Cargando…

Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair

OBJECTIVES: The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Micic, Ivan, Kholinne, Erica, Kwak, Jae-Man, Koh, Kyoung-Hwan, Jeon, In-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish Association of Orthopaedics and Traumatology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6938998/
https://www.ncbi.nlm.nih.gov/pubmed/31563430
http://dx.doi.org/10.1016/j.aott.2019.08.015
_version_ 1783484146595659776
author Micic, Ivan
Kholinne, Erica
Kwak, Jae-Man
Koh, Kyoung-Hwan
Jeon, In-Ho
author_facet Micic, Ivan
Kholinne, Erica
Kwak, Jae-Man
Koh, Kyoung-Hwan
Jeon, In-Ho
author_sort Micic, Ivan
collection PubMed
description OBJECTIVES: The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. METHODS: From July 2012 to July 2014, 50 patients [28 men and 22 women; mean age, 56.4 (range: 45–56) years] underwent arthroscopic rotator cuff repair for a medium-to large-size tear with double-row suture-bridge technique. The bioabsorbable anchors used in the medial row comprised hydroxyapatite-polylactic acid enantiomer, and the nonabsorbable anchors in the lateral row were polyetheretherketone (PEEK)-type anchors. All patients underwent MRI evaluation at 3, 6, and 12 months postoperatively to determine osteolysis and identify any retear. RESULTS: The incidences of osteolysis at 3, 6, and 12 months postoperatively were 1%, 4%, and 6% with nonabsorbable anchors and 13%, 29%, and 39% with bioabsorbable anchors, respectively. The incidences of osteolysis were significantly higher with the bioabsorbable anchors than with the nonabsorbable anchors (P < 0.005 for all three follow-ups). There was no significant difference between osteolysis and non-osteolysis groups regarding the retear rate or retear size (P = 0.189 and 0.069, respectively). CONCLUSIONS: Osteolysis was common around bioabsorbable anchors used for arthroscopic rotator cuff repair, and it also occurred around the PEEK-type nonabsorbable anchors. The incidence of osteolysis of nonabsorbable anchors was significantly lower than that of bioabsorbable anchors. Osteolysis did not significantly affect rotator cuff retear after arthroscopic repair with either bioabsorbable or nonabsorbable anchors. LEVEL OF EVIDENCE: Level III, Therapeutic Study.
format Online
Article
Text
id pubmed-6938998
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Turkish Association of Orthopaedics and Traumatology
record_format MEDLINE/PubMed
spelling pubmed-69389982020-01-06 Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair Micic, Ivan Kholinne, Erica Kwak, Jae-Man Koh, Kyoung-Hwan Jeon, In-Ho Acta Orthop Traumatol Turc Research Article OBJECTIVES: The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. METHODS: From July 2012 to July 2014, 50 patients [28 men and 22 women; mean age, 56.4 (range: 45–56) years] underwent arthroscopic rotator cuff repair for a medium-to large-size tear with double-row suture-bridge technique. The bioabsorbable anchors used in the medial row comprised hydroxyapatite-polylactic acid enantiomer, and the nonabsorbable anchors in the lateral row were polyetheretherketone (PEEK)-type anchors. All patients underwent MRI evaluation at 3, 6, and 12 months postoperatively to determine osteolysis and identify any retear. RESULTS: The incidences of osteolysis at 3, 6, and 12 months postoperatively were 1%, 4%, and 6% with nonabsorbable anchors and 13%, 29%, and 39% with bioabsorbable anchors, respectively. The incidences of osteolysis were significantly higher with the bioabsorbable anchors than with the nonabsorbable anchors (P < 0.005 for all three follow-ups). There was no significant difference between osteolysis and non-osteolysis groups regarding the retear rate or retear size (P = 0.189 and 0.069, respectively). CONCLUSIONS: Osteolysis was common around bioabsorbable anchors used for arthroscopic rotator cuff repair, and it also occurred around the PEEK-type nonabsorbable anchors. The incidence of osteolysis of nonabsorbable anchors was significantly lower than that of bioabsorbable anchors. Osteolysis did not significantly affect rotator cuff retear after arthroscopic repair with either bioabsorbable or nonabsorbable anchors. LEVEL OF EVIDENCE: Level III, Therapeutic Study. Turkish Association of Orthopaedics and Traumatology 2019-11 2019-09-25 /pmc/articles/PMC6938998/ /pubmed/31563430 http://dx.doi.org/10.1016/j.aott.2019.08.015 Text en © 2019 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Micic, Ivan
Kholinne, Erica
Kwak, Jae-Man
Koh, Kyoung-Hwan
Jeon, In-Ho
Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title_full Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title_fullStr Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title_full_unstemmed Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title_short Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
title_sort osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6938998/
https://www.ncbi.nlm.nih.gov/pubmed/31563430
http://dx.doi.org/10.1016/j.aott.2019.08.015
work_keys_str_mv AT micicivan osteolysisisobservedaroundbothbioabsorbableandnonabsorbableanchorsonserialmagneticresonanceimagesofpatientsundergoingarthroscopicrotatorcuffrepair
AT kholinneerica osteolysisisobservedaroundbothbioabsorbableandnonabsorbableanchorsonserialmagneticresonanceimagesofpatientsundergoingarthroscopicrotatorcuffrepair
AT kwakjaeman osteolysisisobservedaroundbothbioabsorbableandnonabsorbableanchorsonserialmagneticresonanceimagesofpatientsundergoingarthroscopicrotatorcuffrepair
AT kohkyounghwan osteolysisisobservedaroundbothbioabsorbableandnonabsorbableanchorsonserialmagneticresonanceimagesofpatientsundergoingarthroscopicrotatorcuffrepair
AT jeoninho osteolysisisobservedaroundbothbioabsorbableandnonabsorbableanchorsonserialmagneticresonanceimagesofpatientsundergoingarthroscopicrotatorcuffrepair