Cargando…

Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release

BAKGROUND: The objective of this study is to investigate the prognostic values of median nerve strain and applied pressure measurement for the assessment of clinical recovery after carpal tunnel release. METHODS: Forty-five wrists, from 45 idiopathic carpal tunnel syndrome patients who treated with...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshii, Yuichi, Tung, Wen-lin, Yuine, Hiroshi, Ishii, Tomoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955092/
https://www.ncbi.nlm.nih.gov/pubmed/31926552
http://dx.doi.org/10.1186/s12891-019-3033-y
_version_ 1783486889658941440
author Yoshii, Yuichi
Tung, Wen-lin
Yuine, Hiroshi
Ishii, Tomoo
author_facet Yoshii, Yuichi
Tung, Wen-lin
Yuine, Hiroshi
Ishii, Tomoo
author_sort Yoshii, Yuichi
collection PubMed
description BAKGROUND: The objective of this study is to investigate the prognostic values of median nerve strain and applied pressure measurement for the assessment of clinical recovery after carpal tunnel release. METHODS: Forty-five wrists, from 45 idiopathic carpal tunnel syndrome patients who treated with open carpal tunnel release, were evaluated by ultrasound. Median nerve strain, pressure applied to the skin, and ratio of pressure-strain were measured at the proximal part of the carpal tunnel. In addition, distal latencies in the motor and sensory nerve conductions studies and cross-sectional area of median nerve were measured. The parameters were compared before and after the open carpal tunnel release. According to patient recovery, the receiver operating characteristic curves were generated to evaluate the prognostic values of the parameters. The areas under the receiver operating characteristic curves were compared among parameters. RESULTS: There was a significant increase in the median nerve strain, and significant decreases in the pressure applied to the skin and ratio of pressure-strain after carpal tunnel release (P < 0.01). There were significant decreases in the distal latencies and the cross-sectional area after carpal tunnel release (P < 0.01). The areas under the curves were 0.689, 0.773, 0.811, 0.668, 0.637, and 0.562 for the pressure, strain, pressure-strain ratio, motor latency, sensory latency, and area, respectively. CONCLUSIONS: The results suggest that elasticity of the median nerve and pressure around the nerve recover quickly after carpal tunnel release. Pressure-strain ratio was the most reliable parameter to reflect clinical recovery. The measurement of strain and applied pressure can be useful indicators to evaluate effectiveness of the carpal tunnel release. TRIAL REGISTRATION: Registered as NCT04027998 at ClinicalTrials.gov. Retrospectively registered on July 22, 2019.
format Online
Article
Text
id pubmed-6955092
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69550922020-01-14 Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release Yoshii, Yuichi Tung, Wen-lin Yuine, Hiroshi Ishii, Tomoo BMC Musculoskelet Disord Research Article BAKGROUND: The objective of this study is to investigate the prognostic values of median nerve strain and applied pressure measurement for the assessment of clinical recovery after carpal tunnel release. METHODS: Forty-five wrists, from 45 idiopathic carpal tunnel syndrome patients who treated with open carpal tunnel release, were evaluated by ultrasound. Median nerve strain, pressure applied to the skin, and ratio of pressure-strain were measured at the proximal part of the carpal tunnel. In addition, distal latencies in the motor and sensory nerve conductions studies and cross-sectional area of median nerve were measured. The parameters were compared before and after the open carpal tunnel release. According to patient recovery, the receiver operating characteristic curves were generated to evaluate the prognostic values of the parameters. The areas under the receiver operating characteristic curves were compared among parameters. RESULTS: There was a significant increase in the median nerve strain, and significant decreases in the pressure applied to the skin and ratio of pressure-strain after carpal tunnel release (P < 0.01). There were significant decreases in the distal latencies and the cross-sectional area after carpal tunnel release (P < 0.01). The areas under the curves were 0.689, 0.773, 0.811, 0.668, 0.637, and 0.562 for the pressure, strain, pressure-strain ratio, motor latency, sensory latency, and area, respectively. CONCLUSIONS: The results suggest that elasticity of the median nerve and pressure around the nerve recover quickly after carpal tunnel release. Pressure-strain ratio was the most reliable parameter to reflect clinical recovery. The measurement of strain and applied pressure can be useful indicators to evaluate effectiveness of the carpal tunnel release. TRIAL REGISTRATION: Registered as NCT04027998 at ClinicalTrials.gov. Retrospectively registered on July 22, 2019. BioMed Central 2020-01-11 /pmc/articles/PMC6955092/ /pubmed/31926552 http://dx.doi.org/10.1186/s12891-019-3033-y Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Yoshii, Yuichi
Tung, Wen-lin
Yuine, Hiroshi
Ishii, Tomoo
Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title_full Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title_fullStr Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title_full_unstemmed Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title_short Postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
title_sort postoperative diagnostic potentials of median nerve strain and applied pressure measurement after carpal tunnel release
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955092/
https://www.ncbi.nlm.nih.gov/pubmed/31926552
http://dx.doi.org/10.1186/s12891-019-3033-y
work_keys_str_mv AT yoshiiyuichi postoperativediagnosticpotentialsofmediannervestrainandappliedpressuremeasurementaftercarpaltunnelrelease
AT tungwenlin postoperativediagnosticpotentialsofmediannervestrainandappliedpressuremeasurementaftercarpaltunnelrelease
AT yuinehiroshi postoperativediagnosticpotentialsofmediannervestrainandappliedpressuremeasurementaftercarpaltunnelrelease
AT ishiitomoo postoperativediagnosticpotentialsofmediannervestrainandappliedpressuremeasurementaftercarpaltunnelrelease