Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study
BACKGROUND AND AIMS: CMAC video laryngoscope size 2 D-Blade has been recently introduced for management of pediatric difficult airway. Our primary outcome was to compare glottic view, intubation time, and ease of intubation with the size 2 Macintosh versus D-Blade of C-MAC video laryngoscope in simu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939578/ https://www.ncbi.nlm.nih.gov/pubmed/31920236 http://dx.doi.org/10.4103/joacp.JOACP_106_18 |
_version_ | 1783484229897682944 |
---|---|
author | Sinha, Renu Ray, Bikash Ranjan Sharma, Ankur Pandey, Ravinder Kumar Punj, Jyotsna Darlong, Vanlalnghaka Trikha, Anjan |
author_facet | Sinha, Renu Ray, Bikash Ranjan Sharma, Ankur Pandey, Ravinder Kumar Punj, Jyotsna Darlong, Vanlalnghaka Trikha, Anjan |
author_sort | Sinha, Renu |
collection | PubMed |
description | BACKGROUND AND AIMS: CMAC video laryngoscope size 2 D-Blade has been recently introduced for management of pediatric difficult airway. Our primary outcome was to compare glottic view, intubation time, and ease of intubation with the size 2 Macintosh versus D-Blade of C-MAC video laryngoscope in simulated cervical injury in children. MATERIAL AND METHODS: This randomized crossover study was conducted in a tertiary care hospital of Northern India. Forty children of 4–14 years of age were enrolled in this study. After induction of anesthesia, video laryngoscopy was performed either with size 2 CMAC Macintosh (group M) or D-Blade (group D) with manual in-line stabilization. After removal of the first blade, second video laryngoscopy was performed with the alternative blade. Endotracheal intubation was done with the second laryngoscopy. Best glottic view, time for best glottic view, and difficulty in blade insertion were recorded during both the video laryngoscopies. During second video laryngoscopy, difficulty of tube insertion and time for intubation were noted. RESULTS: The glottic view grade was significantly better in group D compared with the group M (P = 0.0002). Insertion of D-Blade was more difficult than Macintosh blade (P = 0.0007). There was no statistical difference in terms of time for best glottic view in group M and group D (13.40 ± 4.90 vs 13.62 ± 5.60 s) and endotracheal tube insertion time (24.80 ± 7.90 vs 27.90 ± 10.90 s), respectively. Number of intubation attempts was similar in both the groups. CONCLUSIONS: Size 2 D-Blade of C-MAC video laryngoscope provided a better glottic view in children with simulated cervical spine injury as compared with CMAC Macintosh blade. Success of intubation, intubation time, and ease of intubation were comparable with both the blades. |
format | Online Article Text |
id | pubmed-6939578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-69395782020-01-09 Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study Sinha, Renu Ray, Bikash Ranjan Sharma, Ankur Pandey, Ravinder Kumar Punj, Jyotsna Darlong, Vanlalnghaka Trikha, Anjan J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: CMAC video laryngoscope size 2 D-Blade has been recently introduced for management of pediatric difficult airway. Our primary outcome was to compare glottic view, intubation time, and ease of intubation with the size 2 Macintosh versus D-Blade of C-MAC video laryngoscope in simulated cervical injury in children. MATERIAL AND METHODS: This randomized crossover study was conducted in a tertiary care hospital of Northern India. Forty children of 4–14 years of age were enrolled in this study. After induction of anesthesia, video laryngoscopy was performed either with size 2 CMAC Macintosh (group M) or D-Blade (group D) with manual in-line stabilization. After removal of the first blade, second video laryngoscopy was performed with the alternative blade. Endotracheal intubation was done with the second laryngoscopy. Best glottic view, time for best glottic view, and difficulty in blade insertion were recorded during both the video laryngoscopies. During second video laryngoscopy, difficulty of tube insertion and time for intubation were noted. RESULTS: The glottic view grade was significantly better in group D compared with the group M (P = 0.0002). Insertion of D-Blade was more difficult than Macintosh blade (P = 0.0007). There was no statistical difference in terms of time for best glottic view in group M and group D (13.40 ± 4.90 vs 13.62 ± 5.60 s) and endotracheal tube insertion time (24.80 ± 7.90 vs 27.90 ± 10.90 s), respectively. Number of intubation attempts was similar in both the groups. CONCLUSIONS: Size 2 D-Blade of C-MAC video laryngoscope provided a better glottic view in children with simulated cervical spine injury as compared with CMAC Macintosh blade. Success of intubation, intubation time, and ease of intubation were comparable with both the blades. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6939578/ /pubmed/31920236 http://dx.doi.org/10.4103/joacp.JOACP_106_18 Text en Copyright: © 2019 Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Sinha, Renu Ray, Bikash Ranjan Sharma, Ankur Pandey, Ravinder Kumar Punj, Jyotsna Darlong, Vanlalnghaka Trikha, Anjan Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title | Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title_full | Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title_fullStr | Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title_full_unstemmed | Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title_short | Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study |
title_sort | comparison of the c-mac video laryngoscope size 2 macintosh blade with size 2 c-mac d-blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: a prospective randomized crossover study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939578/ https://www.ncbi.nlm.nih.gov/pubmed/31920236 http://dx.doi.org/10.4103/joacp.JOACP_106_18 |
work_keys_str_mv | AT sinharenu comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT raybikashranjan comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT sharmaankur comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT pandeyravinderkumar comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT punjjyotsna comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT darlongvanlalnghaka comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy AT trikhaanjan comparisonofthecmacvideolaryngoscopesize2macintoshbladewithsize2cmacdbladeforlaryngoscopyandendotrachealintubationinchildrenwithsimulatedcervicalspineinjuryaprospectiverandomizedcrossoverstudy |