Cargando…
Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavir...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962121/ https://www.ncbi.nlm.nih.gov/pubmed/31506730 http://dx.doi.org/10.1007/s10096-019-03697-7 |
_version_ | 1783488097103642624 |
---|---|
author | Kulis-Horn, Robert K. Tiemann, Carsten |
author_facet | Kulis-Horn, Robert K. Tiemann, Carsten |
author_sort | Kulis-Horn, Robert K. |
collection | PubMed |
description | The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavirus from stool samples on this system. The LDT was optimized for primer and probe sequences, salt concentration, and PCR annealing temperature. Reproducibility of the PCR and extraction process was assessed. Performance of the multiplex LDT assay was evaluated with external quality assessment (EQA) samples and compared to a commercial multiplex assay (Allplex™ GI-Virus Assay, Seegene) in clinical samples. Salt concentrations and annealing/extension temperature were optimized to 4 mM MgCl(2), 70 mM KCl, 20 mM Tris, and 60 °C, respectively. The user-prepared part of the LDT PCR mix (containing salts, probes, and primers) was stable for ≥ 11 days onboard the instrument. We observed reproducible results of PCR and the extraction process. The LDT had a sensitivity comparable to or greater than the commercial Allplex™ assay and showed excellent linearity. Forty-five EQA samples yielded the expected result with the LDT. There was 100% concordance between LDT and Allplex™ results in 160 clinical samples. Results from the suspension and direct swab stool sample preparation methods were highly concordant in the LDT. We report the successful development and validation of a multiplex PCR LDT for detection of norovirus G1, norovirus G2, and rotavirus from stool samples on the Panther Fusion® system. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10096-019-03697-7) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6962121 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-69621212020-01-30 Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system Kulis-Horn, Robert K. Tiemann, Carsten Eur J Clin Microbiol Infect Dis Original Article The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavirus from stool samples on this system. The LDT was optimized for primer and probe sequences, salt concentration, and PCR annealing temperature. Reproducibility of the PCR and extraction process was assessed. Performance of the multiplex LDT assay was evaluated with external quality assessment (EQA) samples and compared to a commercial multiplex assay (Allplex™ GI-Virus Assay, Seegene) in clinical samples. Salt concentrations and annealing/extension temperature were optimized to 4 mM MgCl(2), 70 mM KCl, 20 mM Tris, and 60 °C, respectively. The user-prepared part of the LDT PCR mix (containing salts, probes, and primers) was stable for ≥ 11 days onboard the instrument. We observed reproducible results of PCR and the extraction process. The LDT had a sensitivity comparable to or greater than the commercial Allplex™ assay and showed excellent linearity. Forty-five EQA samples yielded the expected result with the LDT. There was 100% concordance between LDT and Allplex™ results in 160 clinical samples. Results from the suspension and direct swab stool sample preparation methods were highly concordant in the LDT. We report the successful development and validation of a multiplex PCR LDT for detection of norovirus G1, norovirus G2, and rotavirus from stool samples on the Panther Fusion® system. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10096-019-03697-7) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-10 2020 /pmc/articles/PMC6962121/ /pubmed/31506730 http://dx.doi.org/10.1007/s10096-019-03697-7 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Kulis-Horn, Robert K. Tiemann, Carsten Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title | Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title_full | Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title_fullStr | Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title_full_unstemmed | Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title_short | Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system |
title_sort | evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time rt-pcr on the panther fusion® system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962121/ https://www.ncbi.nlm.nih.gov/pubmed/31506730 http://dx.doi.org/10.1007/s10096-019-03697-7 |
work_keys_str_mv | AT kulishornrobertk evaluationofalaboratorydevelopedtestforsimultaneousdetectionofnorovirusandrotavirusbyrealtimertpcronthepantherfusionsystem AT tiemanncarsten evaluationofalaboratorydevelopedtestforsimultaneousdetectionofnorovirusandrotavirusbyrealtimertpcronthepantherfusionsystem |