Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955184/ https://www.ncbi.nlm.nih.gov/pubmed/31917914 http://dx.doi.org/10.5056/jnm19082 |
_version_ | 1783486905681182720 |
---|---|
author | Srinivas, Melpakkam Jain, Mayank Bawane, Piyush Jayanthi, Venkataraman |
author_facet | Srinivas, Melpakkam Jain, Mayank Bawane, Piyush Jayanthi, Venkataraman |
author_sort | Srinivas, Melpakkam |
collection | PubMed |
description | BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for a 16-channel water perfused system (Dentsleeve HREM catheter, Advanced Manometry Systems, Melbourne, Australia) widely used in India and other countries with limited access to solid-state equipment. The results are compared with published CC metrics in supine position done using the same system and volunteers. METHODS: HREM tracings of ten 5 mL water swallows in sitting posture were acquired in healthy volunteers and normative values for CC version 3.0 metrics calculated. Individual swallows were paired with previously reported supine swallows for postural variations (Wilcoxon sign rank test) and concordance of CC diagnoses (Pearson coefficient). RESULTS: Analysis of 530 sitting posture water swallows (53 subjects) and comparison with their supine data revealed significantly higher integrated relaxation pressure (IRP; median 6.7 mmHg vs 6.1 mmHg) but lower distal latency (DL; mean 6.3 seconds vs 6.8 seconds) and distal contractile integral (DCI; mean 1224 mmHg sec cm vs 1456 mmHg sec cm). Sitting posture normal was defined as: IRP < 13.9, DL > 4.5, and DCI = 115–4500 (absent contractility: DCI < 30). CC diagnoses concordance using posture-specific cut-offs was moderate (k = 0.47). CONCLUSIONS: This paper provides normative values for the Advanced Manometry Systems 16-channel water perfused system in the physiological seated position for CC metrics. Our findings of higher IRP and lower DCI in sitting posture than previously reported supine CC cut-offs, confirm the need to use posture-specific cut-offs for reporting HREM tracings. |
format | Online Article Text |
id | pubmed-6955184 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-69551842020-01-22 Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers Srinivas, Melpakkam Jain, Mayank Bawane, Piyush Jayanthi, Venkataraman J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for a 16-channel water perfused system (Dentsleeve HREM catheter, Advanced Manometry Systems, Melbourne, Australia) widely used in India and other countries with limited access to solid-state equipment. The results are compared with published CC metrics in supine position done using the same system and volunteers. METHODS: HREM tracings of ten 5 mL water swallows in sitting posture were acquired in healthy volunteers and normative values for CC version 3.0 metrics calculated. Individual swallows were paired with previously reported supine swallows for postural variations (Wilcoxon sign rank test) and concordance of CC diagnoses (Pearson coefficient). RESULTS: Analysis of 530 sitting posture water swallows (53 subjects) and comparison with their supine data revealed significantly higher integrated relaxation pressure (IRP; median 6.7 mmHg vs 6.1 mmHg) but lower distal latency (DL; mean 6.3 seconds vs 6.8 seconds) and distal contractile integral (DCI; mean 1224 mmHg sec cm vs 1456 mmHg sec cm). Sitting posture normal was defined as: IRP < 13.9, DL > 4.5, and DCI = 115–4500 (absent contractility: DCI < 30). CC diagnoses concordance using posture-specific cut-offs was moderate (k = 0.47). CONCLUSIONS: This paper provides normative values for the Advanced Manometry Systems 16-channel water perfused system in the physiological seated position for CC metrics. Our findings of higher IRP and lower DCI in sitting posture than previously reported supine CC cut-offs, confirm the need to use posture-specific cut-offs for reporting HREM tracings. Korean Society of Neurogastroenterology and Motility 2020-01 2020-01-30 /pmc/articles/PMC6955184/ /pubmed/31917914 http://dx.doi.org/10.5056/jnm19082 Text en © 2020 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Srinivas, Melpakkam Jain, Mayank Bawane, Piyush Jayanthi, Venkataraman Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title | Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title_full | Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title_fullStr | Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title_full_unstemmed | Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title_short | Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers |
title_sort | normative values for esophageal motility assessed in the physiological seated position for 16-channel water perfused high-resolution esophageal manometry system and postural variations in healthy volunteers |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955184/ https://www.ncbi.nlm.nih.gov/pubmed/31917914 http://dx.doi.org/10.5056/jnm19082 |
work_keys_str_mv | AT srinivasmelpakkam normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers AT jainmayank normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers AT bawanepiyush normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers AT jayanthivenkataraman normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers |