Cargando…

Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes

BACKGROUND: Application of scalp pins for craniotomy surgeries is a noxious stimulus, causing tachycardia and hypertension, resulting in increased cerebral blood flow and elevated intracranial pressure, hence measures to attenuate this will have beneficial role. AIMS: The aim is to compare the effec...

Descripción completa

Detalles Bibliográficos
Autores principales: Arunashree, S, Hosagoudar, Pradeep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6937886/
https://www.ncbi.nlm.nih.gov/pubmed/32009706
http://dx.doi.org/10.4103/aer.AER_107_19
_version_ 1783483958772629504
author Arunashree, S
Hosagoudar, Pradeep
author_facet Arunashree, S
Hosagoudar, Pradeep
author_sort Arunashree, S
collection PubMed
description BACKGROUND: Application of scalp pins for craniotomy surgeries is a noxious stimulus, causing tachycardia and hypertension, resulting in increased cerebral blood flow and elevated intracranial pressure, hence measures to attenuate this will have beneficial role. AIMS: The aim is to compare the effectiveness of scalp block (SB) to 4 μg.kg(-1) intravenous (i.v) fentanyl in attenuating hemodynamic response to scalp pin application in patients who underwent elective craniotomy under general anesthesia. SETTINGS AND DESIGN: The study design involves prospective, randomized study conducted at Tertiary care center/hospital. SUBJECTS AND METHODS: Forty-four American Society of Anesthesiologists physical status Classes l and II patients were randomly allocated into the following groups: Group-SB (n = 22) received SB using 0.25% injection bupivacaine and Group-F (n = 22) received 1 μg.kg(-1) i.v fentanyl. Patient's heart rate (HR) and mean arterial pressure (MAP) were recorded from the application of pins till 60 min and rescue analgesic/anesthetic agents and their dosage were noted. Statistical analysis was performed comparing HR and MAP changes to application of scalp pins. STATISTICAL ANALYSIS: Software developed by the Centre for Disease Control, Atlanta, namely Epidemiological Information Package 2010 was used to derive statistical variables. RESULTS: Patients were comparable in age, gender, hypertension as comorbidity, baseline HR, and MAP. Significant rise in HR was noted in Group-F till 20(th) min compared to Group-SB. MAP was high from application of pins till 60(th) min in Group-F compared to Group-SB. Requirement of rescue analgesics/anesthetics was high in Group-F compared to Group-SB. CONCLUSION: SB effectively attenuates hemodynamic response to application of scalp pins in patients undergoing elective craniotomy and reduces requirement of rescue analgesic and/or anesthetics.
format Online
Article
Text
id pubmed-6937886
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-69378862020-01-31 Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes Arunashree, S Hosagoudar, Pradeep Anesth Essays Res Original Article BACKGROUND: Application of scalp pins for craniotomy surgeries is a noxious stimulus, causing tachycardia and hypertension, resulting in increased cerebral blood flow and elevated intracranial pressure, hence measures to attenuate this will have beneficial role. AIMS: The aim is to compare the effectiveness of scalp block (SB) to 4 μg.kg(-1) intravenous (i.v) fentanyl in attenuating hemodynamic response to scalp pin application in patients who underwent elective craniotomy under general anesthesia. SETTINGS AND DESIGN: The study design involves prospective, randomized study conducted at Tertiary care center/hospital. SUBJECTS AND METHODS: Forty-four American Society of Anesthesiologists physical status Classes l and II patients were randomly allocated into the following groups: Group-SB (n = 22) received SB using 0.25% injection bupivacaine and Group-F (n = 22) received 1 μg.kg(-1) i.v fentanyl. Patient's heart rate (HR) and mean arterial pressure (MAP) were recorded from the application of pins till 60 min and rescue analgesic/anesthetic agents and their dosage were noted. Statistical analysis was performed comparing HR and MAP changes to application of scalp pins. STATISTICAL ANALYSIS: Software developed by the Centre for Disease Control, Atlanta, namely Epidemiological Information Package 2010 was used to derive statistical variables. RESULTS: Patients were comparable in age, gender, hypertension as comorbidity, baseline HR, and MAP. Significant rise in HR was noted in Group-F till 20(th) min compared to Group-SB. MAP was high from application of pins till 60(th) min in Group-F compared to Group-SB. Requirement of rescue analgesics/anesthetics was high in Group-F compared to Group-SB. CONCLUSION: SB effectively attenuates hemodynamic response to application of scalp pins in patients undergoing elective craniotomy and reduces requirement of rescue analgesic and/or anesthetics. Wolters Kluwer - Medknow 2019 2019-12-16 /pmc/articles/PMC6937886/ /pubmed/32009706 http://dx.doi.org/10.4103/aer.AER_107_19 Text en Copyright: © 2019 Anesthesia: Essays and Researches http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Arunashree, S
Hosagoudar, Pradeep
Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title_full Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title_fullStr Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title_full_unstemmed Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title_short Intravenous Fentanyl 4 μg per kg Administered before Scalp Pin Application is Inferior to Scalp Block in Preventing Hemodynamic Changes
title_sort intravenous fentanyl 4 μg per kg administered before scalp pin application is inferior to scalp block in preventing hemodynamic changes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6937886/
https://www.ncbi.nlm.nih.gov/pubmed/32009706
http://dx.doi.org/10.4103/aer.AER_107_19
work_keys_str_mv AT arunashrees intravenousfentanyl4mgperkgadministeredbeforescalppinapplicationisinferiortoscalpblockinpreventinghemodynamicchanges
AT hosagoudarpradeep intravenousfentanyl4mgperkgadministeredbeforescalppinapplicationisinferiortoscalpblockinpreventinghemodynamicchanges