Cargando…

Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode

An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electro...

Descripción completa

Detalles Bibliográficos
Autores principales: Chinnadayyala, Somasekhar R., Park, Jinsoo, Kim, Young Hyo, Choi, Seong Hye, Lee, Sang-Myung, Cho, Won Woo, Lee, Ga-Yeon, Pyun, Jae-Chul, Cho, Sungbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960938/
https://www.ncbi.nlm.nih.gov/pubmed/31888286
http://dx.doi.org/10.3390/s19245560
_version_ 1783487884977766400
author Chinnadayyala, Somasekhar R.
Park, Jinsoo
Kim, Young Hyo
Choi, Seong Hye
Lee, Sang-Myung
Cho, Won Woo
Lee, Ga-Yeon
Pyun, Jae-Chul
Cho, Sungbo
author_facet Chinnadayyala, Somasekhar R.
Park, Jinsoo
Kim, Young Hyo
Choi, Seong Hye
Lee, Sang-Myung
Cho, Won Woo
Lee, Ga-Yeon
Pyun, Jae-Chul
Cho, Sungbo
author_sort Chinnadayyala, Somasekhar R.
collection PubMed
description An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL(−1). The electrode showed detection limits of 0.025 ng mL(−1) and 0.23 ng mL(−1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS.
format Online
Article
Text
id pubmed-6960938
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69609382020-01-24 Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode Chinnadayyala, Somasekhar R. Park, Jinsoo Kim, Young Hyo Choi, Seong Hye Lee, Sang-Myung Cho, Won Woo Lee, Ga-Yeon Pyun, Jae-Chul Cho, Sungbo Sensors (Basel) Article An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL(−1). The electrode showed detection limits of 0.025 ng mL(−1) and 0.23 ng mL(−1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS. MDPI 2019-12-16 /pmc/articles/PMC6960938/ /pubmed/31888286 http://dx.doi.org/10.3390/s19245560 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chinnadayyala, Somasekhar R.
Park, Jinsoo
Kim, Young Hyo
Choi, Seong Hye
Lee, Sang-Myung
Cho, Won Woo
Lee, Ga-Yeon
Pyun, Jae-Chul
Cho, Sungbo
Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title_full Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title_fullStr Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title_full_unstemmed Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title_short Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
title_sort electrochemical detection of c-reactive protein in human serum based on self-assembled monolayer-modified interdigitated wave-shaped electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960938/
https://www.ncbi.nlm.nih.gov/pubmed/31888286
http://dx.doi.org/10.3390/s19245560
work_keys_str_mv AT chinnadayyalasomasekharr electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT parkjinsoo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT kimyounghyo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT choiseonghye electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT leesangmyung electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT chowonwoo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT leegayeon electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT pyunjaechul electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode
AT chosungbo electrochemicaldetectionofcreactiveproteininhumanserumbasedonselfassembledmonolayermodifiedinterdigitatedwaveshapedelectrode