Feasibility and accuracy of real-time three-dimensional echocardiography in evaluating the aortic valve in children

BACKGROUND: Aortic valve assessment by 2D transthoracic echocardiography is a relatively complex task owing to the unique anatomical features of the left ventricular outflow tract and its dynamic nature. We aimed to evaluate the accuracy of 3D transthoracic echocardiography [3D TTE] in assessing the...

Descripción completa

Detalles Bibliográficos
Autores principales: Ezzeldin, Dina Adel, Roushdy, Alaa Mahmoud, Abdallah, Abdallah Ahmed, El Fiky, Azza Abdallah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946771/
https://www.ncbi.nlm.nih.gov/pubmed/31912327
http://dx.doi.org/10.1186/s43044-019-0037-8
Descripción
Sumario:BACKGROUND: Aortic valve assessment by 2D transthoracic echocardiography is a relatively complex task owing to the unique anatomical features of the left ventricular outflow tract and its dynamic nature. We aimed to evaluate the accuracy of 3D transthoracic echocardiography [3D TTE] in assessing the aortic valve in children. RESULTS: The first group included 11 males and six females, with a mean age of 5.76 ± 6.39 years. All of these patients had aortic valve disease with a bicuspid variant. The second group included seven males and seven females, with a mean age of 4.4 ± 4.05 years. All of these patients had normal aortic valve morphology and had another congenital cardiac anomaly. The aortic valve annulus was assessed using the three modalities; 2D, 3D echocardiography in the vertical and horizontal diameters, and angiography. The aortic valve area was measured by 2D and 3D echocardiography using multiplane reformatted mode. The results of the analysis were then compared. They revealed that 3D echocardiographic measurement of the aortic annulus (horizontal diameter) correlated better with angiography than 2D and 3D (vertical diameter) echocardiographic measurements. There was a significant difference between the aortic valve area measured by 2D echocardiography and that measured by 3D echocardiography among the two groups, 2D echocardiography seems to underestimate the true aortic valve area. CONCLUSION: The study concluded that 3D TTE with multiplane reformatted mode allows a more accurate assessment of the aortic valve when compared to 2D echocardiography and this correlates better with the angiographic findings.