Performance of the counter-torque technique in the explantation of nonmobile dental implants

BACKGROUND: The application of the counter-torque technique has been proposed as a conservative and atraumatic alternative for the explantation of nonmobile dental implants. The objective of this report is to assess the performance of this technique in a large number of patients. RESULTS: Three hund...

Descripción completa

Detalles Bibliográficos
Autores principales: Anitua, Eduardo, Fernandez-de-Retana, Sofia, Alkhraisat, Mohammad H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6949338/
https://www.ncbi.nlm.nih.gov/pubmed/31916016
http://dx.doi.org/10.1186/s40729-019-0197-z
_version_ 1783485903200583680
author Anitua, Eduardo
Fernandez-de-Retana, Sofia
Alkhraisat, Mohammad H.
author_facet Anitua, Eduardo
Fernandez-de-Retana, Sofia
Alkhraisat, Mohammad H.
author_sort Anitua, Eduardo
collection PubMed
description BACKGROUND: The application of the counter-torque technique has been proposed as a conservative and atraumatic alternative for the explantation of nonmobile dental implants. The objective of this report is to assess the performance of this technique in a large number of patients. RESULTS: Three hundred and fifty-five patients were treated for the explantation of 749 nonmobile dental implants. The explantations were performed by the application of counter-torque to break the bone-implant interface. Successful implant explantation was achieved in 98.4% of the implants. The frequency of complications was 1.3%, most commonly related to the appearance of fissure lines at the implant neck. CONCLUSIONS: The counter-torque technique has a high success rate but is not exempt from complications, although at a very low rate.
format Online
Article
Text
id pubmed-6949338
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-69493382020-01-23 Performance of the counter-torque technique in the explantation of nonmobile dental implants Anitua, Eduardo Fernandez-de-Retana, Sofia Alkhraisat, Mohammad H. Int J Implant Dent Short Report BACKGROUND: The application of the counter-torque technique has been proposed as a conservative and atraumatic alternative for the explantation of nonmobile dental implants. The objective of this report is to assess the performance of this technique in a large number of patients. RESULTS: Three hundred and fifty-five patients were treated for the explantation of 749 nonmobile dental implants. The explantations were performed by the application of counter-torque to break the bone-implant interface. Successful implant explantation was achieved in 98.4% of the implants. The frequency of complications was 1.3%, most commonly related to the appearance of fissure lines at the implant neck. CONCLUSIONS: The counter-torque technique has a high success rate but is not exempt from complications, although at a very low rate. Springer Berlin Heidelberg 2020-01-09 /pmc/articles/PMC6949338/ /pubmed/31916016 http://dx.doi.org/10.1186/s40729-019-0197-z Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Short Report
Anitua, Eduardo
Fernandez-de-Retana, Sofia
Alkhraisat, Mohammad H.
Performance of the counter-torque technique in the explantation of nonmobile dental implants
title Performance of the counter-torque technique in the explantation of nonmobile dental implants
title_full Performance of the counter-torque technique in the explantation of nonmobile dental implants
title_fullStr Performance of the counter-torque technique in the explantation of nonmobile dental implants
title_full_unstemmed Performance of the counter-torque technique in the explantation of nonmobile dental implants
title_short Performance of the counter-torque technique in the explantation of nonmobile dental implants
title_sort performance of the counter-torque technique in the explantation of nonmobile dental implants
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6949338/
https://www.ncbi.nlm.nih.gov/pubmed/31916016
http://dx.doi.org/10.1186/s40729-019-0197-z
work_keys_str_mv AT anituaeduardo performanceofthecountertorquetechniqueintheexplantationofnonmobiledentalimplants
AT fernandezderetanasofia performanceofthecountertorquetechniqueintheexplantationofnonmobiledentalimplants
AT alkhraisatmohammadh performanceofthecountertorquetechniqueintheexplantationofnonmobiledentalimplants