Cargando…
Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms
OBJECTIVE: We examined the accuracy of data from an affordable personal monitor (Fitbit Flex) compared with that of data from a research‐grade accelerometer worn simultaneously for 7 days; high accuracy would support substitution with this less‐expensive personal activity monitor in future community...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957919/ https://www.ncbi.nlm.nih.gov/pubmed/31943970 http://dx.doi.org/10.1002/acr2.11099 |
_version_ | 1783487380560281600 |
---|---|
author | Semanik, Pamela Lee, Jungwha Pellegrini, Christine A. Song, Jing Dunlop, Dorothy D. Chang, Rowland W. |
author_facet | Semanik, Pamela Lee, Jungwha Pellegrini, Christine A. Song, Jing Dunlop, Dorothy D. Chang, Rowland W. |
author_sort | Semanik, Pamela |
collection | PubMed |
description | OBJECTIVE: We examined the accuracy of data from an affordable personal monitor (Fitbit Flex) compared with that of data from a research‐grade accelerometer worn simultaneously for 7 days; high accuracy would support substitution with this less‐expensive personal activity monitor in future community‐based arthritis research. METHODS: Subjects (N = 35) with chronic knee symptoms were recruited for a pilot intervention study using Fitbits to increase physical activity in employees with chronic knee symptoms at an urban corporation. Subjects simultaneously wore for 7 days a Fitbit Flex (wrist‐worn) and ActiGraph GT3X+ (waist‐worn). Fitbit Flex data were regularly stored on a research storage service (Fitabase) by participants. Bland–Altman plots were constructed to examine the agreement between the mean daily times spent in light activity and in bouted moderate‐to‐vigorous physical activity (MVPA). Comparisons were calculated by matching Fitabase data from calendar days the Fitbit was worn with data from valid monitoring days (greater than or equal to 10 hours wear time) of the ActiGraph. RESULTS: Participants at baseline were mostly female (69%) and white (57%) and had a mean age of 52 years and body mass index of 32 kg/m(2). Bland–Altman analyses indicated systematic bias overall (the Fitbit overestimated both light‐intensity activity and MVPA compared with the ActiGraph). The average error varied in magnitude and direction with changing activity amounts. CONCLUSION: The Fitbit Flex does not appear to be an adequate substitute for research‐grade accelerometry (which represents the gold standard for objective research monitoring of all physical activity intensity levels) in this population of persons with chronic knee symptoms. |
format | Online Article Text |
id | pubmed-6957919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69579192020-01-17 Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms Semanik, Pamela Lee, Jungwha Pellegrini, Christine A. Song, Jing Dunlop, Dorothy D. Chang, Rowland W. ACR Open Rheumatol Brief Report OBJECTIVE: We examined the accuracy of data from an affordable personal monitor (Fitbit Flex) compared with that of data from a research‐grade accelerometer worn simultaneously for 7 days; high accuracy would support substitution with this less‐expensive personal activity monitor in future community‐based arthritis research. METHODS: Subjects (N = 35) with chronic knee symptoms were recruited for a pilot intervention study using Fitbits to increase physical activity in employees with chronic knee symptoms at an urban corporation. Subjects simultaneously wore for 7 days a Fitbit Flex (wrist‐worn) and ActiGraph GT3X+ (waist‐worn). Fitbit Flex data were regularly stored on a research storage service (Fitabase) by participants. Bland–Altman plots were constructed to examine the agreement between the mean daily times spent in light activity and in bouted moderate‐to‐vigorous physical activity (MVPA). Comparisons were calculated by matching Fitabase data from calendar days the Fitbit was worn with data from valid monitoring days (greater than or equal to 10 hours wear time) of the ActiGraph. RESULTS: Participants at baseline were mostly female (69%) and white (57%) and had a mean age of 52 years and body mass index of 32 kg/m(2). Bland–Altman analyses indicated systematic bias overall (the Fitbit overestimated both light‐intensity activity and MVPA compared with the ActiGraph). The average error varied in magnitude and direction with changing activity amounts. CONCLUSION: The Fitbit Flex does not appear to be an adequate substitute for research‐grade accelerometry (which represents the gold standard for objective research monitoring of all physical activity intensity levels) in this population of persons with chronic knee symptoms. John Wiley and Sons Inc. 2019-12-02 /pmc/articles/PMC6957919/ /pubmed/31943970 http://dx.doi.org/10.1002/acr2.11099 Text en © 2019 The Authors. ACR Open Rheumatology published by Wiley Periodicals, Inc. on behalf of American College of Rheumatology. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Brief Report Semanik, Pamela Lee, Jungwha Pellegrini, Christine A. Song, Jing Dunlop, Dorothy D. Chang, Rowland W. Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title | Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title_full | Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title_fullStr | Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title_full_unstemmed | Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title_short | Comparison of Physical Activity Measures Derived From the Fitbit Flex and the ActiGraph GT3X+ in an Employee Population With Chronic Knee Symptoms |
title_sort | comparison of physical activity measures derived from the fitbit flex and the actigraph gt3x+ in an employee population with chronic knee symptoms |
topic | Brief Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6957919/ https://www.ncbi.nlm.nih.gov/pubmed/31943970 http://dx.doi.org/10.1002/acr2.11099 |
work_keys_str_mv | AT semanikpamela comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms AT leejungwha comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms AT pellegrinichristinea comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms AT songjing comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms AT dunlopdorothyd comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms AT changrowlandw comparisonofphysicalactivitymeasuresderivedfromthefitbitflexandtheactigraphgt3xinanemployeepopulationwithchronickneesymptoms |