Cargando…
Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study
BACKGROUND: Alignment correction of the lower limb by medial open-wedge high tibial osteotomy (HTO) is an efficient technique, but loss of correction and hardware failure can occur owing to inadequate fixation. A surgical technique using opposite screw insertion was previously applied for salvage of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Chinese Speaking Orthopaedic Society
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939025/ https://www.ncbi.nlm.nih.gov/pubmed/31908931 http://dx.doi.org/10.1016/j.jot.2019.06.004 |
_version_ | 1783484152843075584 |
---|---|
author | Chieh-Szu Yang, Jesse Chen, Cheng-Fong Lee, Oscar K. |
author_facet | Chieh-Szu Yang, Jesse Chen, Cheng-Fong Lee, Oscar K. |
author_sort | Chieh-Szu Yang, Jesse |
collection | PubMed |
description | BACKGROUND: Alignment correction of the lower limb by medial open-wedge high tibial osteotomy (HTO) is an efficient technique, but loss of correction and hardware failure can occur owing to inadequate fixation. A surgical technique using opposite screw insertion was previously applied for salvage of the lateral hinge fracture, but evidence for its utility as a protective strategy was unclear. METHODS: Finite element models were reconstructed using artificial bone models, commercial bone plate, and locking screws in the HTO model. The 6.5-mm cancellous or 6.5/8.0-mm pretensioned lag screw was virtually inserted from the opposite cortex to the medial tibial plateau. Testing loads were applied for simulating standing and initial sit-to-stand postures. The axial displacement of the posteromedial tibial plateau, which represents the loss of the posteromedial tibial plateau in clinical observation, and stresses on the bone plate, locking screws, and opposite screws were evaluated. RESULTS: Pretensioned lag screw insertion effectively reduced the loss of posteromedial reduction compared with the HTO model without opposite screw insertion [6.5-mm lag screw, by 50.8% (standing)/56.3% (sit-to-stand); 8.0-mm lag screws, by 51.9% (standing)/57.5% (sit-to-stand); normalised by the performance in the intact model]. The noncompressed opposite cancellous screw slightly reduced the stresses on the bone plate and screws, but did not contribute to the control of reduction loss at the posteromedial tibial plateau. Stresses on screws were lower than those on the corresponding bone plates, so the risk of screw breakage may be low. CONCLUSION: The present study revealed that pretensioned opposite lag screw insertion is a simple and effective technique to improve the structural stability in medial open-wedge HTO. Further biomechanical and clinical verification will be required to enhance user confidence in this technique. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The efficacy and advantages of additional opposite lag screw insertion in medial wedge high tibial osteotomy surgery have been described in this current study by a virtual biomechanical evaluation. Basing on this observation, it would worth further clinical trials for clarification and verification in reality. |
format | Online Article Text |
id | pubmed-6939025 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Chinese Speaking Orthopaedic Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-69390252020-01-06 Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study Chieh-Szu Yang, Jesse Chen, Cheng-Fong Lee, Oscar K. J Orthop Translat Original Article BACKGROUND: Alignment correction of the lower limb by medial open-wedge high tibial osteotomy (HTO) is an efficient technique, but loss of correction and hardware failure can occur owing to inadequate fixation. A surgical technique using opposite screw insertion was previously applied for salvage of the lateral hinge fracture, but evidence for its utility as a protective strategy was unclear. METHODS: Finite element models were reconstructed using artificial bone models, commercial bone plate, and locking screws in the HTO model. The 6.5-mm cancellous or 6.5/8.0-mm pretensioned lag screw was virtually inserted from the opposite cortex to the medial tibial plateau. Testing loads were applied for simulating standing and initial sit-to-stand postures. The axial displacement of the posteromedial tibial plateau, which represents the loss of the posteromedial tibial plateau in clinical observation, and stresses on the bone plate, locking screws, and opposite screws were evaluated. RESULTS: Pretensioned lag screw insertion effectively reduced the loss of posteromedial reduction compared with the HTO model without opposite screw insertion [6.5-mm lag screw, by 50.8% (standing)/56.3% (sit-to-stand); 8.0-mm lag screws, by 51.9% (standing)/57.5% (sit-to-stand); normalised by the performance in the intact model]. The noncompressed opposite cancellous screw slightly reduced the stresses on the bone plate and screws, but did not contribute to the control of reduction loss at the posteromedial tibial plateau. Stresses on screws were lower than those on the corresponding bone plates, so the risk of screw breakage may be low. CONCLUSION: The present study revealed that pretensioned opposite lag screw insertion is a simple and effective technique to improve the structural stability in medial open-wedge HTO. Further biomechanical and clinical verification will be required to enhance user confidence in this technique. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The efficacy and advantages of additional opposite lag screw insertion in medial wedge high tibial osteotomy surgery have been described in this current study by a virtual biomechanical evaluation. Basing on this observation, it would worth further clinical trials for clarification and verification in reality. Chinese Speaking Orthopaedic Society 2019-08-07 /pmc/articles/PMC6939025/ /pubmed/31908931 http://dx.doi.org/10.1016/j.jot.2019.06.004 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Chieh-Szu Yang, Jesse Chen, Cheng-Fong Lee, Oscar K. Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title | Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title_full | Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title_fullStr | Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title_full_unstemmed | Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title_short | Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study |
title_sort | benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: a virtual biomechanical study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939025/ https://www.ncbi.nlm.nih.gov/pubmed/31908931 http://dx.doi.org/10.1016/j.jot.2019.06.004 |
work_keys_str_mv | AT chiehszuyangjesse benefitsofoppositescrewinsertiontechniqueinmedialopenwedgehightibialosteotomyavirtualbiomechanicalstudy AT chenchengfong benefitsofoppositescrewinsertiontechniqueinmedialopenwedgehightibialosteotomyavirtualbiomechanicalstudy AT leeoscark benefitsofoppositescrewinsertiontechniqueinmedialopenwedgehightibialosteotomyavirtualbiomechanicalstudy |