Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA

Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbe...

Descripción completa

Detalles Bibliográficos
Autores principales: Lai, Yu-Ting, Tsai, Chia-Hsin, Hsu, Ju-Chun, Lu, Yen-Wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6953116/
https://www.ncbi.nlm.nih.gov/pubmed/31801238
http://dx.doi.org/10.3390/mi10120837
_version_ 1783486577433903104
author Lai, Yu-Ting
Tsai, Chia-Hsin
Hsu, Ju-Chun
Lu, Yen-Wen
author_facet Lai, Yu-Ting
Tsai, Chia-Hsin
Hsu, Ju-Chun
Lu, Yen-Wen
author_sort Lai, Yu-Ting
collection PubMed
description Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbent assay (ELISA) on a paper-based device. The mechanism employs a controllable time-delay valve, which has surfactants to dissolve the hydrophobic barriers, in a fluid pathway. The valves can regulate the liquid and sequentially deliver the sample flow for automating ELISA procedures in microchannels. Competitive ELISA is achieved in a single step once the sample, or small molecule pesticide (e.g., Imidacloprid), is applied onto the paper-based device with a comparable sensitivity to plate-based competitive ELISA. The results further demonstrate the appositeness of using paper-based devices with the valve designs for on-the-go ELISA detection in agriculture and biomedical applications.
format Online
Article
Text
id pubmed-6953116
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69531162020-01-23 Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA Lai, Yu-Ting Tsai, Chia-Hsin Hsu, Ju-Chun Lu, Yen-Wen Micromachines (Basel) Article Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbent assay (ELISA) on a paper-based device. The mechanism employs a controllable time-delay valve, which has surfactants to dissolve the hydrophobic barriers, in a fluid pathway. The valves can regulate the liquid and sequentially deliver the sample flow for automating ELISA procedures in microchannels. Competitive ELISA is achieved in a single step once the sample, or small molecule pesticide (e.g., Imidacloprid), is applied onto the paper-based device with a comparable sensitivity to plate-based competitive ELISA. The results further demonstrate the appositeness of using paper-based devices with the valve designs for on-the-go ELISA detection in agriculture and biomedical applications. MDPI 2019-11-30 /pmc/articles/PMC6953116/ /pubmed/31801238 http://dx.doi.org/10.3390/mi10120837 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lai, Yu-Ting
Tsai, Chia-Hsin
Hsu, Ju-Chun
Lu, Yen-Wen
Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title_full Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title_fullStr Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title_full_unstemmed Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title_short Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
title_sort microfluidic time-delay valve mechanism on paper-based devices for automated competitive elisa
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6953116/
https://www.ncbi.nlm.nih.gov/pubmed/31801238
http://dx.doi.org/10.3390/mi10120837
work_keys_str_mv AT laiyuting microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa
AT tsaichiahsin microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa
AT hsujuchun microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa
AT luyenwen microfluidictimedelayvalvemechanismonpaperbaseddevicesforautomatedcompetitiveelisa