Cargando…
Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis
BACKGROUND: The purpose of this study was to compare the anatomical and visual outcomes of inverted internal limiting membrane (ILM) flap technique and internal limiting membrane peeling in large macular holes (MH). METHODS: Related studies were reviewed by searching electronic databases of Pubmed,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6950886/ https://www.ncbi.nlm.nih.gov/pubmed/31914954 http://dx.doi.org/10.1186/s12886-019-1271-2 |
_version_ | 1783486173883138048 |
---|---|
author | Shen, Yu Lin, Xiaoqin Zhang, Luyi Wu, Miaoqin |
author_facet | Shen, Yu Lin, Xiaoqin Zhang, Luyi Wu, Miaoqin |
author_sort | Shen, Yu |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to compare the anatomical and visual outcomes of inverted internal limiting membrane (ILM) flap technique and internal limiting membrane peeling in large macular holes (MH). METHODS: Related studies were reviewed by searching electronic databases of Pubmed, Embase, Cochrane Library. We searched for articles that compared inverted ILM flap technique with ILM peeling for large MH (> 400 μm). Double-arm meta-analysis was performed for the primary end point that was the rate of MH closure, and the secondary end point was postoperative visual acuity (VA). Heterogeneity, publication bias, sensitivity analysis and subgroup analysis were conducted to guarantee the statistical power. RESULTS: This review included eight studies involving 593 eyes, 4 randomized control trials and 4 retrospective studies. After sensitivity analysis for eliminating the heterogeneity of primary outcome, the pooled data showed the rate of MH closure with inverted ILM flap technique group was statistically significantly higher than ILM peeling group (odds ratio (OR) = 3.95, 95% confidence interval (CI) = 1.89 to 8.27; P = 0.0003). At the follow-up duration of 3 months, postoperative VA was significantly better in the group of inverted ILM flap than ILM peeling (mean difference (MD) = − 0.16, 95% CI = − 0.23 to 0.09; P < 0.00001). However, there was no difference in visual outcomes between the two groups of different surgical treatments at relatively long-term follow-up over 6 months (MD = 0.01, 95% CI = − 0.12 to 0.15; P = 0.86). CONCLUSION: Vitrectomy with inverted ILM flap technique had a better anatomical outcome than ILM peeling. Flap technique also had a signifcant visual gain in the short term, but the limitations in visual recovery at a longer follow-up was found. |
format | Online Article Text |
id | pubmed-6950886 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-69508862020-01-09 Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis Shen, Yu Lin, Xiaoqin Zhang, Luyi Wu, Miaoqin BMC Ophthalmol Research Article BACKGROUND: The purpose of this study was to compare the anatomical and visual outcomes of inverted internal limiting membrane (ILM) flap technique and internal limiting membrane peeling in large macular holes (MH). METHODS: Related studies were reviewed by searching electronic databases of Pubmed, Embase, Cochrane Library. We searched for articles that compared inverted ILM flap technique with ILM peeling for large MH (> 400 μm). Double-arm meta-analysis was performed for the primary end point that was the rate of MH closure, and the secondary end point was postoperative visual acuity (VA). Heterogeneity, publication bias, sensitivity analysis and subgroup analysis were conducted to guarantee the statistical power. RESULTS: This review included eight studies involving 593 eyes, 4 randomized control trials and 4 retrospective studies. After sensitivity analysis for eliminating the heterogeneity of primary outcome, the pooled data showed the rate of MH closure with inverted ILM flap technique group was statistically significantly higher than ILM peeling group (odds ratio (OR) = 3.95, 95% confidence interval (CI) = 1.89 to 8.27; P = 0.0003). At the follow-up duration of 3 months, postoperative VA was significantly better in the group of inverted ILM flap than ILM peeling (mean difference (MD) = − 0.16, 95% CI = − 0.23 to 0.09; P < 0.00001). However, there was no difference in visual outcomes between the two groups of different surgical treatments at relatively long-term follow-up over 6 months (MD = 0.01, 95% CI = − 0.12 to 0.15; P = 0.86). CONCLUSION: Vitrectomy with inverted ILM flap technique had a better anatomical outcome than ILM peeling. Flap technique also had a signifcant visual gain in the short term, but the limitations in visual recovery at a longer follow-up was found. BioMed Central 2020-01-08 /pmc/articles/PMC6950886/ /pubmed/31914954 http://dx.doi.org/10.1186/s12886-019-1271-2 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Shen, Yu Lin, Xiaoqin Zhang, Luyi Wu, Miaoqin Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title | Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title_full | Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title_fullStr | Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title_full_unstemmed | Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title_short | Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
title_sort | comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6950886/ https://www.ncbi.nlm.nih.gov/pubmed/31914954 http://dx.doi.org/10.1186/s12886-019-1271-2 |
work_keys_str_mv | AT shenyu comparativeefficacyevaluationofinvertedinternallimitingmembraneflaptechniqueandinternallimitingmembranepeelinginlargemacularholesasystematicreviewandmetaanalysis AT linxiaoqin comparativeefficacyevaluationofinvertedinternallimitingmembraneflaptechniqueandinternallimitingmembranepeelinginlargemacularholesasystematicreviewandmetaanalysis AT zhangluyi comparativeefficacyevaluationofinvertedinternallimitingmembraneflaptechniqueandinternallimitingmembranepeelinginlargemacularholesasystematicreviewandmetaanalysis AT wumiaoqin comparativeefficacyevaluationofinvertedinternallimitingmembraneflaptechniqueandinternallimitingmembranepeelinginlargemacularholesasystematicreviewandmetaanalysis |