Cargando…

Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing

A novel in-fiber Mach-Zehnder interferometer based on cascaded up-down-taper (UDT) structure is proposed by sandwiching a piece of polarization maintaining fiber between two single-mode fibers (SMF) and by utilizing over-fusion splicing method. The dual up tapers respectively act as fiber splitter/c...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Xiaopeng, Liu, Chunyu, Jiang, Shengxu, Leng, Shuo, Yang, Jiuru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960560/
https://www.ncbi.nlm.nih.gov/pubmed/31835516
http://dx.doi.org/10.3390/s19245440
_version_ 1783487798904356864
author Han, Xiaopeng
Liu, Chunyu
Jiang, Shengxu
Leng, Shuo
Yang, Jiuru
author_facet Han, Xiaopeng
Liu, Chunyu
Jiang, Shengxu
Leng, Shuo
Yang, Jiuru
author_sort Han, Xiaopeng
collection PubMed
description A novel in-fiber Mach-Zehnder interferometer based on cascaded up-down-taper (UDT) structure is proposed by sandwiching a piece of polarization maintaining fiber between two single-mode fibers (SMF) and by utilizing over-fusion splicing method. The dual up tapers respectively act as fiber splitter/combiner, the down taper acts as an optical attenuator. The structure parameters are analyzed and optimized. A larger interference fringe extinction ratio ~15 dB is obtained to achieve refractive index (RI) sensing based on intensity demodulation. The experimental results show that the RI sensitivity is −310.40 dB/RIU with the linearity is improved to 0.99 in the range of 1.3164–1.3444. The corresponding resolution can reach 3.22 × 10(−5) RIU, which is 6.8 times higher than wavelength demodulation. The cross sensitivity which caused by temperature fluctuation is less than 1.4 × 10(−4).
format Online
Article
Text
id pubmed-6960560
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69605602020-01-23 Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing Han, Xiaopeng Liu, Chunyu Jiang, Shengxu Leng, Shuo Yang, Jiuru Sensors (Basel) Article A novel in-fiber Mach-Zehnder interferometer based on cascaded up-down-taper (UDT) structure is proposed by sandwiching a piece of polarization maintaining fiber between two single-mode fibers (SMF) and by utilizing over-fusion splicing method. The dual up tapers respectively act as fiber splitter/combiner, the down taper acts as an optical attenuator. The structure parameters are analyzed and optimized. A larger interference fringe extinction ratio ~15 dB is obtained to achieve refractive index (RI) sensing based on intensity demodulation. The experimental results show that the RI sensitivity is −310.40 dB/RIU with the linearity is improved to 0.99 in the range of 1.3164–1.3444. The corresponding resolution can reach 3.22 × 10(−5) RIU, which is 6.8 times higher than wavelength demodulation. The cross sensitivity which caused by temperature fluctuation is less than 1.4 × 10(−4). MDPI 2019-12-10 /pmc/articles/PMC6960560/ /pubmed/31835516 http://dx.doi.org/10.3390/s19245440 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Han, Xiaopeng
Liu, Chunyu
Jiang, Shengxu
Leng, Shuo
Yang, Jiuru
Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title_full Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title_fullStr Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title_full_unstemmed Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title_short Up-down Taper Based In-Fiber Mach-Zehnder Interferometer for Liquid Refractive Index Sensing
title_sort up-down taper based in-fiber mach-zehnder interferometer for liquid refractive index sensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960560/
https://www.ncbi.nlm.nih.gov/pubmed/31835516
http://dx.doi.org/10.3390/s19245440
work_keys_str_mv AT hanxiaopeng updowntaperbasedinfibermachzehnderinterferometerforliquidrefractiveindexsensing
AT liuchunyu updowntaperbasedinfibermachzehnderinterferometerforliquidrefractiveindexsensing
AT jiangshengxu updowntaperbasedinfibermachzehnderinterferometerforliquidrefractiveindexsensing
AT lengshuo updowntaperbasedinfibermachzehnderinterferometerforliquidrefractiveindexsensing
AT yangjiuru updowntaperbasedinfibermachzehnderinterferometerforliquidrefractiveindexsensing