Cargando…
Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957030/ https://www.ncbi.nlm.nih.gov/pubmed/31938646 http://dx.doi.org/10.7759/cureus.6364 |
_version_ | 1783487250163564544 |
---|---|
author | Redler, Gage Stevens, Tynan Cammin, Jochen Malin, Martha Green, Olga Mutic, Sasa Pitroda, Sean Aydogan, Bulent |
author_facet | Redler, Gage Stevens, Tynan Cammin, Jochen Malin, Martha Green, Olga Mutic, Sasa Pitroda, Sean Aydogan, Bulent |
author_sort | Redler, Gage |
collection | PubMed |
description | Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (D(max): 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord D(max): 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) D(max): 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy. |
format | Online Article Text |
id | pubmed-6957030 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-69570302020-01-14 Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy Redler, Gage Stevens, Tynan Cammin, Jochen Malin, Martha Green, Olga Mutic, Sasa Pitroda, Sean Aydogan, Bulent Cureus Radiation Oncology Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (D(max): 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord D(max): 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) D(max): 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy. Cureus 2019-12-12 /pmc/articles/PMC6957030/ /pubmed/31938646 http://dx.doi.org/10.7759/cureus.6364 Text en Copyright © 2019, Redler et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Radiation Oncology Redler, Gage Stevens, Tynan Cammin, Jochen Malin, Martha Green, Olga Mutic, Sasa Pitroda, Sean Aydogan, Bulent Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title | Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title_full | Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title_fullStr | Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title_full_unstemmed | Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title_short | Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy |
title_sort | dosimetric feasibility of utilizing the viewray magnetic resonance guided linac system for image-guided spine stereotactic body radiation therapy |
topic | Radiation Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957030/ https://www.ncbi.nlm.nih.gov/pubmed/31938646 http://dx.doi.org/10.7759/cureus.6364 |
work_keys_str_mv | AT redlergage dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT stevenstynan dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT camminjochen dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT malinmartha dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT greenolga dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT muticsasa dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT pitrodasean dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy AT aydoganbulent dosimetricfeasibilityofutilizingtheviewraymagneticresonanceguidedlinacsystemforimageguidedspinestereotacticbodyradiationtherapy |