Cargando…
Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures
Interventional magnetic resonance imaging (MRI) procedures promise to open-up new vistas regarding clinically relevant diagnostic and/or therapeutic procedures in the field of cardiology. However, a number of major limitations and challenges regarding interventional cardiovascular magnetic resonance...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6934499/ https://www.ncbi.nlm.nih.gov/pubmed/31882762 http://dx.doi.org/10.1038/s41598-019-56506-8 |
_version_ | 1783483396577558528 |
---|---|
author | Bietenbeck, Michael Florian, Anca Chatzantonis, Grigorios Meier, Claudia Korthals, Dennis Martens, Sven Yilmaz, Ali |
author_facet | Bietenbeck, Michael Florian, Anca Chatzantonis, Grigorios Meier, Claudia Korthals, Dennis Martens, Sven Yilmaz, Ali |
author_sort | Bietenbeck, Michael |
collection | PubMed |
description | Interventional magnetic resonance imaging (MRI) procedures promise to open-up new vistas regarding clinically relevant diagnostic and/or therapeutic procedures in the field of cardiology. However, a number of major limitations and challenges regarding interventional cardiovascular magnetic resonance (CMR) procedures still delay their translation from pre-clinical studies to human application. A CMR-conditional cardiac phantom was constructed using MR-safe or -conditional materials only that is based on a unique modular composition allowing quick replacement of individual components. A maximal flow of 76 ml/sec in the aorta and 111 ml/sec in the pulmonary artery were measured, whereas the maximal flow velocity was 56 cm/sec and 89 cm/sec, respectively. A conventional wedge-pressure catheter was advanced over a MRI-conditional guidewire into the right ventricle and thereafter positioned in the pulmonary artery. Pulmonary artery pressure was measured, obtaining the following values for our cardiac phantom: max/min/mean = 16/10/12 mmHg. The presented CMR-conditional cardiac phantom is the first of its kind that does not only mimic cardiac mechanics with adjustable fluid pressure in a four chamber setup that is closely adapted to that of the human heart, but also enables introduction and testing of interventional tools such as guidewires and catheters. |
format | Online Article Text |
id | pubmed-6934499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-69344992019-12-29 Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures Bietenbeck, Michael Florian, Anca Chatzantonis, Grigorios Meier, Claudia Korthals, Dennis Martens, Sven Yilmaz, Ali Sci Rep Article Interventional magnetic resonance imaging (MRI) procedures promise to open-up new vistas regarding clinically relevant diagnostic and/or therapeutic procedures in the field of cardiology. However, a number of major limitations and challenges regarding interventional cardiovascular magnetic resonance (CMR) procedures still delay their translation from pre-clinical studies to human application. A CMR-conditional cardiac phantom was constructed using MR-safe or -conditional materials only that is based on a unique modular composition allowing quick replacement of individual components. A maximal flow of 76 ml/sec in the aorta and 111 ml/sec in the pulmonary artery were measured, whereas the maximal flow velocity was 56 cm/sec and 89 cm/sec, respectively. A conventional wedge-pressure catheter was advanced over a MRI-conditional guidewire into the right ventricle and thereafter positioned in the pulmonary artery. Pulmonary artery pressure was measured, obtaining the following values for our cardiac phantom: max/min/mean = 16/10/12 mmHg. The presented CMR-conditional cardiac phantom is the first of its kind that does not only mimic cardiac mechanics with adjustable fluid pressure in a four chamber setup that is closely adapted to that of the human heart, but also enables introduction and testing of interventional tools such as guidewires and catheters. Nature Publishing Group UK 2019-12-27 /pmc/articles/PMC6934499/ /pubmed/31882762 http://dx.doi.org/10.1038/s41598-019-56506-8 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Bietenbeck, Michael Florian, Anca Chatzantonis, Grigorios Meier, Claudia Korthals, Dennis Martens, Sven Yilmaz, Ali Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title | Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title_full | Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title_fullStr | Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title_full_unstemmed | Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title_short | Introduction of a CMR-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional CMR procedures |
title_sort | introduction of a cmr-conditional cardiac phantom simulating cardiac anatomy and function and enabling training of interventional cmr procedures |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6934499/ https://www.ncbi.nlm.nih.gov/pubmed/31882762 http://dx.doi.org/10.1038/s41598-019-56506-8 |
work_keys_str_mv | AT bietenbeckmichael introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT floriananca introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT chatzantonisgrigorios introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT meierclaudia introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT korthalsdennis introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT martenssven introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures AT yilmazali introductionofacmrconditionalcardiacphantomsimulatingcardiacanatomyandfunctionandenablingtrainingofinterventionalcmrprocedures |