Cargando…

Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography

The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that c...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Sangjin, Roh, Donggeun, Park, Junyung, Shin, Hangsik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960534/
https://www.ncbi.nlm.nih.gov/pubmed/31835543
http://dx.doi.org/10.3390/s19245441
_version_ 1783487792730341376
author Han, Sangjin
Roh, Donggeun
Park, Junyung
Shin, Hangsik
author_facet Han, Sangjin
Roh, Donggeun
Park, Junyung
Shin, Hangsik
author_sort Han, Sangjin
collection PubMed
description The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that can measure photoplethysmogram while using multiple wavelengths, and describe implementation detail. The developed sensor is manufactured by making a hole in a metal plate and mounting an LED therein, and it has four wavelength LEDs of blue (460 nm), green (530 nm), red (660 nm), and IR (940 nm), being arranged concentrically around a photodetector. Irradiation light intensity was measured by photoluminescent test, and photoplethymogram was measured with each wavelength simultaneously at a periphery of the human body such as fingertip, earlobe, toe, forehead, and wrist, in order to evaluate the developed sensor. As a result, the developed sensor module showed a linear increase of irradiating light intensity according to the number of LEDs increases, and pulsatile waveforms were observed at all four wavelengths in all measuring sites.
format Online
Article
Text
id pubmed-6960534
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69605342020-01-23 Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography Han, Sangjin Roh, Donggeun Park, Junyung Shin, Hangsik Sensors (Basel) Article The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that can measure photoplethysmogram while using multiple wavelengths, and describe implementation detail. The developed sensor is manufactured by making a hole in a metal plate and mounting an LED therein, and it has four wavelength LEDs of blue (460 nm), green (530 nm), red (660 nm), and IR (940 nm), being arranged concentrically around a photodetector. Irradiation light intensity was measured by photoluminescent test, and photoplethymogram was measured with each wavelength simultaneously at a periphery of the human body such as fingertip, earlobe, toe, forehead, and wrist, in order to evaluate the developed sensor. As a result, the developed sensor module showed a linear increase of irradiating light intensity according to the number of LEDs increases, and pulsatile waveforms were observed at all four wavelengths in all measuring sites. MDPI 2019-12-10 /pmc/articles/PMC6960534/ /pubmed/31835543 http://dx.doi.org/10.3390/s19245441 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Han, Sangjin
Roh, Donggeun
Park, Junyung
Shin, Hangsik
Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title_full Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title_fullStr Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title_full_unstemmed Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title_short Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
title_sort design of multi-wavelength optical sensor module for depth-dependent photoplethysmography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960534/
https://www.ncbi.nlm.nih.gov/pubmed/31835543
http://dx.doi.org/10.3390/s19245441
work_keys_str_mv AT hansangjin designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography
AT rohdonggeun designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography
AT parkjunyung designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography
AT shinhangsik designofmultiwavelengthopticalsensormodulefordepthdependentphotoplethysmography