Cargando…

Effects of cementless fixation of implant prosthesis: A finite element study

PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hyeonjong, Park, Soyeon, Kwon, Kung-Rock, Noh, Gunwoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933050/
https://www.ncbi.nlm.nih.gov/pubmed/31897273
http://dx.doi.org/10.4047/jap.2019.11.6.341
_version_ 1783483134990352384
author Lee, Hyeonjong
Park, Soyeon
Kwon, Kung-Rock
Noh, Gunwoo
author_facet Lee, Hyeonjong
Park, Soyeon
Kwon, Kung-Rock
Noh, Gunwoo
author_sort Lee, Hyeonjong
collection PubMed
description PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS: The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS: Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 µm at the abutmentresin interface and 24.4 to 24.7 µm at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION: CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.
format Online
Article
Text
id pubmed-6933050
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-69330502020-01-02 Effects of cementless fixation of implant prosthesis: A finite element study Lee, Hyeonjong Park, Soyeon Kwon, Kung-Rock Noh, Gunwoo J Adv Prosthodont Original Article PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS: The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS: Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 µm at the abutmentresin interface and 24.4 to 24.7 µm at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION: CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis. The Korean Academy of Prosthodontics 2019-12 2019-12-18 /pmc/articles/PMC6933050/ /pubmed/31897273 http://dx.doi.org/10.4047/jap.2019.11.6.341 Text en © 2019 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Hyeonjong
Park, Soyeon
Kwon, Kung-Rock
Noh, Gunwoo
Effects of cementless fixation of implant prosthesis: A finite element study
title Effects of cementless fixation of implant prosthesis: A finite element study
title_full Effects of cementless fixation of implant prosthesis: A finite element study
title_fullStr Effects of cementless fixation of implant prosthesis: A finite element study
title_full_unstemmed Effects of cementless fixation of implant prosthesis: A finite element study
title_short Effects of cementless fixation of implant prosthesis: A finite element study
title_sort effects of cementless fixation of implant prosthesis: a finite element study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933050/
https://www.ncbi.nlm.nih.gov/pubmed/31897273
http://dx.doi.org/10.4047/jap.2019.11.6.341
work_keys_str_mv AT leehyeonjong effectsofcementlessfixationofimplantprosthesisafiniteelementstudy
AT parksoyeon effectsofcementlessfixationofimplantprosthesisafiniteelementstudy
AT kwonkungrock effectsofcementlessfixationofimplantprosthesisafiniteelementstudy
AT nohgunwoo effectsofcementlessfixationofimplantprosthesisafiniteelementstudy