Cargando…

Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria

OBJECTIVE: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of si...

Descripción completa

Detalles Bibliográficos
Autores principales: Yim, Younghee, Na, Dong Gyu, Ha, Eun Ju, Baek, Jung Hwan, Sung, Jin Yong, Kim, Ji-hoon, Moon, Won-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960308/
https://www.ncbi.nlm.nih.gov/pubmed/31920034
http://dx.doi.org/10.3348/kjr.2019.0215
_version_ 1783487766340829184
author Yim, Younghee
Na, Dong Gyu
Ha, Eun Ju
Baek, Jung Hwan
Sung, Jin Yong
Kim, Ji-hoon
Moon, Won-Jin
author_facet Yim, Younghee
Na, Dong Gyu
Ha, Eun Ju
Baek, Jung Hwan
Sung, Jin Yong
Kim, Ji-hoon
Moon, Won-Jin
author_sort Yim, Younghee
collection PubMed
description OBJECTIVE: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies. MATERIALS AND METHODS: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated. RESULTS: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1–100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8–83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7–19.8%, 0–40.9%, and 0.1–30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0–5.9%, 0–10.9%, and 0.1–8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0–33.8%), decreased with the simulated biopsy size criteria (0–8.7%). CONCLUSION: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.
format Online
Article
Text
id pubmed-6960308
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-69603082020-01-22 Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria Yim, Younghee Na, Dong Gyu Ha, Eun Ju Baek, Jung Hwan Sung, Jin Yong Kim, Ji-hoon Moon, Won-Jin Korean J Radiol Thyroid OBJECTIVE: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies. MATERIALS AND METHODS: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated. RESULTS: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1–100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8–83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7–19.8%, 0–40.9%, and 0.1–30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0–5.9%, 0–10.9%, and 0.1–8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0–33.8%), decreased with the simulated biopsy size criteria (0–8.7%). CONCLUSION: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies. The Korean Society of Radiology 2020-01 2019-12-16 /pmc/articles/PMC6960308/ /pubmed/31920034 http://dx.doi.org/10.3348/kjr.2019.0215 Text en Copyright © 2020 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thyroid
Yim, Younghee
Na, Dong Gyu
Ha, Eun Ju
Baek, Jung Hwan
Sung, Jin Yong
Kim, Ji-hoon
Moon, Won-Jin
Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title_full Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title_fullStr Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title_full_unstemmed Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title_short Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
title_sort concordance of three international guidelines for thyroid nodules classified by ultrasonography and diagnostic performance of biopsy criteria
topic Thyroid
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960308/
https://www.ncbi.nlm.nih.gov/pubmed/31920034
http://dx.doi.org/10.3348/kjr.2019.0215
work_keys_str_mv AT yimyounghee concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT nadonggyu concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT haeunju concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT baekjunghwan concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT sungjinyong concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT kimjihoon concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria
AT moonwonjin concordanceofthreeinternationalguidelinesforthyroidnodulesclassifiedbyultrasonographyanddiagnosticperformanceofbiopsycriteria