Quantifying Subresolution 3D Morphology of Bone with Clinical Computed Tomography

The aim of this study was to quantify sub-resolution trabecular bone morphometrics, which are also related to osteoarthritis (OA), from clinical resolution cone beam computed tomography (CBCT). Samples (n = 53) were harvested from human tibiae (N = 4) and femora (N = 7). Grey-level co-occurrence mat...

Descripción completa

Detalles Bibliográficos
Autores principales: Karhula, S. S., Finnilä, M. A. J., Rytky, S. J. O., Cooper, D. M., Thevenot, J., Valkealahti, M., Pritzker, K. P. H., Haapea, M., Joukainen, A., Lehenkari, P., Kröger, H., Korhonen, R. K., Nieminen, H. J., Saarakkala, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6949315/
https://www.ncbi.nlm.nih.gov/pubmed/31583552
http://dx.doi.org/10.1007/s10439-019-02374-2
Descripción
Sumario:The aim of this study was to quantify sub-resolution trabecular bone morphometrics, which are also related to osteoarthritis (OA), from clinical resolution cone beam computed tomography (CBCT). Samples (n = 53) were harvested from human tibiae (N = 4) and femora (N = 7). Grey-level co-occurrence matrix (GLCM) texture and histogram-based parameters were calculated from CBCT imaged trabecular bone data, and compared with the morphometric parameters quantified from micro-computed tomography. As a reference for OA severity, histological sections were subjected to OARSI histopathological grading. GLCM and histogram parameters were correlated to bone morphometrics and OARSI individually. Furthermore, a statistical model of combined GLCM/histogram parameters was generated to estimate the bone morphometrics. Several individual histogram and GLCM parameters had strong associations with various bone morphometrics (|r| > 0.7). The most prominent correlation was observed between the histogram mean and bone volume fraction (r = 0.907). The statistical model combining GLCM and histogram-parameters resulted in even better association with bone volume fraction determined from CBCT data (adjusted R(2) change = 0.047). Histopathology showed mainly moderate associations with bone morphometrics (|r| > 0.4). In conclusion, we demonstrated that GLCM- and histogram-based parameters from CBCT imaged trabecular bone (ex vivo) are associated with sub-resolution morphometrics. Our results suggest that sub-resolution morphometrics can be estimated from clinical CBCT images, associations becoming even stronger when combining histogram and GLCM-based parameters. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10439-019-02374-2) contains supplementary material, which is available to authorized users.