Cargando…
Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy
BACKGROUND: Lung cancer is a leading cause of morbidity and mortality worldwide. Radiotherapy for lung cancer is beneficial in both the radical and palliative settings, and technologic advances in recent years now afford an opportunity for this treatment to be more targeted than ever before. Althoug...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933676/ https://www.ncbi.nlm.nih.gov/pubmed/31878886 http://dx.doi.org/10.1186/s12880-019-0402-9 |
_version_ | 1783483255892213760 |
---|---|
author | Cao, Xiaohui Liu, Ming Zhai, Fushan Li, Nan Li, Feng Bao, Chaoen Liu, Yinliang Chen, Gang |
author_facet | Cao, Xiaohui Liu, Ming Zhai, Fushan Li, Nan Li, Feng Bao, Chaoen Liu, Yinliang Chen, Gang |
author_sort | Cao, Xiaohui |
collection | PubMed |
description | BACKGROUND: Lung cancer is a leading cause of morbidity and mortality worldwide. Radiotherapy for lung cancer is beneficial in both the radical and palliative settings, and technologic advances in recent years now afford an opportunity for this treatment to be more targeted than ever before. Although the delivery of more accurate forms of radiotherapy has minimized the risks of side-effects, how to utilize this treatment to optimize outcomes remains questionable. This study aimed to evaluate the accuracy of cone beam computed tomography (CBCT) image registration used in image-guided radiotherapy, providing reasonable guidance for clinic application of CBCT in lung cancer. METHODS: A total of 53 patients with lung carcinoma including 34 central and 19 peripheral lesions were collected in this study. Varian-IX linear accelerator on-board imaging (OBI) system was used to acquire CBCT scans in three-dimensional (3D) conformal radiotherapy before delivery. Different regions (whole lung/target/vertebrae/ipsilateral structure) were manually registered, and the position deviation and the registration time were analyzed. RESULTS: It was suggested that 34 cases belonged to central type and 19 cases belonged to peripheral type. The volume of left lung and right lung was 1242.98 ± 452.46 cc, 1689.69 ± 574.31 cc, respectively. Tumor size was 6.65 ± 3.87 cm in diameter, and 129.67 ± 136.48 cc in volume. The percentage of left lung and right lung was 6.17 ± 1.24%, 4.74 ± 0.38%, respectively. The position deviation value and absolute value of image registration methods of X, Y and Z axis were not significant (P > 0.05). However, registration time (s) between whole lung registration group, tumor registration group, vertebral body registration group, affected lung registration group, and artificial registration group, was 3.651 ± 0.867 s, 1.144 ± 0.129 s, 1.226 ± 0.126 s, 2.081 ± 0.427 s, 179.491 ± 71.975 s, respectively. The differences were significant (P < 0.05). The registration differences between small tumor group and large tumor group were not statistically significant (P > 0.05). CONCLUSION: The automatic image matching of OBI is accuracy and high reliability in recognition of offset error. Registering body or ipsilateral structure is recommended to be used in CBCT for lung cancer. |
format | Online Article Text |
id | pubmed-6933676 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-69336762019-12-30 Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy Cao, Xiaohui Liu, Ming Zhai, Fushan Li, Nan Li, Feng Bao, Chaoen Liu, Yinliang Chen, Gang BMC Med Imaging Research Article BACKGROUND: Lung cancer is a leading cause of morbidity and mortality worldwide. Radiotherapy for lung cancer is beneficial in both the radical and palliative settings, and technologic advances in recent years now afford an opportunity for this treatment to be more targeted than ever before. Although the delivery of more accurate forms of radiotherapy has minimized the risks of side-effects, how to utilize this treatment to optimize outcomes remains questionable. This study aimed to evaluate the accuracy of cone beam computed tomography (CBCT) image registration used in image-guided radiotherapy, providing reasonable guidance for clinic application of CBCT in lung cancer. METHODS: A total of 53 patients with lung carcinoma including 34 central and 19 peripheral lesions were collected in this study. Varian-IX linear accelerator on-board imaging (OBI) system was used to acquire CBCT scans in three-dimensional (3D) conformal radiotherapy before delivery. Different regions (whole lung/target/vertebrae/ipsilateral structure) were manually registered, and the position deviation and the registration time were analyzed. RESULTS: It was suggested that 34 cases belonged to central type and 19 cases belonged to peripheral type. The volume of left lung and right lung was 1242.98 ± 452.46 cc, 1689.69 ± 574.31 cc, respectively. Tumor size was 6.65 ± 3.87 cm in diameter, and 129.67 ± 136.48 cc in volume. The percentage of left lung and right lung was 6.17 ± 1.24%, 4.74 ± 0.38%, respectively. The position deviation value and absolute value of image registration methods of X, Y and Z axis were not significant (P > 0.05). However, registration time (s) between whole lung registration group, tumor registration group, vertebral body registration group, affected lung registration group, and artificial registration group, was 3.651 ± 0.867 s, 1.144 ± 0.129 s, 1.226 ± 0.126 s, 2.081 ± 0.427 s, 179.491 ± 71.975 s, respectively. The differences were significant (P < 0.05). The registration differences between small tumor group and large tumor group were not statistically significant (P > 0.05). CONCLUSION: The automatic image matching of OBI is accuracy and high reliability in recognition of offset error. Registering body or ipsilateral structure is recommended to be used in CBCT for lung cancer. BioMed Central 2019-12-26 /pmc/articles/PMC6933676/ /pubmed/31878886 http://dx.doi.org/10.1186/s12880-019-0402-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Cao, Xiaohui Liu, Ming Zhai, Fushan Li, Nan Li, Feng Bao, Chaoen Liu, Yinliang Chen, Gang Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title | Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title_full | Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title_fullStr | Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title_full_unstemmed | Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title_short | Comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
title_sort | comparative evaluation of image registration methods with different interest regions in lung cancer radiotherapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933676/ https://www.ncbi.nlm.nih.gov/pubmed/31878886 http://dx.doi.org/10.1186/s12880-019-0402-9 |
work_keys_str_mv | AT caoxiaohui comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT liuming comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT zhaifushan comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT linan comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT lifeng comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT baochaoen comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT liuyinliang comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy AT chengang comparativeevaluationofimageregistrationmethodswithdifferentinterestregionsinlungcancerradiotherapy |