Cargando…

Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator

INTRODUCTION: Several methods treating proximal interphalangeal joint (PIP) fracture dislocations have been established providing early joint mobilization. The aim of this study was to evaluate the clinical and radiological outcome of unstable fracture dislocations of the PIP treated with a paraboli...

Descripción completa

Detalles Bibliográficos
Autores principales: Kastenberger, T., Kaiser, P., Keller, M., Schmidle, G., Gabl, M., Arora, Rohit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942001/
https://www.ncbi.nlm.nih.gov/pubmed/31486856
http://dx.doi.org/10.1007/s00402-019-03275-8
_version_ 1783484634058719232
author Kastenberger, T.
Kaiser, P.
Keller, M.
Schmidle, G.
Gabl, M.
Arora, Rohit
author_facet Kastenberger, T.
Kaiser, P.
Keller, M.
Schmidle, G.
Gabl, M.
Arora, Rohit
author_sort Kastenberger, T.
collection PubMed
description INTRODUCTION: Several methods treating proximal interphalangeal joint (PIP) fracture dislocations have been established providing early joint mobilization. The aim of this study was to evaluate the clinical and radiological outcome of unstable fracture dislocations of the PIP treated with a parabolic dynamic external fixator consisting of two Kirschner (K)-wires. MATERIALS AND METHODS: Twenty-one patients who sustained a pilonoidal fracture of the PIP joint and were treated with a dynamic external fixator were evaluated retrospectively. The active range of motion, pain level, DASH score, Buck Gramcko Score, and the patient’s satisfaction and acceptance were assessed. X-ray images were evaluated for bone healing, joint alignment, and signs of osteoarthritis. RESULTS: Mean PIP joint range of motion was 76°. Patients showed very mild discomfort (mean 0.7), high patient satisfaction (mean 1.9), and a moderate acceptance (mean 2.7). The mean DASH score was 11.6 and the Buck Gramcko score 13. All patients showed bone healing. One patient suffered from a recurrent dislocation, and another a subluxation of the PIP joint while wearing the fixator. Both joints could be corrected by modifying the fixator under image intensifier. Twenty patients (95%) showed a concentric and stable aligned joint. Three patients showed an osteoarthritis stage 0, five stage 1, nine stage 2, three stage 3, and one stage 4 according to the Kellgran–Lawrence Score. CONCLUSION: The use of a parabolic dynamic external fixator constructed from two K-wires restores joint alignment and stability in unstable pilonoidal PIP joint disclocation fractures. It allows immediate PIP joint mobilization to avoid adhesions. Modifications of the radius of the parabolic construct within cases of postoperative malalignment, without anesthesia, can restore joint axis and malalignment. This fixator is a cost-effective alternative, showing a good clinical outcome.
format Online
Article
Text
id pubmed-6942001
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-69420012020-01-16 Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator Kastenberger, T. Kaiser, P. Keller, M. Schmidle, G. Gabl, M. Arora, Rohit Arch Orthop Trauma Surg Trauma Surgery INTRODUCTION: Several methods treating proximal interphalangeal joint (PIP) fracture dislocations have been established providing early joint mobilization. The aim of this study was to evaluate the clinical and radiological outcome of unstable fracture dislocations of the PIP treated with a parabolic dynamic external fixator consisting of two Kirschner (K)-wires. MATERIALS AND METHODS: Twenty-one patients who sustained a pilonoidal fracture of the PIP joint and were treated with a dynamic external fixator were evaluated retrospectively. The active range of motion, pain level, DASH score, Buck Gramcko Score, and the patient’s satisfaction and acceptance were assessed. X-ray images were evaluated for bone healing, joint alignment, and signs of osteoarthritis. RESULTS: Mean PIP joint range of motion was 76°. Patients showed very mild discomfort (mean 0.7), high patient satisfaction (mean 1.9), and a moderate acceptance (mean 2.7). The mean DASH score was 11.6 and the Buck Gramcko score 13. All patients showed bone healing. One patient suffered from a recurrent dislocation, and another a subluxation of the PIP joint while wearing the fixator. Both joints could be corrected by modifying the fixator under image intensifier. Twenty patients (95%) showed a concentric and stable aligned joint. Three patients showed an osteoarthritis stage 0, five stage 1, nine stage 2, three stage 3, and one stage 4 according to the Kellgran–Lawrence Score. CONCLUSION: The use of a parabolic dynamic external fixator constructed from two K-wires restores joint alignment and stability in unstable pilonoidal PIP joint disclocation fractures. It allows immediate PIP joint mobilization to avoid adhesions. Modifications of the radius of the parabolic construct within cases of postoperative malalignment, without anesthesia, can restore joint axis and malalignment. This fixator is a cost-effective alternative, showing a good clinical outcome. Springer Berlin Heidelberg 2019-09-05 2020 /pmc/articles/PMC6942001/ /pubmed/31486856 http://dx.doi.org/10.1007/s00402-019-03275-8 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Trauma Surgery
Kastenberger, T.
Kaiser, P.
Keller, M.
Schmidle, G.
Gabl, M.
Arora, Rohit
Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title_full Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title_fullStr Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title_full_unstemmed Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title_short Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
title_sort clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator
topic Trauma Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942001/
https://www.ncbi.nlm.nih.gov/pubmed/31486856
http://dx.doi.org/10.1007/s00402-019-03275-8
work_keys_str_mv AT kastenbergert clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator
AT kaiserp clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator
AT kellerm clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator
AT schmidleg clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator
AT gablm clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator
AT arorarohit clinicalandradiologicalmidtermoutcomeaftertreatmentofpilonoidalfracturedislocationsoftheproximalinterphalangealjointwithaparabolicdynamicexternalfixator