Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbe...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6953116/ https://www.ncbi.nlm.nih.gov/pubmed/31801238 http://dx.doi.org/10.3390/mi10120837 |
_version_ | 1783486577433903104 |
---|---|
author | Lai, Yu-Ting Tsai, Chia-Hsin Hsu, Ju-Chun Lu, Yen-Wen |
author_facet | Lai, Yu-Ting Tsai, Chia-Hsin Hsu, Ju-Chun Lu, Yen-Wen |
author_sort | Lai, Yu-Ting |
collection | PubMed |
description | Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbent assay (ELISA) on a paper-based device. The mechanism employs a controllable time-delay valve, which has surfactants to dissolve the hydrophobic barriers, in a fluid pathway. The valves can regulate the liquid and sequentially deliver the sample flow for automating ELISA procedures in microchannels. Competitive ELISA is achieved in a single step once the sample, or small molecule pesticide (e.g., Imidacloprid), is applied onto the paper-based device with a comparable sensitivity to plate-based competitive ELISA. The results further demonstrate the appositeness of using paper-based devices with the valve designs for on-the-go ELISA detection in agriculture and biomedical applications. |
format | Online Article Text |
id | pubmed-6953116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69531162020-01-23 Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA Lai, Yu-Ting Tsai, Chia-Hsin Hsu, Ju-Chun Lu, Yen-Wen Micromachines (Basel) Article Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbent assay (ELISA) on a paper-based device. The mechanism employs a controllable time-delay valve, which has surfactants to dissolve the hydrophobic barriers, in a fluid pathway. The valves can regulate the liquid and sequentially deliver the sample flow for automating ELISA procedures in microchannels. Competitive ELISA is achieved in a single step once the sample, or small molecule pesticide (e.g., Imidacloprid), is applied onto the paper-based device with a comparable sensitivity to plate-based competitive ELISA. The results further demonstrate the appositeness of using paper-based devices with the valve designs for on-the-go ELISA detection in agriculture and biomedical applications. MDPI 2019-11-30 /pmc/articles/PMC6953116/ /pubmed/31801238 http://dx.doi.org/10.3390/mi10120837 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lai, Yu-Ting Tsai, Chia-Hsin Hsu, Ju-Chun Lu, Yen-Wen Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title | Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title_full | Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title_fullStr | Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title_full_unstemmed | Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title_short | Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA |
title_sort | microfluidic time-delay valve mechanism on paper-based devices for automated competitive elisa |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6953116/ https://www.ncbi.nlm.nih.gov/pubmed/31801238 http://dx.doi.org/10.3390/mi10120837 |
work_keys_str_mv | AT laiyuting microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa AT tsaichiahsin microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa AT hsujuchun microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa AT luyenwen microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa |