Cargando…

24-hour Intraocular pressure monitoring: the way ahead

Aim: Large diurnal intraocular pressure (IOP) fluctuation is a single most independent risk factor for glaucoma progression besides raised IOP. The major limitation of Goldman applanation tonometer (GAT) is its inability to measure night IOP without disturbing the patient’s sleep. We discussed the m...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhartiya, Shibal, Gangwani, Meenakshi, Kalra, R. Balwant, Aggarwal, Anand, Gagrani, Meghal, Sirish, Kumar Namagiri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Romanian Society of Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6943292/
https://www.ncbi.nlm.nih.gov/pubmed/31915728
Descripción
Sumario:Aim: Large diurnal intraocular pressure (IOP) fluctuation is a single most independent risk factor for glaucoma progression besides raised IOP. The major limitation of Goldman applanation tonometer (GAT) is its inability to measure night IOP without disturbing the patient’s sleep. We discussed the methods available for the 24-hour IOP monitoring and its relevance in glaucoma. Methods: A PUBMED search was performed using the 24 Hour tonometry, newer tonometry devices, contact lens sensors, as keywords and all relevant articles were studied. Results and Conclusion: A number of methods are available for the 24 hour IOP monitoring. These devices allow home monitoring of IOP without affecting the daily routine. These devices, like Rebound tonometry, Contact lens sensor (CLS), etc., were briefly discussed. Triggerfish is one CLS device that has the capability to measure IOP without affecting the patient’s sleep. Besides being safe and easily tolerable, it has shown reproducible results with other tonometry methods. Triggerfish has also been proven the device of choice in measuring IOP in different glaucoma subtypes and determining the efficacy of treatment in them, the only challenge being that it presently provides data on relative IOP rather than absolute IOP. With future research, triggerfish CLS can become an important device to measure the 24 hour IOP values especially in patients whose office measured IOPs seemingly fit in patient’s target range but still the patients’ disease shows glaucomatous progression. The utility of this device in relation to progressive vision loss is a matter of future study. Abbreviations: CCT = Central Corneal Thickness; CLS = Contact lens sensor; GAT = Goldmann Applanation Tonometer; IOP = Intraocular Pressure; NTG = Normal Tension Glaucoma; PACG = Primary angle closure glaucoma; POAG = Primary open angle glaucoma; VAS = Visual Analogue Score