Cargando…

Rotator Interval Plication: The “Seamster” Technique

The indications and best technique for plication of the rotator interval capsule, performed as a supplemental procedure at the time of arthroscopic shoulder stabilization, remain a controversial topic. There are currently no well-accepted surgical indication guidelines that have been established. Se...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Jace R., Field, Larry D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6948111/
https://www.ncbi.nlm.nih.gov/pubmed/31921580
http://dx.doi.org/10.1016/j.eats.2019.05.025
_version_ 1783485686625599488
author Smith, Jace R.
Field, Larry D.
author_facet Smith, Jace R.
Field, Larry D.
author_sort Smith, Jace R.
collection PubMed
description The indications and best technique for plication of the rotator interval capsule, performed as a supplemental procedure at the time of arthroscopic shoulder stabilization, remain a controversial topic. There are currently no well-accepted surgical indication guidelines that have been established. Several biomechanical studies, however, have demonstrated the important contribution of the rotator interval capsule to stability of the glenohumeral joint, and the utilization of rotator interval plication in patients with glenohumeral instability has been supported in several publications. The indications for and surgical steps to accomplish the arthroscopic “seamster” technique for rotator interval plication, used by the authors for >20 years, is described.
format Online
Article
Text
id pubmed-6948111
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-69481112020-01-09 Rotator Interval Plication: The “Seamster” Technique Smith, Jace R. Field, Larry D. Arthrosc Tech Technical Note The indications and best technique for plication of the rotator interval capsule, performed as a supplemental procedure at the time of arthroscopic shoulder stabilization, remain a controversial topic. There are currently no well-accepted surgical indication guidelines that have been established. Several biomechanical studies, however, have demonstrated the important contribution of the rotator interval capsule to stability of the glenohumeral joint, and the utilization of rotator interval plication in patients with glenohumeral instability has been supported in several publications. The indications for and surgical steps to accomplish the arthroscopic “seamster” technique for rotator interval plication, used by the authors for >20 years, is described. Elsevier 2019-09-19 /pmc/articles/PMC6948111/ /pubmed/31921580 http://dx.doi.org/10.1016/j.eats.2019.05.025 Text en © 2019 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Smith, Jace R.
Field, Larry D.
Rotator Interval Plication: The “Seamster” Technique
title Rotator Interval Plication: The “Seamster” Technique
title_full Rotator Interval Plication: The “Seamster” Technique
title_fullStr Rotator Interval Plication: The “Seamster” Technique
title_full_unstemmed Rotator Interval Plication: The “Seamster” Technique
title_short Rotator Interval Plication: The “Seamster” Technique
title_sort rotator interval plication: the “seamster” technique
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6948111/
https://www.ncbi.nlm.nih.gov/pubmed/31921580
http://dx.doi.org/10.1016/j.eats.2019.05.025
work_keys_str_mv AT smithjacer rotatorintervalplicationtheseamstertechnique
AT fieldlarryd rotatorintervalplicationtheseamstertechnique