Cargando…
Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model
BACKGROUND: Our previous three-dimensional finite element analysis found that posterior cruciate ligament (PCL) reconstruction in the modified tibial tunneling placement (MTT, 10 mm inferior and 5 mm lateral to the PCL anatomical insertion) could reduce the peak stress of the graft and may reduce th...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946428/ https://www.ncbi.nlm.nih.gov/pubmed/31876724 http://dx.doi.org/10.1097/MD.0000000000018439 |
_version_ | 1783485360646389760 |
---|---|
author | Wang, Zhiqiang Xiong, Yan Chen, Gang Tang, Xin Li, Qi Zhang, Zhong Shang, Xiaoke Yang, Yuan Sulaiman, Yaxiaer Li, Jian |
author_facet | Wang, Zhiqiang Xiong, Yan Chen, Gang Tang, Xin Li, Qi Zhang, Zhong Shang, Xiaoke Yang, Yuan Sulaiman, Yaxiaer Li, Jian |
author_sort | Wang, Zhiqiang |
collection | PubMed |
description | BACKGROUND: Our previous three-dimensional finite element analysis found that posterior cruciate ligament (PCL) reconstruction in the modified tibial tunneling placement (MTT, 10 mm inferior and 5 mm lateral to the PCL anatomical insertion) could reduce the peak stress of the graft and may reduce the killer turn. The purpose of the current study was to compare the biomechanical results between MTT and traditional tibial tunneling technique (TTT, PCL anatomical insertion) during transtibial PCL reconstruction. METHODS: Fifty-six 3D-printed tibia models and fresh mature porcine flexor digitorum tendons were studied. The PCL reconstruction specimens were randomly divided into TTT group and MTT group based on tibial tunnel placement. A 50 to 300 N cyclic loading was applied using a material testing system. Each specimen completed 2000 cycles at a rate of 200 mm/min and a loading frequency of 80 cycles/min. Load–displacement curves, failure mode, and graft displacement were recorded. Mean maximum contact pressure was measured using a pressure-sensitive film. After cyclic loading test, the surviving grafts were randomly assigned to load-to-failure group or Scanning Electron Microscopy (SEM) group. Ultimate failure load and the appearance of graft abrasion were recorded and analyzed. RESULT: During the cyclic loading test, 3 samples in the TTT group, and 2 in the MTT group were excluded because of the graft pullout during the test. Mean maximum contact pressure of killer turn was 9.30 ± 0.29 MPa in the TTT group and 7.27 ± 0.25 MPa in MTT group (P < .05). Mean graft displacement was 4.54 ± 0.23 mm in the TTT group and 3.37 ± 3.56 mm in the MTT group (P < .05). Maximum failure load was 1886.0 ± 41.83 N in the TTT group and 2019.30 ± 20.10 N in the MTT group (P < .05). The SEM analysis showed heavy abrasion and fiber discontinuity in graft in the TTT group, while it showed slight abrasion and fiber arrangement disorders in the MTT group. CONCLUSIONS: The MTT PCL reconstruction significantly reduced stress concentration and graft abrasion as compared with the TTT PCL reconstruction, and it may be a better choice for the reduction of “killer Turn” effect during transtibial PCL construction. |
format | Online Article Text |
id | pubmed-6946428 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-69464282020-01-31 Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model Wang, Zhiqiang Xiong, Yan Chen, Gang Tang, Xin Li, Qi Zhang, Zhong Shang, Xiaoke Yang, Yuan Sulaiman, Yaxiaer Li, Jian Medicine (Baltimore) 7000 BACKGROUND: Our previous three-dimensional finite element analysis found that posterior cruciate ligament (PCL) reconstruction in the modified tibial tunneling placement (MTT, 10 mm inferior and 5 mm lateral to the PCL anatomical insertion) could reduce the peak stress of the graft and may reduce the killer turn. The purpose of the current study was to compare the biomechanical results between MTT and traditional tibial tunneling technique (TTT, PCL anatomical insertion) during transtibial PCL reconstruction. METHODS: Fifty-six 3D-printed tibia models and fresh mature porcine flexor digitorum tendons were studied. The PCL reconstruction specimens were randomly divided into TTT group and MTT group based on tibial tunnel placement. A 50 to 300 N cyclic loading was applied using a material testing system. Each specimen completed 2000 cycles at a rate of 200 mm/min and a loading frequency of 80 cycles/min. Load–displacement curves, failure mode, and graft displacement were recorded. Mean maximum contact pressure was measured using a pressure-sensitive film. After cyclic loading test, the surviving grafts were randomly assigned to load-to-failure group or Scanning Electron Microscopy (SEM) group. Ultimate failure load and the appearance of graft abrasion were recorded and analyzed. RESULT: During the cyclic loading test, 3 samples in the TTT group, and 2 in the MTT group were excluded because of the graft pullout during the test. Mean maximum contact pressure of killer turn was 9.30 ± 0.29 MPa in the TTT group and 7.27 ± 0.25 MPa in MTT group (P < .05). Mean graft displacement was 4.54 ± 0.23 mm in the TTT group and 3.37 ± 3.56 mm in the MTT group (P < .05). Maximum failure load was 1886.0 ± 41.83 N in the TTT group and 2019.30 ± 20.10 N in the MTT group (P < .05). The SEM analysis showed heavy abrasion and fiber discontinuity in graft in the TTT group, while it showed slight abrasion and fiber arrangement disorders in the MTT group. CONCLUSIONS: The MTT PCL reconstruction significantly reduced stress concentration and graft abrasion as compared with the TTT PCL reconstruction, and it may be a better choice for the reduction of “killer Turn” effect during transtibial PCL construction. Wolters Kluwer Health 2019-12-27 /pmc/articles/PMC6946428/ /pubmed/31876724 http://dx.doi.org/10.1097/MD.0000000000018439 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | 7000 Wang, Zhiqiang Xiong, Yan Chen, Gang Tang, Xin Li, Qi Zhang, Zhong Shang, Xiaoke Yang, Yuan Sulaiman, Yaxiaer Li, Jian Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title | Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title_full | Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title_fullStr | Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title_full_unstemmed | Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title_short | Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “Killer Turn” in a biomechanical model |
title_sort | modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the “killer turn” in a biomechanical model |
topic | 7000 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946428/ https://www.ncbi.nlm.nih.gov/pubmed/31876724 http://dx.doi.org/10.1097/MD.0000000000018439 |
work_keys_str_mv | AT wangzhiqiang modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT xiongyan modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT chengang modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT tangxin modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT liqi modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT zhangzhong modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT shangxiaoke modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT yangyuan modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT sulaimanyaxiaer modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel AT lijian modifiedtibialtunnelplacementforsinglebundleposteriorcruciateligamentreconstructionreducesthekillerturninabiomechanicalmodel |