Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine

A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine) (Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(M...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomes, Eliziana S., Leite, Fernando R.F., Ferraz, Bruno R.L., Mourão, Henrique A.J.L., Malagutti, Andréa R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951483/
https://www.ncbi.nlm.nih.gov/pubmed/31929944
http://dx.doi.org/10.1016/j.jpha.2019.04.001
_version_ 1783486281846620160
author Gomes, Eliziana S.
Leite, Fernando R.F.
Ferraz, Bruno R.L.
Mourão, Henrique A.J.L.
Malagutti, Andréa R.
author_facet Gomes, Eliziana S.
Leite, Fernando R.F.
Ferraz, Bruno R.L.
Mourão, Henrique A.J.L.
Malagutti, Andréa R.
author_sort Gomes, Eliziana S.
collection PubMed
description A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine) (Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at +0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH = 7.0). Different voltammetric scan rates (10–200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R(2) = 0.996) and from 5.66 μmol/L to 9.90 μmol/L (R(2) = 0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Co-poly(Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%–103% and 98.7%–102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols.
format Online
Article
Text
id pubmed-6951483
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-69514832020-01-10 Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine Gomes, Eliziana S. Leite, Fernando R.F. Ferraz, Bruno R.L. Mourão, Henrique A.J.L. Malagutti, Andréa R. J Pharm Anal Article A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine) (Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at +0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH = 7.0). Different voltammetric scan rates (10–200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R(2) = 0.996) and from 5.66 μmol/L to 9.90 μmol/L (R(2) = 0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Co-poly(Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%–103% and 98.7%–102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols. Xi'an Jiaotong University 2019-10 2019-04-05 /pmc/articles/PMC6951483/ /pubmed/31929944 http://dx.doi.org/10.1016/j.jpha.2019.04.001 Text en © 2019 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Gomes, Eliziana S.
Leite, Fernando R.F.
Ferraz, Bruno R.L.
Mourão, Henrique A.J.L.
Malagutti, Andréa R.
Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title_full Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title_fullStr Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title_full_unstemmed Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title_short Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
title_sort voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951483/
https://www.ncbi.nlm.nih.gov/pubmed/31929944
http://dx.doi.org/10.1016/j.jpha.2019.04.001
work_keys_str_mv AT gomeselizianas voltammetricsensorbasedoncobaltpolymethioninemodifiedglassycarbonelectrodefordeterminationofestriolhormoneinpharmaceuticalsandurine
AT leitefernandorf voltammetricsensorbasedoncobaltpolymethioninemodifiedglassycarbonelectrodefordeterminationofestriolhormoneinpharmaceuticalsandurine
AT ferrazbrunorl voltammetricsensorbasedoncobaltpolymethioninemodifiedglassycarbonelectrodefordeterminationofestriolhormoneinpharmaceuticalsandurine
AT mouraohenriqueajl voltammetricsensorbasedoncobaltpolymethioninemodifiedglassycarbonelectrodefordeterminationofestriolhormoneinpharmaceuticalsandurine
AT malaguttiandrear voltammetricsensorbasedoncobaltpolymethioninemodifiedglassycarbonelectrodefordeterminationofestriolhormoneinpharmaceuticalsandurine