Cargando…

Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails

OBJECTIVE: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. METH...

Descripción completa

Detalles Bibliográficos
Autores principales: Erden, Tunay, Kapicioglu, Mehmet, Demirtas, Abdullah, Bilsel, Kerem, Akpinar, Fuat, Kuduz, Hacer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish Association of Orthopaedics and Traumatology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6938903/
https://www.ncbi.nlm.nih.gov/pubmed/31562026
http://dx.doi.org/10.1016/j.aott.2019.08.003
_version_ 1783484126135844864
author Erden, Tunay
Kapicioglu, Mehmet
Demirtas, Abdullah
Bilsel, Kerem
Akpinar, Fuat
Kuduz, Hacer
author_facet Erden, Tunay
Kapicioglu, Mehmet
Demirtas, Abdullah
Bilsel, Kerem
Akpinar, Fuat
Kuduz, Hacer
author_sort Erden, Tunay
collection PubMed
description OBJECTIVE: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. METHODS: InSafeLOCK humeral nail system (group 1, TST, Istanbul, Turkey) and Expert humeral nail system (group 2, DePuy Synthes, Bettlach, Switzerland) of the same size (9 × 300 mm) were examined. In total, 24 fourth-generation humerus sawbones were used in the experiment. Osteotomy was performed at the humerus shaft, and a defect was created by removing 1 cm of bone. After pre-loading 5000 cycles at a frequency of 2 Hz and a force of 50–250 N for axial loading and 5000 torsion torques between 0.5 Nm and 6.5 Nm at a 2 Hz frequency for torsional loading, the failure load values of each load were recorded. Distal interlocking was performed with an endopin in group 1, while a double cortex screw was used in group 2. RESULTS: All samples successfully passed the cyclic loading. The initial and final stiffness values were similar between the groups after axial loading (p = 0.873 and p = 0.522, respectively). The mean axial failure load values in groups 1 and 2 were 2627 ± 164 N and 7141 ± 1491 N, respectively. A significant difference was found in the axial failure load values (p = 0.004). Significant differences were observed between the initial and final torsional stiffness between the two groups (p = 0.004 and p = 0.004, respectively). No significant difference was found in the failure load values after torsional loading (11791 ± 2055 N.mm and 16997 ± 5440 N.mm) (p = 0.055). CONCLUSION: These results provide a biomechanical demonstration of the adequate stability of both nails after axial and rotational loading. The reliability of the newly developed InSafeLOCK humeral nail system, which does not require fluoroscopic control and an additional incision for distal locking, supports its use in the clinic.
format Online
Article
Text
id pubmed-6938903
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Turkish Association of Orthopaedics and Traumatology
record_format MEDLINE/PubMed
spelling pubmed-69389032020-01-06 Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails Erden, Tunay Kapicioglu, Mehmet Demirtas, Abdullah Bilsel, Kerem Akpinar, Fuat Kuduz, Hacer Acta Orthop Traumatol Turc Research Article OBJECTIVE: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. METHODS: InSafeLOCK humeral nail system (group 1, TST, Istanbul, Turkey) and Expert humeral nail system (group 2, DePuy Synthes, Bettlach, Switzerland) of the same size (9 × 300 mm) were examined. In total, 24 fourth-generation humerus sawbones were used in the experiment. Osteotomy was performed at the humerus shaft, and a defect was created by removing 1 cm of bone. After pre-loading 5000 cycles at a frequency of 2 Hz and a force of 50–250 N for axial loading and 5000 torsion torques between 0.5 Nm and 6.5 Nm at a 2 Hz frequency for torsional loading, the failure load values of each load were recorded. Distal interlocking was performed with an endopin in group 1, while a double cortex screw was used in group 2. RESULTS: All samples successfully passed the cyclic loading. The initial and final stiffness values were similar between the groups after axial loading (p = 0.873 and p = 0.522, respectively). The mean axial failure load values in groups 1 and 2 were 2627 ± 164 N and 7141 ± 1491 N, respectively. A significant difference was found in the axial failure load values (p = 0.004). Significant differences were observed between the initial and final torsional stiffness between the two groups (p = 0.004 and p = 0.004, respectively). No significant difference was found in the failure load values after torsional loading (11791 ± 2055 N.mm and 16997 ± 5440 N.mm) (p = 0.055). CONCLUSION: These results provide a biomechanical demonstration of the adequate stability of both nails after axial and rotational loading. The reliability of the newly developed InSafeLOCK humeral nail system, which does not require fluoroscopic control and an additional incision for distal locking, supports its use in the clinic. Turkish Association of Orthopaedics and Traumatology 2019-11 2019-09-24 /pmc/articles/PMC6938903/ /pubmed/31562026 http://dx.doi.org/10.1016/j.aott.2019.08.003 Text en © 2019 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Erden, Tunay
Kapicioglu, Mehmet
Demirtas, Abdullah
Bilsel, Kerem
Akpinar, Fuat
Kuduz, Hacer
Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title_full Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title_fullStr Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title_full_unstemmed Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title_short Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
title_sort biomechanical comparison of humeral nails with different distal locking mechanisms: insafelock nails versus conventional locking nails
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6938903/
https://www.ncbi.nlm.nih.gov/pubmed/31562026
http://dx.doi.org/10.1016/j.aott.2019.08.003
work_keys_str_mv AT erdentunay biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails
AT kapicioglumehmet biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails
AT demirtasabdullah biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails
AT bilselkerem biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails
AT akpinarfuat biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails
AT kuduzhacer biomechanicalcomparisonofhumeralnailswithdifferentdistallockingmechanismsinsafelocknailsversusconventionallockingnails