Cargando…
Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin
Blood–saliva contamination negatively affects the bonding potential of adhesive agents. The study aimed to assess the effect of various cleaning protocols on micro-shear bond strength (μSBS) between blood–saliva-contaminated post-etched dentin and composite resin in total-etch and self-etch adhesive...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6956069/ https://www.ncbi.nlm.nih.gov/pubmed/31683858 http://dx.doi.org/10.3390/healthcare7040128 |
_version_ | 1783487075386916864 |
---|---|
author | Haralur, Satheesh B. Alharthi, Salem Mohammed Abohasel, Saeed Aied alqahtani, Khalid Mohammed |
author_facet | Haralur, Satheesh B. Alharthi, Salem Mohammed Abohasel, Saeed Aied alqahtani, Khalid Mohammed |
author_sort | Haralur, Satheesh B. |
collection | PubMed |
description | Blood–saliva contamination negatively affects the bonding potential of adhesive agents. The study aimed to assess the effect of various cleaning protocols on micro-shear bond strength (μSBS) between blood–saliva-contaminated post-etched dentin and composite resin in total-etch and self-etch adhesives. The cleaning methods tested were water rinsing, 37.5% phosphoric acid (H3PO4) re-etching, 6% sodium hypochlorite (NaoCl), 2% chlorhexidine gluconate (CXG), isopropyl alcohol (IPA), and pumice. Nono-hybrid composite cylinders with a 3-mm diameter and 2-mm height were directly cured over the dentin substrate, stored for 24 h, and subjected to 12,000 thermocycles. The shear force was exerted with a 200-μm knife-edged chisel-shaped head from a universal testing machine. The type of failure was assessed with stereomicroscope magnified images. The obtained data were evaluated by Kruskal–Wallis and Mann–Whitney U post-hoc tests. Water-rinsed contaminated dentin surfaces showed substantially reduced μSBS in the total etch from 25.93 to 20.29 Mpa and the corresponding values for the one-step self-etch adhesive were 10.10 to 8.8. Re-etching with 37.5% H3Po4 resulted in a recovery of bonding potential in both total-etch (24.58 Mpa) and self-etch adhesive (9.23 Mpa). Alternately, NaoCl and pumice cleaning showed promising results for the total-etch (23.51 Mpa) and self-etch (7.79 Mpa). |
format | Online Article Text |
id | pubmed-6956069 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69560692020-01-23 Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin Haralur, Satheesh B. Alharthi, Salem Mohammed Abohasel, Saeed Aied alqahtani, Khalid Mohammed Healthcare (Basel) Article Blood–saliva contamination negatively affects the bonding potential of adhesive agents. The study aimed to assess the effect of various cleaning protocols on micro-shear bond strength (μSBS) between blood–saliva-contaminated post-etched dentin and composite resin in total-etch and self-etch adhesives. The cleaning methods tested were water rinsing, 37.5% phosphoric acid (H3PO4) re-etching, 6% sodium hypochlorite (NaoCl), 2% chlorhexidine gluconate (CXG), isopropyl alcohol (IPA), and pumice. Nono-hybrid composite cylinders with a 3-mm diameter and 2-mm height were directly cured over the dentin substrate, stored for 24 h, and subjected to 12,000 thermocycles. The shear force was exerted with a 200-μm knife-edged chisel-shaped head from a universal testing machine. The type of failure was assessed with stereomicroscope magnified images. The obtained data were evaluated by Kruskal–Wallis and Mann–Whitney U post-hoc tests. Water-rinsed contaminated dentin surfaces showed substantially reduced μSBS in the total etch from 25.93 to 20.29 Mpa and the corresponding values for the one-step self-etch adhesive were 10.10 to 8.8. Re-etching with 37.5% H3Po4 resulted in a recovery of bonding potential in both total-etch (24.58 Mpa) and self-etch adhesive (9.23 Mpa). Alternately, NaoCl and pumice cleaning showed promising results for the total-etch (23.51 Mpa) and self-etch (7.79 Mpa). MDPI 2019-11-01 /pmc/articles/PMC6956069/ /pubmed/31683858 http://dx.doi.org/10.3390/healthcare7040128 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Haralur, Satheesh B. Alharthi, Salem Mohammed Abohasel, Saeed Aied alqahtani, Khalid Mohammed Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title | Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title_full | Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title_fullStr | Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title_full_unstemmed | Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title_short | Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood–Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin |
title_sort | effect of decontamination treatments on micro-shear bond strength between blood–saliva-contaminated post-etched dentin substrate and composite resin |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6956069/ https://www.ncbi.nlm.nih.gov/pubmed/31683858 http://dx.doi.org/10.3390/healthcare7040128 |
work_keys_str_mv | AT haralursatheeshb effectofdecontaminationtreatmentsonmicroshearbondstrengthbetweenbloodsalivacontaminatedpostetcheddentinsubstrateandcompositeresin AT alharthisalemmohammed effectofdecontaminationtreatmentsonmicroshearbondstrengthbetweenbloodsalivacontaminatedpostetcheddentinsubstrateandcompositeresin AT abohaselsaeedaied effectofdecontaminationtreatmentsonmicroshearbondstrengthbetweenbloodsalivacontaminatedpostetcheddentinsubstrateandcompositeresin AT alqahtanikhalidmohammed effectofdecontaminationtreatmentsonmicroshearbondstrengthbetweenbloodsalivacontaminatedpostetcheddentinsubstrateandcompositeresin |