Cargando…

Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus

BACKGROUND: In general, radiotherapy treatment planning is performed using the virtual bolus. It is necessary to investigate physical bolus in comparison to virtual one. OBJECTIVES: In the present study, first, radiological properties of superflab Gel bolus and Paraffin wax bolus was investigated in...

Descripción completa

Detalles Bibliográficos
Autores principales: Verma, T. R., Painuly, N. K., Tyagi, M., Johny, D., Gupta, R., Bhatt, M. L. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6943845/
https://www.ncbi.nlm.nih.gov/pubmed/32039093
http://dx.doi.org/10.31661/jbpe.v0i0.1177
_version_ 1783484960274907136
author Verma, T. R.
Painuly, N. K.
Tyagi, M.
Johny, D.
Gupta, R.
Bhatt, M. L. B.
author_facet Verma, T. R.
Painuly, N. K.
Tyagi, M.
Johny, D.
Gupta, R.
Bhatt, M. L. B.
author_sort Verma, T. R.
collection PubMed
description BACKGROUND: In general, radiotherapy treatment planning is performed using the virtual bolus. It is necessary to investigate physical bolus in comparison to virtual one. OBJECTIVES: In the present study, first, radiological properties of superflab Gel bolus and Paraffin wax bolus was investigated in terms of their relative electron density. Then, dosimetric performance of both the bolus (i.e. Gel and Parafin wax) was compared with Virtual bolus MATERIAL AND METHODS: In This experimental study, the radiological property of Wax and Gel boluses was investigated using two methods. In one, the relative electron density of both the Gel and Wax boluses was calculated by measuring their linear attenuation coefficient where in another method relative electron density was calculated by recording their CT No directly from their CT scan. Later CT scan of solid water slab phantom (dimension 30x30x15 cm(3)), with physical boluses (i.e. Gel and Wax bolus) of appropriate thicknesses required to deliver a dose of 200 cGy at D(max) using 4 MV, 6 MV and 15 MV photon beams, was taken. These CT data sets were retrieved to TPS. A plan was done to deliver a dose of 200 cGy at D(max) using Single 4 MV, 6 MV and 15 MV photon beams. Dose at depths D(max), 1 cm, 2 cm, 3 cm, 4 cm and 5 cm was recorded. Using this similar method, doses at depths viz D(max), 1 cm, 2 cm, 3 cm, 4 cm and 5 cm was recorded for the Gel and Wax boluses. The differences in dose of gel and wax bolus from virtual bolus were recorded for comparison of their dosimetric performance. RESULTS: The measured (calculated) relative electron density of wax and Gel bolus was found to be 0.958 (0.926) and 0.923 (0.907), respectively. Variation in dosimetric performance of Gel and Wax with reference to Virtual bolus was studied. However, on average, Gel bolus was more consistent with virtual bolus. CONCLUSION: To avoid any dose difference between, delivered (using physical bolus) and planned (using virtual bolus), the physical boluses should be investigated for their dosimetric performance in comparison to virtual bolus. The results obtained and methodology used in this study can be applied in routine radiotherapy practices
format Online
Article
Text
id pubmed-6943845
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-69438452020-02-07 Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus Verma, T. R. Painuly, N. K. Tyagi, M. Johny, D. Gupta, R. Bhatt, M. L. B. J Biomed Phys Eng Original Article BACKGROUND: In general, radiotherapy treatment planning is performed using the virtual bolus. It is necessary to investigate physical bolus in comparison to virtual one. OBJECTIVES: In the present study, first, radiological properties of superflab Gel bolus and Paraffin wax bolus was investigated in terms of their relative electron density. Then, dosimetric performance of both the bolus (i.e. Gel and Parafin wax) was compared with Virtual bolus MATERIAL AND METHODS: In This experimental study, the radiological property of Wax and Gel boluses was investigated using two methods. In one, the relative electron density of both the Gel and Wax boluses was calculated by measuring their linear attenuation coefficient where in another method relative electron density was calculated by recording their CT No directly from their CT scan. Later CT scan of solid water slab phantom (dimension 30x30x15 cm(3)), with physical boluses (i.e. Gel and Wax bolus) of appropriate thicknesses required to deliver a dose of 200 cGy at D(max) using 4 MV, 6 MV and 15 MV photon beams, was taken. These CT data sets were retrieved to TPS. A plan was done to deliver a dose of 200 cGy at D(max) using Single 4 MV, 6 MV and 15 MV photon beams. Dose at depths D(max), 1 cm, 2 cm, 3 cm, 4 cm and 5 cm was recorded. Using this similar method, doses at depths viz D(max), 1 cm, 2 cm, 3 cm, 4 cm and 5 cm was recorded for the Gel and Wax boluses. The differences in dose of gel and wax bolus from virtual bolus were recorded for comparison of their dosimetric performance. RESULTS: The measured (calculated) relative electron density of wax and Gel bolus was found to be 0.958 (0.926) and 0.923 (0.907), respectively. Variation in dosimetric performance of Gel and Wax with reference to Virtual bolus was studied. However, on average, Gel bolus was more consistent with virtual bolus. CONCLUSION: To avoid any dose difference between, delivered (using physical bolus) and planned (using virtual bolus), the physical boluses should be investigated for their dosimetric performance in comparison to virtual bolus. The results obtained and methodology used in this study can be applied in routine radiotherapy practices Shiraz University of Medical Sciences 2019-12-01 /pmc/articles/PMC6943845/ /pubmed/32039093 http://dx.doi.org/10.31661/jbpe.v0i0.1177 Text en Copyright: © Shiraz University of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Verma, T. R.
Painuly, N. K.
Tyagi, M.
Johny, D.
Gupta, R.
Bhatt, M. L. B.
Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title_full Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title_fullStr Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title_full_unstemmed Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title_short Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
title_sort validation of the gel & wax boluses and comparison of their dosimetric performance with virtual bolus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6943845/
https://www.ncbi.nlm.nih.gov/pubmed/32039093
http://dx.doi.org/10.31661/jbpe.v0i0.1177
work_keys_str_mv AT vermatr validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus
AT painulynk validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus
AT tyagim validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus
AT johnyd validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus
AT guptar validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus
AT bhattmlb validationofthegelwaxbolusesandcomparisonoftheirdosimetricperformancewithvirtualbolus