Cargando…

Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers

BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for...

Descripción completa

Detalles Bibliográficos
Autores principales: Srinivas, Melpakkam, Jain, Mayank, Bawane, Piyush, Jayanthi, Venkataraman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Neurogastroenterology and Motility 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955184/
https://www.ncbi.nlm.nih.gov/pubmed/31917914
http://dx.doi.org/10.5056/jnm19082
_version_ 1783486905681182720
author Srinivas, Melpakkam
Jain, Mayank
Bawane, Piyush
Jayanthi, Venkataraman
author_facet Srinivas, Melpakkam
Jain, Mayank
Bawane, Piyush
Jayanthi, Venkataraman
author_sort Srinivas, Melpakkam
collection PubMed
description BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for a 16-channel water perfused system (Dentsleeve HREM catheter, Advanced Manometry Systems, Melbourne, Australia) widely used in India and other countries with limited access to solid-state equipment. The results are compared with published CC metrics in supine position done using the same system and volunteers. METHODS: HREM tracings of ten 5 mL water swallows in sitting posture were acquired in healthy volunteers and normative values for CC version 3.0 metrics calculated. Individual swallows were paired with previously reported supine swallows for postural variations (Wilcoxon sign rank test) and concordance of CC diagnoses (Pearson coefficient). RESULTS: Analysis of 530 sitting posture water swallows (53 subjects) and comparison with their supine data revealed significantly higher integrated relaxation pressure (IRP; median 6.7 mmHg vs 6.1 mmHg) but lower distal latency (DL; mean 6.3 seconds vs 6.8 seconds) and distal contractile integral (DCI; mean 1224 mmHg sec cm vs 1456 mmHg sec cm). Sitting posture normal was defined as: IRP < 13.9, DL > 4.5, and DCI = 115–4500 (absent contractility: DCI < 30). CC diagnoses concordance using posture-specific cut-offs was moderate (k = 0.47). CONCLUSIONS: This paper provides normative values for the Advanced Manometry Systems 16-channel water perfused system in the physiological seated position for CC metrics. Our findings of higher IRP and lower DCI in sitting posture than previously reported supine CC cut-offs, confirm the need to use posture-specific cut-offs for reporting HREM tracings.
format Online
Article
Text
id pubmed-6955184
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Neurogastroenterology and Motility
record_format MEDLINE/PubMed
spelling pubmed-69551842020-01-22 Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers Srinivas, Melpakkam Jain, Mayank Bawane, Piyush Jayanthi, Venkataraman J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Consensus guidelines for performance and analysis of high-resolution esophageal manometry (HREM) recommend use of equipment, population and posture specific normative values. To provide normative values for Chicago classification (CC) metrics in the physiological seated position for a 16-channel water perfused system (Dentsleeve HREM catheter, Advanced Manometry Systems, Melbourne, Australia) widely used in India and other countries with limited access to solid-state equipment. The results are compared with published CC metrics in supine position done using the same system and volunteers. METHODS: HREM tracings of ten 5 mL water swallows in sitting posture were acquired in healthy volunteers and normative values for CC version 3.0 metrics calculated. Individual swallows were paired with previously reported supine swallows for postural variations (Wilcoxon sign rank test) and concordance of CC diagnoses (Pearson coefficient). RESULTS: Analysis of 530 sitting posture water swallows (53 subjects) and comparison with their supine data revealed significantly higher integrated relaxation pressure (IRP; median 6.7 mmHg vs 6.1 mmHg) but lower distal latency (DL; mean 6.3 seconds vs 6.8 seconds) and distal contractile integral (DCI; mean 1224 mmHg sec cm vs 1456 mmHg sec cm). Sitting posture normal was defined as: IRP < 13.9, DL > 4.5, and DCI = 115–4500 (absent contractility: DCI < 30). CC diagnoses concordance using posture-specific cut-offs was moderate (k = 0.47). CONCLUSIONS: This paper provides normative values for the Advanced Manometry Systems 16-channel water perfused system in the physiological seated position for CC metrics. Our findings of higher IRP and lower DCI in sitting posture than previously reported supine CC cut-offs, confirm the need to use posture-specific cut-offs for reporting HREM tracings. Korean Society of Neurogastroenterology and Motility 2020-01 2020-01-30 /pmc/articles/PMC6955184/ /pubmed/31917914 http://dx.doi.org/10.5056/jnm19082 Text en © 2020 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Srinivas, Melpakkam
Jain, Mayank
Bawane, Piyush
Jayanthi, Venkataraman
Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title_full Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title_fullStr Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title_full_unstemmed Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title_short Normative Values for Esophageal Motility Assessed in the Physiological Seated Position for 16-Channel Water Perfused High-resolution Esophageal Manometry System and Postural Variations in Healthy Volunteers
title_sort normative values for esophageal motility assessed in the physiological seated position for 16-channel water perfused high-resolution esophageal manometry system and postural variations in healthy volunteers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6955184/
https://www.ncbi.nlm.nih.gov/pubmed/31917914
http://dx.doi.org/10.5056/jnm19082
work_keys_str_mv AT srinivasmelpakkam normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers
AT jainmayank normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers
AT bawanepiyush normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers
AT jayanthivenkataraman normativevaluesforesophagealmotilityassessedinthephysiologicalseatedpositionfor16channelwaterperfusedhighresolutionesophagealmanometrysystemandposturalvariationsinhealthyvolunteers