Cargando…
Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electro...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960938/ https://www.ncbi.nlm.nih.gov/pubmed/31888286 http://dx.doi.org/10.3390/s19245560 |
_version_ | 1783487884977766400 |
---|---|
author | Chinnadayyala, Somasekhar R. Park, Jinsoo Kim, Young Hyo Choi, Seong Hye Lee, Sang-Myung Cho, Won Woo Lee, Ga-Yeon Pyun, Jae-Chul Cho, Sungbo |
author_facet | Chinnadayyala, Somasekhar R. Park, Jinsoo Kim, Young Hyo Choi, Seong Hye Lee, Sang-Myung Cho, Won Woo Lee, Ga-Yeon Pyun, Jae-Chul Cho, Sungbo |
author_sort | Chinnadayyala, Somasekhar R. |
collection | PubMed |
description | An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL(−1). The electrode showed detection limits of 0.025 ng mL(−1) and 0.23 ng mL(−1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS. |
format | Online Article Text |
id | pubmed-6960938 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69609382020-01-24 Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode Chinnadayyala, Somasekhar R. Park, Jinsoo Kim, Young Hyo Choi, Seong Hye Lee, Sang-Myung Cho, Won Woo Lee, Ga-Yeon Pyun, Jae-Chul Cho, Sungbo Sensors (Basel) Article An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL(−1). The electrode showed detection limits of 0.025 ng mL(−1) and 0.23 ng mL(−1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS. MDPI 2019-12-16 /pmc/articles/PMC6960938/ /pubmed/31888286 http://dx.doi.org/10.3390/s19245560 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chinnadayyala, Somasekhar R. Park, Jinsoo Kim, Young Hyo Choi, Seong Hye Lee, Sang-Myung Cho, Won Woo Lee, Ga-Yeon Pyun, Jae-Chul Cho, Sungbo Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title | Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title_full | Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title_fullStr | Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title_full_unstemmed | Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title_short | Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode |
title_sort | electrochemical detection of c-reactive protein in human serum based on self-assembled monolayer-modified interdigitated wave-shaped electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960938/ https://www.ncbi.nlm.nih.gov/pubmed/31888286 http://dx.doi.org/10.3390/s19245560 |
work_keys_str_mv | AT chinnadayyalasomasekharr electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT parkjinsoo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT kimyounghyo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT choiseonghye electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT leesangmyung electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT chowonwoo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT leegayeon electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT pyunjaechul electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode AT chosungbo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode |