Cargando…

The supraglottic airway device as first line of management in anticipated difficult mask ventilation in the morbidly obese

BACKGROUND AND AIMS: Supraglottic airway devices (SGAs) are used to rescue difficult and failed mask ventilation (DMV). We aimed to use the SGA as first-line device, prior to obtaining a definitive airway and to find any predictors of difficulty for the same, in the morbidly obese patients. MATERIAL...

Descripción completa

Detalles Bibliográficos
Autores principales: Sinha, Aparna, Jayaraman, Lakshmi, Punhani, Dinesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939552/
https://www.ncbi.nlm.nih.gov/pubmed/31920242
http://dx.doi.org/10.4103/joacp.JOACP_159_19
Descripción
Sumario:BACKGROUND AND AIMS: Supraglottic airway devices (SGAs) are used to rescue difficult and failed mask ventilation (DMV). We aimed to use the SGA as first-line device, prior to obtaining a definitive airway and to find any predictors of difficulty for the same, in the morbidly obese patients. MATERIAL AND METHODS: Obese surgical patients [body mass index (BMI) >35 kg/m(2)] were investigated. Difficulties with bag mask ventilation (MV) was graded using the following scale: MV-1, one anesthesiologist unassisted could achieve MV and maintain SpO(2)>90%; MV-2, one additional anesthesiologist was needed to facilitate MV to achieve SpO(2)> 90%; MV-3, two additional anesthesiologists were needed for this purpose; and MV-3P, when a supraglottic device was required to ventilate and maintain SpO(2) more than 90%. Parameters studied were age, gender, neck circumference (NC), BMI, STOPBANG score, and safe apnea time (SAT). RESULTS: Logistic regression was performed for predictors of MV-3P; receiver operating characteristic curve was used to locate the best cut-off. Analysis of 834 morbidly obese patients revealed an incidence of MV 1/2/3/3-P as 16%/38%/27%/19%, respectively. DMV was associated with BMI ≥50 kg/m(2), NC ≥49.5 cm, and STOPBANG ≥6; P < 0.001. The mean SAT for a population with mean BMI 48 ± 8 kg/m(2) was 256 ± 66 s. The SAT showed inverse relation to BMI and NC. As per our results, the NC was the single most important predictor of MV-3P, with sensitivity 0.62 and specificity 0.85 at best cut-off 49.5 cm; P < 0.001. CONCLUSION: NC ≥49.5 cm is strongly associated with low SAT and need for SGA to achieve MV. SGA may provide safety for initial management following induction of anesthesia in this patient population.