Cargando…
Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant)
RATIONALE: Galeazzi fractures are uncommon, and are less common in children than in adults. Galeazzi-equivalent fractures, a variant of the classic Galeazzi fractures, mostly occur in children or adolescents. Galeazzi equivalent fractures may commonly accompany distal radial fractures or injury of t...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946214/ https://www.ncbi.nlm.nih.gov/pubmed/31876721 http://dx.doi.org/10.1097/MD.0000000000018429 |
_version_ | 1783485312969736192 |
---|---|
author | Chae, Seung Bum Kwon, Jae Bum |
author_facet | Chae, Seung Bum Kwon, Jae Bum |
author_sort | Chae, Seung Bum |
collection | PubMed |
description | RATIONALE: Galeazzi fractures are uncommon, and are less common in children than in adults. Galeazzi-equivalent fractures, a variant of the classic Galeazzi fractures, mostly occur in children or adolescents. Galeazzi equivalent fractures may commonly accompany distal radial fractures or injury of the epiphyseal plate of the distal ulna. PATIENT CONCERNS: A 13-year-old man visited our emergency department after stumbling over a rock. Manual reduction and splinting was already done in a nearby medical center. Plain radiographs revealed fractures in the distal radius and fracture of the ulnar epiphyseal plate. DIAGNOSIS: Plain radiographs showed Galeazzi-equivalent fracture. The result of primary closed reduction was not enough and there was still displacement of fracture. INTERVENTIONS: Anatomical reduction of distal radius was fixed with a plate and screws, and K-wires were inserted percutaneously for reduction and fixation of ulnar fracture. OUTCOMES: Complete bone union was achieved and normal range of motion is shown 2 years postoperatively. The patient is able to perform daily activities and sport activities without any signs of ulnar growth arrest. LESSONS: Open reduction is required in patients with malalignment, failure to reduce the DRUJ or maintain its reduction, or older ages which are hard to expect sufficient bone remodeling. |
format | Online Article Text |
id | pubmed-6946214 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-69462142020-01-31 Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) Chae, Seung Bum Kwon, Jae Bum Medicine (Baltimore) 7100 RATIONALE: Galeazzi fractures are uncommon, and are less common in children than in adults. Galeazzi-equivalent fractures, a variant of the classic Galeazzi fractures, mostly occur in children or adolescents. Galeazzi equivalent fractures may commonly accompany distal radial fractures or injury of the epiphyseal plate of the distal ulna. PATIENT CONCERNS: A 13-year-old man visited our emergency department after stumbling over a rock. Manual reduction and splinting was already done in a nearby medical center. Plain radiographs revealed fractures in the distal radius and fracture of the ulnar epiphyseal plate. DIAGNOSIS: Plain radiographs showed Galeazzi-equivalent fracture. The result of primary closed reduction was not enough and there was still displacement of fracture. INTERVENTIONS: Anatomical reduction of distal radius was fixed with a plate and screws, and K-wires were inserted percutaneously for reduction and fixation of ulnar fracture. OUTCOMES: Complete bone union was achieved and normal range of motion is shown 2 years postoperatively. The patient is able to perform daily activities and sport activities without any signs of ulnar growth arrest. LESSONS: Open reduction is required in patients with malalignment, failure to reduce the DRUJ or maintain its reduction, or older ages which are hard to expect sufficient bone remodeling. Wolters Kluwer Health 2019-12-27 /pmc/articles/PMC6946214/ /pubmed/31876721 http://dx.doi.org/10.1097/MD.0000000000018429 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 7100 Chae, Seung Bum Kwon, Jae Bum Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title | Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title_full | Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title_fullStr | Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title_full_unstemmed | Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title_short | Pronation type Galeazzi-equivalent fracture: A rare case report (CARE-compliant) |
title_sort | pronation type galeazzi-equivalent fracture: a rare case report (care-compliant) |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946214/ https://www.ncbi.nlm.nih.gov/pubmed/31876721 http://dx.doi.org/10.1097/MD.0000000000018429 |
work_keys_str_mv | AT chaeseungbum pronationtypegaleazziequivalentfractureararecasereportcarecompliant AT kwonjaebum pronationtypegaleazziequivalentfractureararecasereportcarecompliant |