Cargando…
An Accurate Calibration Means for the Phase Measuring Deflectometry System
Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefo...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6961048/ https://www.ncbi.nlm.nih.gov/pubmed/31817527 http://dx.doi.org/10.3390/s19245377 |
_version_ | 1783487910559875072 |
---|---|
author | Han, Hao Wu, Shiqian Song, Zhan |
author_facet | Han, Hao Wu, Shiqian Song, Zhan |
author_sort | Han, Hao |
collection | PubMed |
description | Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefore, an accurate and practical calibration method is proposed. In which, conventional calibration means is first applied for the primary calibration. Then, a precise square planar mirror is used for the optimization of system calibration parameters. All the intrinsic and extrinsic parameters are considered as a global multi-objective optimization problem. Three metric error criteria are introduced to evaluate the 3D reconstruction accuracy of the reference mirror. Compared with classical calibration means, which apply the parameter optimization in 2D image space to minimize the re-projection errors, the proposed optimization approach is executed in 3D space directly. An experiment and comparison are conducted to verify that the proposed optimal calibration approach can effectively reduce the system deviation and to improve the system measurement accuracy. |
format | Online Article Text |
id | pubmed-6961048 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69610482020-01-24 An Accurate Calibration Means for the Phase Measuring Deflectometry System Han, Hao Wu, Shiqian Song, Zhan Sensors (Basel) Article Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefore, an accurate and practical calibration method is proposed. In which, conventional calibration means is first applied for the primary calibration. Then, a precise square planar mirror is used for the optimization of system calibration parameters. All the intrinsic and extrinsic parameters are considered as a global multi-objective optimization problem. Three metric error criteria are introduced to evaluate the 3D reconstruction accuracy of the reference mirror. Compared with classical calibration means, which apply the parameter optimization in 2D image space to minimize the re-projection errors, the proposed optimization approach is executed in 3D space directly. An experiment and comparison are conducted to verify that the proposed optimal calibration approach can effectively reduce the system deviation and to improve the system measurement accuracy. MDPI 2019-12-05 /pmc/articles/PMC6961048/ /pubmed/31817527 http://dx.doi.org/10.3390/s19245377 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Han, Hao Wu, Shiqian Song, Zhan An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title | An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title_full | An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title_fullStr | An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title_full_unstemmed | An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title_short | An Accurate Calibration Means for the Phase Measuring Deflectometry System |
title_sort | accurate calibration means for the phase measuring deflectometry system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6961048/ https://www.ncbi.nlm.nih.gov/pubmed/31817527 http://dx.doi.org/10.3390/s19245377 |
work_keys_str_mv | AT hanhao anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem AT wushiqian anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem AT songzhan anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem AT hanhao accuratecalibrationmeansforthephasemeasuringdeflectometrysystem AT wushiqian accuratecalibrationmeansforthephasemeasuringdeflectometrysystem AT songzhan accuratecalibrationmeansforthephasemeasuringdeflectometrysystem |