Cargando…

Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women

BACKGROUND: Adequate thyroid function is essential for normal growth and development of the fetus. Sonographic recognition of alterations in fetal thyroid dimensions may be the first sign of thyroid dysfunction, permitting early diagnosis and intervention. The main goal of this study was to build cu...

Descripción completa

Detalles Bibliográficos
Autores principales: Barbosa, R. M., Andrade, K. C., Silveira, C., Almeida, C. M., Souza, R. T., Oliveira, P. F, Cecatti, Jose Guilherme
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942710/
https://www.ncbi.nlm.nih.gov/pubmed/31930141
http://dx.doi.org/10.1155/2019/9524378
_version_ 1783484750340554752
author Barbosa, R. M.
Andrade, K. C.
Silveira, C.
Almeida, C. M.
Souza, R. T.
Oliveira, P. F
Cecatti, Jose Guilherme
author_facet Barbosa, R. M.
Andrade, K. C.
Silveira, C.
Almeida, C. M.
Souza, R. T.
Oliveira, P. F
Cecatti, Jose Guilherme
author_sort Barbosa, R. M.
collection PubMed
description BACKGROUND: Adequate thyroid function is essential for normal growth and development of the fetus. Sonographic recognition of alterations in fetal thyroid dimensions may be the first sign of thyroid dysfunction, permitting early diagnosis and intervention. The main goal of this study was to build curves with reference values for ultrasound measurements of the fetal thyroid from 14 to 40 weeks of gestation. METHODS: This is a prospective longitudinal study of 90 Brazilian pregnant women, complementary to a cohort multicentre study named “WHO multicentre study for the development of growth standards from fetal life to childhood: the fetal component.” Pregnant women without any pre-existing conditions that might affect fetal growth received antenatal care from the first trimester until childbirth, undergoing serial ultrasound evaluations of the fetus, including the thyroid. Longitudinal, anteroposterior, and transverse diameters of both thyroid lobes were measured in the fetus. Fetal thyroid lobe volume was also estimated. By quantile regression analysis, reference curves of measurements were fitted according to the gestational age. RESULTS: A reference standard of thyroid growth was defined during pregnancy by fitting curves of its measurements. Reference values for the 10(th), 50(th), and 90(th) centiles of fetal thyroid measurements (longitudinal, anteroposterior, transverse diameters, and lobe volume) were defined, from 14 to 40 weeks of gestation. CONCLUSION: We provided a reference curve of optimal thyroid development in a low-risk population that can be used as a standard of comparison to diagnose deviations from the norm. In addition, we demonstrated an alternative and simplified method for early recognition of thyroid morphological alterations by an individualized technique to evaluate the thyroid lobes.
format Online
Article
Text
id pubmed-6942710
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-69427102020-01-12 Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women Barbosa, R. M. Andrade, K. C. Silveira, C. Almeida, C. M. Souza, R. T. Oliveira, P. F Cecatti, Jose Guilherme Biomed Res Int Research Article BACKGROUND: Adequate thyroid function is essential for normal growth and development of the fetus. Sonographic recognition of alterations in fetal thyroid dimensions may be the first sign of thyroid dysfunction, permitting early diagnosis and intervention. The main goal of this study was to build curves with reference values for ultrasound measurements of the fetal thyroid from 14 to 40 weeks of gestation. METHODS: This is a prospective longitudinal study of 90 Brazilian pregnant women, complementary to a cohort multicentre study named “WHO multicentre study for the development of growth standards from fetal life to childhood: the fetal component.” Pregnant women without any pre-existing conditions that might affect fetal growth received antenatal care from the first trimester until childbirth, undergoing serial ultrasound evaluations of the fetus, including the thyroid. Longitudinal, anteroposterior, and transverse diameters of both thyroid lobes were measured in the fetus. Fetal thyroid lobe volume was also estimated. By quantile regression analysis, reference curves of measurements were fitted according to the gestational age. RESULTS: A reference standard of thyroid growth was defined during pregnancy by fitting curves of its measurements. Reference values for the 10(th), 50(th), and 90(th) centiles of fetal thyroid measurements (longitudinal, anteroposterior, transverse diameters, and lobe volume) were defined, from 14 to 40 weeks of gestation. CONCLUSION: We provided a reference curve of optimal thyroid development in a low-risk population that can be used as a standard of comparison to diagnose deviations from the norm. In addition, we demonstrated an alternative and simplified method for early recognition of thyroid morphological alterations by an individualized technique to evaluate the thyroid lobes. Hindawi 2019-12-17 /pmc/articles/PMC6942710/ /pubmed/31930141 http://dx.doi.org/10.1155/2019/9524378 Text en Copyright © 2019 R. M. Barbosa et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Barbosa, R. M.
Andrade, K. C.
Silveira, C.
Almeida, C. M.
Souza, R. T.
Oliveira, P. F
Cecatti, Jose Guilherme
Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title_full Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title_fullStr Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title_full_unstemmed Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title_short Ultrasound Measurements of Fetal Thyroid: Reference Ranges from a Cohort of Low-Risk Pregnant Women
title_sort ultrasound measurements of fetal thyroid: reference ranges from a cohort of low-risk pregnant women
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942710/
https://www.ncbi.nlm.nih.gov/pubmed/31930141
http://dx.doi.org/10.1155/2019/9524378
work_keys_str_mv AT barbosarm ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT andradekc ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT silveirac ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT almeidacm ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT souzart ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT oliveirapf ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen
AT cecattijoseguilherme ultrasoundmeasurementsoffetalthyroidreferencerangesfromacohortoflowriskpregnantwomen