Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy

Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image...

Descripción completa

Detalles Bibliográficos
Autores principales: Redler, Gage, Stevens, Tynan, Cammin, Jochen, Malin, Martha, Green, Olga, Mutic, Sasa, Pitroda, Sean, Aydogan, Bulent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957030/
https://www.ncbi.nlm.nih.gov/pubmed/31938646
http://dx.doi.org/10.7759/cureus.6364
_version_ 1783487250163564544
author Redler, Gage
Stevens, Tynan
Cammin, Jochen
Malin, Martha
Green, Olga
Mutic, Sasa
Pitroda, Sean
Aydogan, Bulent
author_facet Redler, Gage
Stevens, Tynan
Cammin, Jochen
Malin, Martha
Green, Olga
Mutic, Sasa
Pitroda, Sean
Aydogan, Bulent
author_sort Redler, Gage
collection PubMed
description Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (D(max): 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord D(max): 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) D(max): 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.
format Online
Article
Text
id pubmed-6957030
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-69570302020-01-14 Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy Redler, Gage Stevens, Tynan Cammin, Jochen Malin, Martha Green, Olga Mutic, Sasa Pitroda, Sean Aydogan, Bulent Cureus Radiation Oncology Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (D(max): 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord D(max): 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) D(max): 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy. Cureus 2019-12-12 /pmc/articles/PMC6957030/ /pubmed/31938646 http://dx.doi.org/10.7759/cureus.6364 Text en Copyright © 2019, Redler et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Radiation Oncology
Redler, Gage
Stevens, Tynan
Cammin, Jochen
Malin, Martha
Green, Olga
Mutic, Sasa
Pitroda, Sean
Aydogan, Bulent
Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title_full Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title_fullStr Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title_full_unstemmed Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title_short Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
title_sort dosimetric feasibility of utilizing the viewray magnetic resonance guided linac system for image-guided spine stereotactic body radiation therapy
topic Radiation Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957030/
https://www.ncbi.nlm.nih.gov/pubmed/31938646
http://dx.doi.org/10.7759/cureus.6364
work_keys_str_mv AT redlergage dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT stevenstynan dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT camminjochen dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT malinmartha dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT greenolga dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT muticsasa dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT pitrodasean dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy
AT aydoganbulent dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy