Cargando…

Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation

BACKGROUND: To investigate the efficacy and safety of continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30-gauge (G) needle. METHODS: Fifteen patients (15 eyes) with traumatic cyclodialysis cleft admitted to the ocular trauma department of our hospital...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Haibo, Cai, Jinhong, Li, Xiaofeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933675/
https://www.ncbi.nlm.nih.gov/pubmed/31878971
http://dx.doi.org/10.1186/s12886-019-1274-z
_version_ 1783483255639506944
author Li, Haibo
Cai, Jinhong
Li, Xiaofeng
author_facet Li, Haibo
Cai, Jinhong
Li, Xiaofeng
author_sort Li, Haibo
collection PubMed
description BACKGROUND: To investigate the efficacy and safety of continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30-gauge (G) needle. METHODS: Fifteen patients (15 eyes) with traumatic cyclodialysis cleft admitted to the ocular trauma department of our hospital from July 2014 to December 2018 were included in this study. After the bulbar conjunctiva corresponding to the ciliary body was incised along the corneal limbus, an incision was made along the corneal limbus on the opposite side. A 30G needle with a 10–0 suture entered the anterior chamber from the incision and passed through the ciliary body with clefts and the sclera to fixate the ciliary body on the sclera wall with continuous mattress suture. The best corrected visual acuity (BCVA) and intraocular pressure (IOP) were observed preoperatively and postoperatively. In vivo ultrasound biomicroscopy (UBM) was performed to observe closure of cyclodialysis cleft before and after surgery. RESULTS: Fifteen patients successfully underwent continuous mattress suture for repair of cyclodialysis cleft. No bleeding and suture breakage were reported during surgery. After surgery, the UBM during follow-up showed satisfactory closure of the cyclodialysis cleft. The BCVA and IOP were improved to different degrees. The difference between the preoperative IOP and the postoperative IOP (1 week) was statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 16.17 ± 4.65 mmHg, t = − 8.43, P < 0.05), and the difference between the preoperative IOP and the postoperative IOP (1 month) was also statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 14.63 ± 3.63 mmHg, t = − 8.38, P < 0.05). Duration of outpatient follow-up was 3 to 12 months. No complications, including exposed knots, loose sutures, decompensation of corneal endothelium, sympathetic ophthalmia, endophthalmitis and choroidal detachment, were reported. CONCLUSION: Continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30G needle is a safe and effective procedure with simple operation, little tissue damage and few complications.
format Online
Article
Text
id pubmed-6933675
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69336752019-12-30 Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation Li, Haibo Cai, Jinhong Li, Xiaofeng BMC Ophthalmol Research Article BACKGROUND: To investigate the efficacy and safety of continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30-gauge (G) needle. METHODS: Fifteen patients (15 eyes) with traumatic cyclodialysis cleft admitted to the ocular trauma department of our hospital from July 2014 to December 2018 were included in this study. After the bulbar conjunctiva corresponding to the ciliary body was incised along the corneal limbus, an incision was made along the corneal limbus on the opposite side. A 30G needle with a 10–0 suture entered the anterior chamber from the incision and passed through the ciliary body with clefts and the sclera to fixate the ciliary body on the sclera wall with continuous mattress suture. The best corrected visual acuity (BCVA) and intraocular pressure (IOP) were observed preoperatively and postoperatively. In vivo ultrasound biomicroscopy (UBM) was performed to observe closure of cyclodialysis cleft before and after surgery. RESULTS: Fifteen patients successfully underwent continuous mattress suture for repair of cyclodialysis cleft. No bleeding and suture breakage were reported during surgery. After surgery, the UBM during follow-up showed satisfactory closure of the cyclodialysis cleft. The BCVA and IOP were improved to different degrees. The difference between the preoperative IOP and the postoperative IOP (1 week) was statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 16.17 ± 4.65 mmHg, t = − 8.43, P < 0.05), and the difference between the preoperative IOP and the postoperative IOP (1 month) was also statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 14.63 ± 3.63 mmHg, t = − 8.38, P < 0.05). Duration of outpatient follow-up was 3 to 12 months. No complications, including exposed knots, loose sutures, decompensation of corneal endothelium, sympathetic ophthalmia, endophthalmitis and choroidal detachment, were reported. CONCLUSION: Continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30G needle is a safe and effective procedure with simple operation, little tissue damage and few complications. BioMed Central 2019-12-26 /pmc/articles/PMC6933675/ /pubmed/31878971 http://dx.doi.org/10.1186/s12886-019-1274-z Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Li, Haibo
Cai, Jinhong
Li, Xiaofeng
Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title_full Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title_fullStr Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title_full_unstemmed Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title_short Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
title_sort continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933675/
https://www.ncbi.nlm.nih.gov/pubmed/31878971
http://dx.doi.org/10.1186/s12886-019-1274-z
work_keys_str_mv AT lihaibo continuousabinternorepairingoftraumaticcyclodialysiscleftusinga30gaugeneedleinsevereoculartraumaaclinicalobservation
AT caijinhong continuousabinternorepairingoftraumaticcyclodialysiscleftusinga30gaugeneedleinsevereoculartraumaaclinicalobservation
AT lixiaofeng continuousabinternorepairingoftraumaticcyclodialysiscleftusinga30gaugeneedleinsevereoculartraumaaclinicalobservation