Cargando…
Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology
Structural discontinuities characterize the implants produced directly from metal powders in 3D printing technology. Mainly, the surface defects should be subjected to procedures associated with surface layer modification (likewise shot peening) resulting in the increase of the implant service life...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942838/ https://www.ncbi.nlm.nih.gov/pubmed/31934324 http://dx.doi.org/10.1155/2019/8169538 |
_version_ | 1783484781342752768 |
---|---|
author | Żebrowski, Remigiusz Walczak, Mariusz Korga, Agnieszka Iwan, Magdalena Szala, Mirosław |
author_facet | Żebrowski, Remigiusz Walczak, Mariusz Korga, Agnieszka Iwan, Magdalena Szala, Mirosław |
author_sort | Żebrowski, Remigiusz |
collection | PubMed |
description | Structural discontinuities characterize the implants produced directly from metal powders in 3D printing technology. Mainly, the surface defects should be subjected to procedures associated with surface layer modification (likewise shot peening) resulting in the increase of the implant service life maintaining optimal biocompatibility. Therefore, the purpose of the present study was to investigate the effect of type of shot used for the peening process on the Ti-6Al-4V implants functional properties as well as the biological properties. The components were produced by DMLS (direct metal laser sintering) additive technology. The surfaces of titanium specimens have been subjected to the shot peening process by means of three different shots, i.e., CrNi steel shot, crushed nut shells, and ceramic balls shot. Then, the specimens have been subjected to profilometric analysis, microhardness tests, and static strength testing as well as to the assessment of biocompatibility in respect of cytotoxicity using human BJ fibroblasts. The shot peening process causes the strengthening of surface layer and the increase of strength parameters. Furthermore, the test results indicate good biocompatibility of surfaces being tested, and the effect of shot peening process on the titanium alloy cytotoxicity is acceptable. At the same time, most favourable behaviour in respect of cytotoxicity has been found in the case of surfaces modified by means of ceramic balls > nut shells > CrNi steel shot correspondingly. |
format | Online Article Text |
id | pubmed-6942838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-69428382020-01-13 Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology Żebrowski, Remigiusz Walczak, Mariusz Korga, Agnieszka Iwan, Magdalena Szala, Mirosław J Healthc Eng Research Article Structural discontinuities characterize the implants produced directly from metal powders in 3D printing technology. Mainly, the surface defects should be subjected to procedures associated with surface layer modification (likewise shot peening) resulting in the increase of the implant service life maintaining optimal biocompatibility. Therefore, the purpose of the present study was to investigate the effect of type of shot used for the peening process on the Ti-6Al-4V implants functional properties as well as the biological properties. The components were produced by DMLS (direct metal laser sintering) additive technology. The surfaces of titanium specimens have been subjected to the shot peening process by means of three different shots, i.e., CrNi steel shot, crushed nut shells, and ceramic balls shot. Then, the specimens have been subjected to profilometric analysis, microhardness tests, and static strength testing as well as to the assessment of biocompatibility in respect of cytotoxicity using human BJ fibroblasts. The shot peening process causes the strengthening of surface layer and the increase of strength parameters. Furthermore, the test results indicate good biocompatibility of surfaces being tested, and the effect of shot peening process on the titanium alloy cytotoxicity is acceptable. At the same time, most favourable behaviour in respect of cytotoxicity has been found in the case of surfaces modified by means of ceramic balls > nut shells > CrNi steel shot correspondingly. Hindawi 2019-12-19 /pmc/articles/PMC6942838/ /pubmed/31934324 http://dx.doi.org/10.1155/2019/8169538 Text en Copyright © 2019 Remigiusz Żebrowski et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Żebrowski, Remigiusz Walczak, Mariusz Korga, Agnieszka Iwan, Magdalena Szala, Mirosław Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title | Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title_full | Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title_fullStr | Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title_full_unstemmed | Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title_short | Effect of Shot Peening on the Mechanical Properties and Cytotoxicity Behaviour of Titanium Implants Produced by 3D Printing Technology |
title_sort | effect of shot peening on the mechanical properties and cytotoxicity behaviour of titanium implants produced by 3d printing technology |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6942838/ https://www.ncbi.nlm.nih.gov/pubmed/31934324 http://dx.doi.org/10.1155/2019/8169538 |
work_keys_str_mv | AT zebrowskiremigiusz effectofshotpeeningonthemechanicalpropertiesandcytotoxicitybehaviouroftitaniumimplantsproducedby3dprintingtechnology AT walczakmariusz effectofshotpeeningonthemechanicalpropertiesandcytotoxicitybehaviouroftitaniumimplantsproducedby3dprintingtechnology AT korgaagnieszka effectofshotpeeningonthemechanicalpropertiesandcytotoxicitybehaviouroftitaniumimplantsproducedby3dprintingtechnology AT iwanmagdalena effectofshotpeeningonthemechanicalpropertiesandcytotoxicitybehaviouroftitaniumimplantsproducedby3dprintingtechnology AT szalamirosław effectofshotpeeningonthemechanicalpropertiesandcytotoxicitybehaviouroftitaniumimplantsproducedby3dprintingtechnology |