Cargando…

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

PURPOSE: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT) (Siemens Healthineers, Erlange...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Dae-Kyo, Lee, Sam-Sun, Kim, Jo-Eun, Huh, Kyung-Hoe, Yi, Won-Jin, Heo, Min-Suk, Choi, Soon-Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6941831/
https://www.ncbi.nlm.nih.gov/pubmed/31915612
http://dx.doi.org/10.5624/isd.2019.49.4.273
_version_ 1783484605562617856
author Jeong, Dae-Kyo
Lee, Sam-Sun
Kim, Jo-Eun
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Choi, Soon-Chul
author_facet Jeong, Dae-Kyo
Lee, Sam-Sun
Kim, Jo-Eun
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Choi, Soon-Chul
author_sort Jeong, Dae-Kyo
collection PubMed
description PURPOSE: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT) (Siemens Healthineers, Erlangen, Germany). MATERIALS AND METHODS: A bone density calibration phantom with 3 HA inserts of different densities (CTWATER®; 0, 100, and 200 mg of HA/cm(3)) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. RESULTS: Hydroxyapatite density was strongly correlated with HU values (correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels (correlation coefficient= −0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU (P>0.05). CONCLUSION: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.
format Online
Article
Text
id pubmed-6941831
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-69418312020-01-08 Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT Jeong, Dae-Kyo Lee, Sam-Sun Kim, Jo-Eun Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Choi, Soon-Chul Imaging Sci Dent Original Article PURPOSE: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT) (Siemens Healthineers, Erlangen, Germany). MATERIALS AND METHODS: A bone density calibration phantom with 3 HA inserts of different densities (CTWATER®; 0, 100, and 200 mg of HA/cm(3)) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. RESULTS: Hydroxyapatite density was strongly correlated with HU values (correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels (correlation coefficient= −0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU (P>0.05). CONCLUSION: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT. Korean Academy of Oral and Maxillofacial Radiology 2019-12 2019-12-24 /pmc/articles/PMC6941831/ /pubmed/31915612 http://dx.doi.org/10.5624/isd.2019.49.4.273 Text en Copyright © 2019 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Dae-Kyo
Lee, Sam-Sun
Kim, Jo-Eun
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Choi, Soon-Chul
Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title_full Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title_fullStr Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title_full_unstemmed Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title_short Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT
title_sort effects of energy level, reconstruction kernel, and tube rotation time on hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy ct
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6941831/
https://www.ncbi.nlm.nih.gov/pubmed/31915612
http://dx.doi.org/10.5624/isd.2019.49.4.273
work_keys_str_mv AT jeongdaekyo effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT leesamsun effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT kimjoeun effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT huhkyunghoe effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT yiwonjin effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT heominsuk effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct
AT choisoonchul effectsofenergylevelreconstructionkernelandtuberotationtimeonhounsfieldunitsofhydroxyapatiteinvirtualmonochromaticimagesobtainedwithdualenergyct