Current port maintenance strategies are insufficient: View based on actual presentations of implanted ports

Nursing staff play a crucial role in maintaining a functional port. Nursing guidelines recommend standard maintenance with 10 ml irrigation without consideration for variations among patients and individual nursing staff. The aim of this study is to identify the efficacy of the current maintenance s...

Descripción completa

Detalles Bibliográficos
Autores principales: Chou, Pin-Li, Fu, Jui-Ying, Cheng, Chia-Hui, Chu, Yen, Wu, Ching-Feng, Ko, Po-Jen, Liu, Yun-Hen, Wu, Ching-Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946320/
https://www.ncbi.nlm.nih.gov/pubmed/31689833
http://dx.doi.org/10.1097/MD.0000000000017757
Descripción
Sumario:Nursing staff play a crucial role in maintaining a functional port. Nursing guidelines recommend standard maintenance with 10 ml irrigation without consideration for variations among patients and individual nursing staff. The aim of this study is to identify the efficacy of the current maintenance strategy and analyze the correlation between complications and actual port presentations, based on disassembled intravenous ports after removal from patients. We attempt to organize the information and propose a definite maintenance strategy. After treatment completion, or due to complications, 434 implanted intravenous ports were removed from patients. All ports were deconstructed to observe their actual presentations and were then analyzed in conjunction with medical records. The correlation between complications and actual presentations was analyzed. From March 2012 to December 2017, 434 implanted intravenous ports were removed from oncology patients after completion of treatment or catheter related complications. From the view of maintenance related presentations, injection chamber blood clot was highly correlated with chemotherapy completion (P < .001) and malfunction (P = .005), while tip blood clot (P = .043) was related with chemotherapy completion and catheter fibrin (P = .015) was related to malfunction. From the view of structure related presentations, broken catheter integrity was correlated to chemotherapy completion (P = .007), fracture (P < .001), and malfunction (P = .008). Compression groove was related to chemotherapy completion (P = .03) and broken catheter at protruding stud was related to fracture (P = .04), while diaphragm rupture was correlated to chemotherapy completion (P = .048) and malfunction. (P < .001). Current port maintenance is insufficient for ideal port maintenance, whereby maintenance-related presentations, including tip clot, catheter fibrin, and injection chamber blood clot were identified. We propose a recommended maintenance strategy based on our findings. Structure-related presentations, including broken catheter integrity, broken catheter at protruding stud and diaphragm rupture were seen in patients with longer implantation period. Removal of the implanted port may be considered after 5 years if no disease relapse is noted.