Cargando…

Modified long-axis in-plane ultrasound technique versus conventional palpation technique for radial arterial cannulation: A prospective randomized controlled trial

BACKGROUND: A low first-pass success rate of radial artery cannulation was obtained when using the conventional palpation technique (C-PT) or conventional ultrasound-guided techniques, we; therefore, evaluate the effect of a modified long-axis in-plane ultrasound technique (M-LAINUT) in guiding radi...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jiebo, Lai, Zhongmeng, Weng, Xianfeng, Lin, Yong, Wu, Guohua, Su, Jiansheng, Huang, Qijian, Zeng, Jian, Liu, Junle, Zhao, Zisong, Yan, Ting, Zhang, Liangcheng, Zhou, Linying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6959944/
https://www.ncbi.nlm.nih.gov/pubmed/31914094
http://dx.doi.org/10.1097/MD.0000000000018747
Descripción
Sumario:BACKGROUND: A low first-pass success rate of radial artery cannulation was obtained when using the conventional palpation technique (C-PT) or conventional ultrasound-guided techniques, we; therefore, evaluate the effect of a modified long-axis in-plane ultrasound technique (M-LAINUT) in guiding radial artery cannulation in adults. METHODS: We conducted a prospective, randomized and controlled clinical trial of 288 patients undergoing radial artery cannulation. Patients were randomized 1:1 to M-LAINUT or C-PT group at Fujian Medical University Union Hospital between 2017 and 2018. Radial artery cannulation was performed by 3 anesthesiologists with different experience. The outcome was the first and total radial artery cannulation success rates, the number of attempts and the cannulation time, and incidence of complications. RESULTS: Two hundred eighty-five patients were statistically analyzed. The success rate of first attempt was 91.6% in the M-LAINUT group (n = 143) and 57.7% in the C-PT group (n = 142; P < .001) (odds ratio, 7.9; 95% confidence interval, 4.0–15.7). The total success rate (≤5 minutes and ≤3 attempts) in the M-LAINUT group was 97.9%, compared to 84.5% in the palpation group (P < .001) (odds ratio, 8.5; 95% confidence interval, 2.5–29.2). The total cannulation time was shorter and the number of attempts was fewer in the M-LAINUT group than that in the C-PT group (P < .05). The incidence of hematoma in the C-PT group was 19.7%, which was significantly higher than the 2.8% in the M-LAINUT group (P < .001). CONCLUSIONS: Modified long-axis in-plane ultrasound-guided radial artery cannulation can increase the first and total radial artery cannulation success rates, reduce the number of attempts, and shorten the total cannulation time in adults.