Cargando…
Knot my problem: Overcoming transradial catheter complications
Not all complications from transradial access can be prevented, even with diligent patient selection and preprocedure planning. This brief visual report offers technical suggestions to reverse knots and kinks encountered during catheter manipulation for endovascular transradial cerebral procedures.
Autores principales: | Walker, Melanie, Levitt, Michael R., Ghodke, Basavaraj V. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6935611/ https://www.ncbi.nlm.nih.gov/pubmed/31893113 http://dx.doi.org/10.1002/ccr3.2537 |
Ejemplares similares
-
Three strikes? Failed vascular access in mechanical thrombectomy
por: Walker, Melanie, et al.
Publicado: (2020) -
Tying the knot: An uncommon complication
por: Boumpoulis, Konstantinos, et al.
Publicado: (2019) -
Guidewire knot formation with peripherally inserted central catheter
por: Saito, Hiroaki, et al.
Publicado: (2020) -
Complication of a Swan–Ganz catheter: an intravascular knot
por: Canitrot, Ronan, et al.
Publicado: (2023) -
Spasm, stenosis and shelves: balloon-assisted tracking techniques in endovascular interventions
por: Walker, Melanie, et al.
Publicado: (2020)