Cargando…
Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960534/ https://www.ncbi.nlm.nih.gov/pubmed/31835543 http://dx.doi.org/10.3390/s19245441 |
_version_ | 1783487792730341376 |
---|---|
author | Han, Sangjin Roh, Donggeun Park, Junyung Shin, Hangsik |
author_facet | Han, Sangjin Roh, Donggeun Park, Junyung Shin, Hangsik |
author_sort | Han, Sangjin |
collection | PubMed |
description | The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that can measure photoplethysmogram while using multiple wavelengths, and describe implementation detail. The developed sensor is manufactured by making a hole in a metal plate and mounting an LED therein, and it has four wavelength LEDs of blue (460 nm), green (530 nm), red (660 nm), and IR (940 nm), being arranged concentrically around a photodetector. Irradiation light intensity was measured by photoluminescent test, and photoplethymogram was measured with each wavelength simultaneously at a periphery of the human body such as fingertip, earlobe, toe, forehead, and wrist, in order to evaluate the developed sensor. As a result, the developed sensor module showed a linear increase of irradiating light intensity according to the number of LEDs increases, and pulsatile waveforms were observed at all four wavelengths in all measuring sites. |
format | Online Article Text |
id | pubmed-6960534 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69605342020-01-23 Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography Han, Sangjin Roh, Donggeun Park, Junyung Shin, Hangsik Sensors (Basel) Article The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that can measure photoplethysmogram while using multiple wavelengths, and describe implementation detail. The developed sensor is manufactured by making a hole in a metal plate and mounting an LED therein, and it has four wavelength LEDs of blue (460 nm), green (530 nm), red (660 nm), and IR (940 nm), being arranged concentrically around a photodetector. Irradiation light intensity was measured by photoluminescent test, and photoplethymogram was measured with each wavelength simultaneously at a periphery of the human body such as fingertip, earlobe, toe, forehead, and wrist, in order to evaluate the developed sensor. As a result, the developed sensor module showed a linear increase of irradiating light intensity according to the number of LEDs increases, and pulsatile waveforms were observed at all four wavelengths in all measuring sites. MDPI 2019-12-10 /pmc/articles/PMC6960534/ /pubmed/31835543 http://dx.doi.org/10.3390/s19245441 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Han, Sangjin Roh, Donggeun Park, Junyung Shin, Hangsik Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title | Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title_full | Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title_fullStr | Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title_full_unstemmed | Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title_short | Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography |
title_sort | design of multi-wavelength optical sensor module for depth-dependent photoplethysmography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960534/ https://www.ncbi.nlm.nih.gov/pubmed/31835543 http://dx.doi.org/10.3390/s19245441 |
work_keys_str_mv | AT hansangjin designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography AT rohdonggeun designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography AT parkjunyung designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography AT shinhangsik designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography |