Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia
INTRODUCTION: Haemoglobin A(1C) (A(1C)), as a parameter of long-term glycaemic control, has been adopted to guide diabetic therapy all over the world. However, falsely high or low A(1C) could be troublesome in daily practice. CASE DESCRIPTION: A 75-year-old male diabetic patient affected by a reason...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SMC Media Srl
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6936916/ https://www.ncbi.nlm.nih.gov/pubmed/31893205 http://dx.doi.org/10.12890/2019_001338 |
_version_ | 1783483785250078720 |
---|---|
author | Fan, Frank S Chen, Chih-Hao Yang, Hui-Chun |
author_facet | Fan, Frank S Chen, Chih-Hao Yang, Hui-Chun |
author_sort | Fan, Frank S |
collection | PubMed |
description | INTRODUCTION: Haemoglobin A(1C) (A(1C)), as a parameter of long-term glycaemic control, has been adopted to guide diabetic therapy all over the world. However, falsely high or low A(1C) could be troublesome in daily practice. CASE DESCRIPTION: A 75-year-old male diabetic patient affected by a reasonably inferred life-long history of microcytic anaemia was found to have abnormally low A(1C) values in the previous 5 months. Subsequent laboratory assessment with brilliant cresyl blue staining and haemoglobin electrophoresis detected haemoglobin H disease as the underlying cause of both the microcytic anaemia and the disturbed A(1C) measurement. DISCUSSION: Enhanced erythrocyte destruction such as in haemoglobin H disease could explain a falsely decreased A(1C) level very well. Upon facing a questionable A(1C) value, physicians dealing with diabetes should consider the possibility of undiscovered underlying causes rather than too tightly glycaemic control. LEARNING POINTS: Haemoglobin A(1C) values lower than the normal range most likely do not mean too good a control of blood sugar in diabetic patients. Careful investigation to find the underlying causes is mandatory to provide well-qualified medical care. Various haemoglobinopathies with chronic haemolysis should be considered as the background reason, especially in an endemic area for thalassaemia. |
format | Online Article Text |
id | pubmed-6936916 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SMC Media Srl |
record_format | MEDLINE/PubMed |
spelling | pubmed-69369162019-12-31 Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia Fan, Frank S Chen, Chih-Hao Yang, Hui-Chun Eur J Case Rep Intern Med Articles INTRODUCTION: Haemoglobin A(1C) (A(1C)), as a parameter of long-term glycaemic control, has been adopted to guide diabetic therapy all over the world. However, falsely high or low A(1C) could be troublesome in daily practice. CASE DESCRIPTION: A 75-year-old male diabetic patient affected by a reasonably inferred life-long history of microcytic anaemia was found to have abnormally low A(1C) values in the previous 5 months. Subsequent laboratory assessment with brilliant cresyl blue staining and haemoglobin electrophoresis detected haemoglobin H disease as the underlying cause of both the microcytic anaemia and the disturbed A(1C) measurement. DISCUSSION: Enhanced erythrocyte destruction such as in haemoglobin H disease could explain a falsely decreased A(1C) level very well. Upon facing a questionable A(1C) value, physicians dealing with diabetes should consider the possibility of undiscovered underlying causes rather than too tightly glycaemic control. LEARNING POINTS: Haemoglobin A(1C) values lower than the normal range most likely do not mean too good a control of blood sugar in diabetic patients. Careful investigation to find the underlying causes is mandatory to provide well-qualified medical care. Various haemoglobinopathies with chronic haemolysis should be considered as the background reason, especially in an endemic area for thalassaemia. SMC Media Srl 2019-11-29 /pmc/articles/PMC6936916/ /pubmed/31893205 http://dx.doi.org/10.12890/2019_001338 Text en © EFIM 2019 This article is licensed under a Commons Attribution Non-Commercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Articles Fan, Frank S Chen, Chih-Hao Yang, Hui-Chun Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title | Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title_full | Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title_fullStr | Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title_full_unstemmed | Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title_short | Haemoglobin A(1C) Levels Constantly Below Lower Reference Limit in a Diabetic Patient With Microcytic Anaemia |
title_sort | haemoglobin a(1c) levels constantly below lower reference limit in a diabetic patient with microcytic anaemia |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6936916/ https://www.ncbi.nlm.nih.gov/pubmed/31893205 http://dx.doi.org/10.12890/2019_001338 |
work_keys_str_mv | AT fanfranks haemoglobina1clevelsconstantlybelowlowerreferencelimitinadiabeticpatientwithmicrocyticanaemia AT chenchihhao haemoglobina1clevelsconstantlybelowlowerreferencelimitinadiabeticpatientwithmicrocyticanaemia AT yanghuichun haemoglobina1clevelsconstantlybelowlowerreferencelimitinadiabeticpatientwithmicrocyticanaemia |