Effects of cementless fixation of implant prosthesis: A finite element study
PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933050/ https://www.ncbi.nlm.nih.gov/pubmed/31897273 http://dx.doi.org/10.4047/jap.2019.11.6.341 |
_version_ | 1783483134990352384 |
---|---|
author | Lee, Hyeonjong Park, Soyeon Kwon, Kung-Rock Noh, Gunwoo |
author_facet | Lee, Hyeonjong Park, Soyeon Kwon, Kung-Rock Noh, Gunwoo |
author_sort | Lee, Hyeonjong |
collection | PubMed |
description | PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS: The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS: Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 µm at the abutmentresin interface and 24.4 to 24.7 µm at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION: CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis. |
format | Online Article Text |
id | pubmed-6933050 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-69330502020-01-02 Effects of cementless fixation of implant prosthesis: A finite element study Lee, Hyeonjong Park, Soyeon Kwon, Kung-Rock Noh, Gunwoo J Adv Prosthodont Original Article PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS: The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS: Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 µm at the abutmentresin interface and 24.4 to 24.7 µm at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION: CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis. The Korean Academy of Prosthodontics 2019-12 2019-12-18 /pmc/articles/PMC6933050/ /pubmed/31897273 http://dx.doi.org/10.4047/jap.2019.11.6.341 Text en © 2019 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Hyeonjong Park, Soyeon Kwon, Kung-Rock Noh, Gunwoo Effects of cementless fixation of implant prosthesis: A finite element study |
title | Effects of cementless fixation of implant prosthesis: A finite element study |
title_full | Effects of cementless fixation of implant prosthesis: A finite element study |
title_fullStr | Effects of cementless fixation of implant prosthesis: A finite element study |
title_full_unstemmed | Effects of cementless fixation of implant prosthesis: A finite element study |
title_short | Effects of cementless fixation of implant prosthesis: A finite element study |
title_sort | effects of cementless fixation of implant prosthesis: a finite element study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933050/ https://www.ncbi.nlm.nih.gov/pubmed/31897273 http://dx.doi.org/10.4047/jap.2019.11.6.341 |
work_keys_str_mv | AT leehyeonjong effectsofcementlessfixationofimplantprosthesisafiniteelementstudy AT parksoyeon effectsofcementlessfixationofimplantprosthesisafiniteelementstudy AT kwonkungrock effectsofcementlessfixationofimplantprosthesisafiniteelementstudy AT nohgunwoo effectsofcementlessfixationofimplantprosthesisafiniteelementstudy |