Cargando…

Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports

BACKGROUND: Phrenic nerve (PN) injury is one of the recognized possible complications following epicardial ablation of ventricular tachycardia (VT). High-output pacing is a widely used maneuver to establish a relationship between the PN and the ablation catheter tip. An absence of PN capture is usua...

Descripción completa

Detalles Bibliográficos
Autores principales: Conti, Sergio, Bonomo, Vito, Taormina, Antonio, Giordano, Umberto, Sgarito, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6952720/
https://www.ncbi.nlm.nih.gov/pubmed/31984128
http://dx.doi.org/10.4330/wjc.v12.i1.55
_version_ 1783486485391998976
author Conti, Sergio
Bonomo, Vito
Taormina, Antonio
Giordano, Umberto
Sgarito, Giuseppe
author_facet Conti, Sergio
Bonomo, Vito
Taormina, Antonio
Giordano, Umberto
Sgarito, Giuseppe
author_sort Conti, Sergio
collection PubMed
description BACKGROUND: Phrenic nerve (PN) injury is one of the recognized possible complications following epicardial ablation of ventricular tachycardia (VT). High-output pacing is a widely used maneuver to establish a relationship between the PN and the ablation catheter tip. An absence of PN capture is usually considered an indication that it is safe to ablate, and that successful ablation may be performed at adjacent sites. However, PN capture may impact the procedural outcome. Only a few cases have been reported in the literature that avoid PN injury by using different techniques. CASE SUMMARY: Three patients with a previous history of myocarditis and one patient with ischemic cardiomyopathy underwent epicardial ablation for drug-refractory VT. Before the procedure, transthoracic echocardiogram, coronary angiogram, and cardiac magnetic resonance imaging were performed on all patients. Under general anesthesia, endo/epicardial three-dimensional anatomical and substrate maps of the left ventricle were accomplished. Before radiofrequency delivery, the course of the PN was identified by provoking diaphragmatic stimulation with high-output pacing from the distal electrode of the ablation catheter. In every case, a scar region with late potentials was mapped along the PN course. After obtaining another epicardial access, a second introducer sheath was placed, and a vascular balloon catheter was inserted into the epicardial space and inflated with saline solution to separate the PN from the epicardium. Once the absence of PN capture had been proven, radiofrequency was applied to aim for complete late potential elimination and avoid VT induction. CONCLUSION: PN injury can occur as one of the complications following epicardial VT ablation procedures, and may prevent successful ablation of these arrhythmias. PN displacement by using large balloon catheters into the epicardial space seems to be feasible and reproducible, avoid procedure-related morbidity, and improve ablation success when performed in selected centers and by experienced operators.
format Online
Article
Text
id pubmed-6952720
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-69527202020-01-26 Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports Conti, Sergio Bonomo, Vito Taormina, Antonio Giordano, Umberto Sgarito, Giuseppe World J Cardiol Case Report BACKGROUND: Phrenic nerve (PN) injury is one of the recognized possible complications following epicardial ablation of ventricular tachycardia (VT). High-output pacing is a widely used maneuver to establish a relationship between the PN and the ablation catheter tip. An absence of PN capture is usually considered an indication that it is safe to ablate, and that successful ablation may be performed at adjacent sites. However, PN capture may impact the procedural outcome. Only a few cases have been reported in the literature that avoid PN injury by using different techniques. CASE SUMMARY: Three patients with a previous history of myocarditis and one patient with ischemic cardiomyopathy underwent epicardial ablation for drug-refractory VT. Before the procedure, transthoracic echocardiogram, coronary angiogram, and cardiac magnetic resonance imaging were performed on all patients. Under general anesthesia, endo/epicardial three-dimensional anatomical and substrate maps of the left ventricle were accomplished. Before radiofrequency delivery, the course of the PN was identified by provoking diaphragmatic stimulation with high-output pacing from the distal electrode of the ablation catheter. In every case, a scar region with late potentials was mapped along the PN course. After obtaining another epicardial access, a second introducer sheath was placed, and a vascular balloon catheter was inserted into the epicardial space and inflated with saline solution to separate the PN from the epicardium. Once the absence of PN capture had been proven, radiofrequency was applied to aim for complete late potential elimination and avoid VT induction. CONCLUSION: PN injury can occur as one of the complications following epicardial VT ablation procedures, and may prevent successful ablation of these arrhythmias. PN displacement by using large balloon catheters into the epicardial space seems to be feasible and reproducible, avoid procedure-related morbidity, and improve ablation success when performed in selected centers and by experienced operators. Baishideng Publishing Group Inc 2020-01-26 2020-01-26 /pmc/articles/PMC6952720/ /pubmed/31984128 http://dx.doi.org/10.4330/wjc.v12.i1.55 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Case Report
Conti, Sergio
Bonomo, Vito
Taormina, Antonio
Giordano, Umberto
Sgarito, Giuseppe
Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title_full Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title_fullStr Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title_full_unstemmed Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title_short Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
title_sort phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: four case reports
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6952720/
https://www.ncbi.nlm.nih.gov/pubmed/31984128
http://dx.doi.org/10.4330/wjc.v12.i1.55
work_keys_str_mv AT contisergio phrenicnervedisplacementbyintrapericardialballooninflationduringepicardialablationofventriculartachycardiafourcasereports
AT bonomovito phrenicnervedisplacementbyintrapericardialballooninflationduringepicardialablationofventriculartachycardiafourcasereports
AT taorminaantonio phrenicnervedisplacementbyintrapericardialballooninflationduringepicardialablationofventriculartachycardiafourcasereports
AT giordanoumberto phrenicnervedisplacementbyintrapericardialballooninflationduringepicardialablationofventriculartachycardiafourcasereports
AT sgaritogiuseppe phrenicnervedisplacementbyintrapericardialballooninflationduringepicardialablationofventriculartachycardiafourcasereports