Cargando…

A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture

This is a retrospective evaluated. The objective of this study was to test the interobserver reliability and intraobserver reproducibility of fracture classification with Arbeitsgemeinschaftfür Osteosynthesefragen (AO) system and Fernandez system used by 5 senior orthopedic surgeons. Anteroposterior...

Descripción completa

Detalles Bibliográficos
Autores principales: Yinjie, Yan, Gen, Wen, Hongbo, Wan, Chongqing, Xu, Fan, Zhaoxiang, Yanqi, Feng, Xuequn, Wu, Wen, Mo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6959948/
https://www.ncbi.nlm.nih.gov/pubmed/31914022
http://dx.doi.org/10.1097/MD.0000000000018508
_version_ 1783487686455066624
author Yinjie, Yan
Gen, Wen
Hongbo, Wan
Chongqing, Xu
Fan, Zhaoxiang
Yanqi, Feng
Xuequn, Wu
Wen, Mo
author_facet Yinjie, Yan
Gen, Wen
Hongbo, Wan
Chongqing, Xu
Fan, Zhaoxiang
Yanqi, Feng
Xuequn, Wu
Wen, Mo
author_sort Yinjie, Yan
collection PubMed
description This is a retrospective evaluated. The objective of this study was to test the interobserver reliability and intraobserver reproducibility of fracture classification with Arbeitsgemeinschaftfür Osteosynthesefragen (AO) system and Fernandez system used by 5 senior orthopedic surgeons. Anteroposterior and lateral radiographs of 160 patients hospitalized for displaced distal radius fracture were examined. Independently, 5 orthopedic surgeons evaluated the radiographs according to 2 different distal radius classification systems (3 types of results). Three statistical tools were used to measure interobserver reliability and intraobserver reproducibility. The intraclass correlation coefficient and kappa coefficient (k) were used to assess both interobserver and intraobserver agreement of AO and Fernandez. Kappa value indicated poor agreement (<0), slight (0–0.20), fair (0.21–0.40), moderate (0.41–0.60), good (0.61–0.80), and perfect (0.81–1.00). The intraobserver reproducibility of AO system (9 types) and Fernandez system were moderate with a value of 0.577 and 0.438. The intraobserver reproducibility of AO system (27 subtypes) was 0.286. The interobserver reliability of AO system (9 types) was moderate with a value of 0.469 and that of Fernandez was moderate with a value of 0.435. The interobserver reliability of AO system (27 subtypes) was 0.299. Neither of the 2 systems can give us a satisfactory agreement between interobserver reliability and intraobserver reproducibility. In AO system, the interobserver reliability and intraobserver reproducibility of the 9 types decreased with the increase of subgroups.
format Online
Article
Text
id pubmed-6959948
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-69599482020-01-31 A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture Yinjie, Yan Gen, Wen Hongbo, Wan Chongqing, Xu Fan, Zhaoxiang Yanqi, Feng Xuequn, Wu Wen, Mo Medicine (Baltimore) 5400 This is a retrospective evaluated. The objective of this study was to test the interobserver reliability and intraobserver reproducibility of fracture classification with Arbeitsgemeinschaftfür Osteosynthesefragen (AO) system and Fernandez system used by 5 senior orthopedic surgeons. Anteroposterior and lateral radiographs of 160 patients hospitalized for displaced distal radius fracture were examined. Independently, 5 orthopedic surgeons evaluated the radiographs according to 2 different distal radius classification systems (3 types of results). Three statistical tools were used to measure interobserver reliability and intraobserver reproducibility. The intraclass correlation coefficient and kappa coefficient (k) were used to assess both interobserver and intraobserver agreement of AO and Fernandez. Kappa value indicated poor agreement (<0), slight (0–0.20), fair (0.21–0.40), moderate (0.41–0.60), good (0.61–0.80), and perfect (0.81–1.00). The intraobserver reproducibility of AO system (9 types) and Fernandez system were moderate with a value of 0.577 and 0.438. The intraobserver reproducibility of AO system (27 subtypes) was 0.286. The interobserver reliability of AO system (9 types) was moderate with a value of 0.469 and that of Fernandez was moderate with a value of 0.435. The interobserver reliability of AO system (27 subtypes) was 0.299. Neither of the 2 systems can give us a satisfactory agreement between interobserver reliability and intraobserver reproducibility. In AO system, the interobserver reliability and intraobserver reproducibility of the 9 types decreased with the increase of subgroups. Wolters Kluwer Health 2020-01-10 /pmc/articles/PMC6959948/ /pubmed/31914022 http://dx.doi.org/10.1097/MD.0000000000018508 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 5400
Yinjie, Yan
Gen, Wen
Hongbo, Wan
Chongqing, Xu
Fan, Zhaoxiang
Yanqi, Feng
Xuequn, Wu
Wen, Mo
A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title_full A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title_fullStr A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title_full_unstemmed A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title_short A retrospective evaluation of reliability and reproducibility of Arbeitsgemeinschaftfür Osteosynthesefragen classification and Fernandez classification for distal radius fracture
title_sort retrospective evaluation of reliability and reproducibility of arbeitsgemeinschaftfür osteosynthesefragen classification and fernandez classification for distal radius fracture
topic 5400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6959948/
https://www.ncbi.nlm.nih.gov/pubmed/31914022
http://dx.doi.org/10.1097/MD.0000000000018508
work_keys_str_mv AT yinjieyan aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT genwen aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT hongbowan aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT chongqingxu aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT fanzhaoxiang aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT yanqifeng aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT xuequnwu aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT wenmo aretrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT yinjieyan retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT genwen retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT hongbowan retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT chongqingxu retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT fanzhaoxiang retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT yanqifeng retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT xuequnwu retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture
AT wenmo retrospectiveevaluationofreliabilityandreproducibilityofarbeitsgemeinschaftfurosteosynthesefragenclassificationandfernandezclassificationfordistalradiusfracture