Cargando…
Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department
BACKGROUND: Rapid magnetic resonance imaging (MRI) protocols may be effective in the emergency department (ED) to evaluate nontraumatic neurologic complaints. We evaluate neuroimaging (rapid MRI [rMRI]), head computerized tomography [HCT], and full MRI) use following widespread implementation of rMR...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6956479/ https://www.ncbi.nlm.nih.gov/pubmed/31931764 http://dx.doi.org/10.1186/s12887-020-1919-3 |
_version_ | 1783487159430283264 |
---|---|
author | Ramgopal, Sriram Karim, Sabrina A. Subramanian, Subramanian Furtado, Andre D. Marin, Jennifer R. |
author_facet | Ramgopal, Sriram Karim, Sabrina A. Subramanian, Subramanian Furtado, Andre D. Marin, Jennifer R. |
author_sort | Ramgopal, Sriram |
collection | PubMed |
description | BACKGROUND: Rapid magnetic resonance imaging (MRI) protocols may be effective in the emergency department (ED) to evaluate nontraumatic neurologic complaints. We evaluate neuroimaging (rapid MRI [rMRI]), head computerized tomography [HCT], and full MRI) use following widespread implementation of rMRI protocols in a pediatric emergency department (ED). METHODS: We conducted a retrospective study in a tertiary care pediatric ED of encounters with neuroimaging during two 9-month periods: one prior to (control period) and one after generalized availability of 4 rMRI protocols (rMRI period). The primary outcome was differences in neuroimaging rates between the two periods. Secondary outcomes included ED process measures, unsuccessful imaging, and undetected pathology, with full MRI within 14 days as the reference standard. RESULTS: There were 1052 encounters with neuroimaging during the control and 1308 during the rMRI periods. Differences in neuroimaging between periods were 27.7% for rMRI (95% CI, 24.4, 31.0), − 21.5% for HCT (95% CI, − 25.5, − 17.5), and − 6.2% for full MRI (95% CI, − 9.3, − 3.1%.) Time to imaging (182 [IQR 138–255] versus 86 [IQR 52–137] minutes) as well as ED length of stay (396 [IQR 304–484] versus 257 [IQR 196–334] minutes) was longer for rMRI versus HCT (p < 0.01). Between the control and rMRI periods, there were differences in types of neuroimaging performed for patients with altered mental status, headache, seizure, shunt dysfunction, stroke, syncope, trauma, vomiting, infection, and other neurologic complaints (p < 0.05). rMRI studies were unsuccessful in 3.6% of studies versus 0.0% of HCTs (p < 0.01). The 22 unsuccessful rMRI studies were unsuccessful due to artifacts from dental hardware (n = 2) and patient motion (n = 20). None of the rMRI studies with full MRI follow-up imaging had undetected pathology; the false negative rate for the HCT exams was as high as 25%. CONCLUSIONS: After routine ED use of 4 rMRI protocols, there was a more than 20% decrease in HCT use without missed diagnoses. Time to neuroimaging and length of stay were longer for rMRI than HCT, with higher rates of unsuccessful imaging. Despite these limitations, rMRI may be an alternative to HCT for nontraumatic complaints in the ED. |
format | Online Article Text |
id | pubmed-6956479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-69564792020-01-17 Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department Ramgopal, Sriram Karim, Sabrina A. Subramanian, Subramanian Furtado, Andre D. Marin, Jennifer R. BMC Pediatr Research Article BACKGROUND: Rapid magnetic resonance imaging (MRI) protocols may be effective in the emergency department (ED) to evaluate nontraumatic neurologic complaints. We evaluate neuroimaging (rapid MRI [rMRI]), head computerized tomography [HCT], and full MRI) use following widespread implementation of rMRI protocols in a pediatric emergency department (ED). METHODS: We conducted a retrospective study in a tertiary care pediatric ED of encounters with neuroimaging during two 9-month periods: one prior to (control period) and one after generalized availability of 4 rMRI protocols (rMRI period). The primary outcome was differences in neuroimaging rates between the two periods. Secondary outcomes included ED process measures, unsuccessful imaging, and undetected pathology, with full MRI within 14 days as the reference standard. RESULTS: There were 1052 encounters with neuroimaging during the control and 1308 during the rMRI periods. Differences in neuroimaging between periods were 27.7% for rMRI (95% CI, 24.4, 31.0), − 21.5% for HCT (95% CI, − 25.5, − 17.5), and − 6.2% for full MRI (95% CI, − 9.3, − 3.1%.) Time to imaging (182 [IQR 138–255] versus 86 [IQR 52–137] minutes) as well as ED length of stay (396 [IQR 304–484] versus 257 [IQR 196–334] minutes) was longer for rMRI versus HCT (p < 0.01). Between the control and rMRI periods, there were differences in types of neuroimaging performed for patients with altered mental status, headache, seizure, shunt dysfunction, stroke, syncope, trauma, vomiting, infection, and other neurologic complaints (p < 0.05). rMRI studies were unsuccessful in 3.6% of studies versus 0.0% of HCTs (p < 0.01). The 22 unsuccessful rMRI studies were unsuccessful due to artifacts from dental hardware (n = 2) and patient motion (n = 20). None of the rMRI studies with full MRI follow-up imaging had undetected pathology; the false negative rate for the HCT exams was as high as 25%. CONCLUSIONS: After routine ED use of 4 rMRI protocols, there was a more than 20% decrease in HCT use without missed diagnoses. Time to neuroimaging and length of stay were longer for rMRI than HCT, with higher rates of unsuccessful imaging. Despite these limitations, rMRI may be an alternative to HCT for nontraumatic complaints in the ED. BioMed Central 2020-01-13 /pmc/articles/PMC6956479/ /pubmed/31931764 http://dx.doi.org/10.1186/s12887-020-1919-3 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Ramgopal, Sriram Karim, Sabrina A. Subramanian, Subramanian Furtado, Andre D. Marin, Jennifer R. Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title | Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title_full | Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title_fullStr | Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title_full_unstemmed | Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title_short | Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department |
title_sort | rapid brain mri protocols reduce head computerized tomography use in the pediatric emergency department |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6956479/ https://www.ncbi.nlm.nih.gov/pubmed/31931764 http://dx.doi.org/10.1186/s12887-020-1919-3 |
work_keys_str_mv | AT ramgopalsriram rapidbrainmriprotocolsreduceheadcomputerizedtomographyuseinthepediatricemergencydepartment AT karimsabrinaa rapidbrainmriprotocolsreduceheadcomputerizedtomographyuseinthepediatricemergencydepartment AT subramaniansubramanian rapidbrainmriprotocolsreduceheadcomputerizedtomographyuseinthepediatricemergencydepartment AT furtadoandred rapidbrainmriprotocolsreduceheadcomputerizedtomographyuseinthepediatricemergencydepartment AT marinjenniferr rapidbrainmriprotocolsreduceheadcomputerizedtomographyuseinthepediatricemergencydepartment |