung comparisonofcadcamabutmentandprefabricatedabutmentinmorsetaperinternaltypeimplantaftercyclicloadingaxialdisplacementremovaltorqueandtensileremovalforce
AT kimseongkyun comparisonofcadcamabutmentandprefabricatedabutmentinmorsetaperinternaltypeimplantaftercyclicloadingaxialdisplacementremovaltorqueandtensileremovalforce