Evaluation of Electrocautery and Stainless Steel Scalpel in Oral Mucoperiosteal Incision for Mandibular Anterior Fracture
BACKGROUND: Traditionally, mucosal incisions are made by stainless steel scalpel due to its ease of use, accuracy, and minimal tissue damage effect, but these incisions are more bloody and painful. To obviate the inherent disadvantages of scalpel, surgical diathermy was introduced at the beginning o...
Autores principales: | Nagargoje, Gopal Lahudas, Badal, Sheeraz, Mohiuddin, Syed Ahmed, Balkunde, Arunachaleshwar Somnath, Jadhav, Swati Suresh, Bholane, Dnyandeep Ramkrushna |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933970/ https://www.ncbi.nlm.nih.gov/pubmed/31908999 http://dx.doi.org/10.4103/ams.ams_158_18 |
Ejemplares similares
-
Abdominal Wound Problems After Hysterectomy With
Electrocautery vs. Scalpel Subcutaneous Incision
por: Hemsell, David L., et al.
Publicado: (1993) -
The effects of scalpel, harmonic scalpel and monopolar electrocautery on the healing of colonic anastomosis after colonic resection
por: Karaca, Gökhan, et al.
Publicado: (2016) -
Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review
por: Pruksapong, Chatchai, et al.
Publicado: (2023) -
Comparison of Conventional Bipolar Electrocautery and Ultrasonic Harmonic Scalpel in Colorectal Cancer Surgeries
por: Kalari, Premchand, et al.
Publicado: (2022) -
Outcomes of Harmonic Scalpel and Electrocautery in Patients Who Underwent Modified Radical Mastectomy
por: Memon, Farhana, et al.
Publicado: (2020)