Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefo...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Hao, Wu, Shiqian, Song, Zhan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6961048/
https://www.ncbi.nlm.nih.gov/pubmed/31817527
http://dx.doi.org/10.3390/s19245377
_version_ 1783487910559875072
author Han, Hao
Wu, Shiqian
Song, Zhan
author_facet Han, Hao
Wu, Shiqian
Song, Zhan
author_sort Han, Hao
collection PubMed
description Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefore, an accurate and practical calibration method is proposed. In which, conventional calibration means is first applied for the primary calibration. Then, a precise square planar mirror is used for the optimization of system calibration parameters. All the intrinsic and extrinsic parameters are considered as a global multi-objective optimization problem. Three metric error criteria are introduced to evaluate the 3D reconstruction accuracy of the reference mirror. Compared with classical calibration means, which apply the parameter optimization in 2D image space to minimize the re-projection errors, the proposed optimization approach is executed in 3D space directly. An experiment and comparison are conducted to verify that the proposed optimal calibration approach can effectively reduce the system deviation and to improve the system measurement accuracy.
format Online
Article
Text
id pubmed-6961048
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69610482020-01-24 An Accurate Calibration Means for the Phase Measuring Deflectometry System Han, Hao Wu, Shiqian Song, Zhan Sensors (Basel) Article Calibration is a critical step for the phase measuring deflectometry system. Existing calibration methods are mainly optimizing the calibration parameters with respect to the 2D re-projection error criterion. However, such a procedure cannot reduce metric errors in the practical application. Therefore, an accurate and practical calibration method is proposed. In which, conventional calibration means is first applied for the primary calibration. Then, a precise square planar mirror is used for the optimization of system calibration parameters. All the intrinsic and extrinsic parameters are considered as a global multi-objective optimization problem. Three metric error criteria are introduced to evaluate the 3D reconstruction accuracy of the reference mirror. Compared with classical calibration means, which apply the parameter optimization in 2D image space to minimize the re-projection errors, the proposed optimization approach is executed in 3D space directly. An experiment and comparison are conducted to verify that the proposed optimal calibration approach can effectively reduce the system deviation and to improve the system measurement accuracy. MDPI 2019-12-05 /pmc/articles/PMC6961048/ /pubmed/31817527 http://dx.doi.org/10.3390/s19245377 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Han, Hao
Wu, Shiqian
Song, Zhan
An Accurate Calibration Means for the Phase Measuring Deflectometry System
title An Accurate Calibration Means for the Phase Measuring Deflectometry System
title_full An Accurate Calibration Means for the Phase Measuring Deflectometry System
title_fullStr An Accurate Calibration Means for the Phase Measuring Deflectometry System
title_full_unstemmed An Accurate Calibration Means for the Phase Measuring Deflectometry System
title_short An Accurate Calibration Means for the Phase Measuring Deflectometry System
title_sort accurate calibration means for the phase measuring deflectometry system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6961048/
https://www.ncbi.nlm.nih.gov/pubmed/31817527
http://dx.doi.org/10.3390/s19245377
work_keys_str_mv AT hanhao anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem
AT wushiqian anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem
AT songzhan anaccuratecalibrationmeansforthephasemeasuringdeflectometrysystem
AT hanhao accuratecalibrationmeansforthephasemeasuringdeflectometrysystem
AT wushiqian accuratecalibrationmeansforthephasemeasuringdeflectometrysystem
AT songzhan accuratecalibrationmeansforthephasemeasuringdeflectometrysystem