Cargando…

Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system

The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavir...

Descripción completa

Detalles Bibliográficos
Autores principales: Kulis-Horn, Robert K., Tiemann, Carsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962121/
https://www.ncbi.nlm.nih.gov/pubmed/31506730
http://dx.doi.org/10.1007/s10096-019-03697-7
_version_ 1783488097103642624
author Kulis-Horn, Robert K.
Tiemann, Carsten
author_facet Kulis-Horn, Robert K.
Tiemann, Carsten
author_sort Kulis-Horn, Robert K.
collection PubMed
description The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavirus from stool samples on this system. The LDT was optimized for primer and probe sequences, salt concentration, and PCR annealing temperature. Reproducibility of the PCR and extraction process was assessed. Performance of the multiplex LDT assay was evaluated with external quality assessment (EQA) samples and compared to a commercial multiplex assay (Allplex™ GI-Virus Assay, Seegene) in clinical samples. Salt concentrations and annealing/extension temperature were optimized to 4 mM MgCl(2), 70 mM KCl, 20 mM Tris, and 60 °C, respectively. The user-prepared part of the LDT PCR mix (containing salts, probes, and primers) was stable for ≥ 11 days onboard the instrument. We observed reproducible results of PCR and the extraction process. The LDT had a sensitivity comparable to or greater than the commercial Allplex™ assay and showed excellent linearity. Forty-five EQA samples yielded the expected result with the LDT. There was 100% concordance between LDT and Allplex™ results in 160 clinical samples. Results from the suspension and direct swab stool sample preparation methods were highly concordant in the LDT. We report the successful development and validation of a multiplex PCR LDT for detection of norovirus G1, norovirus G2, and rotavirus from stool samples on the Panther Fusion® system. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10096-019-03697-7) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6962121
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-69621212020-01-30 Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system Kulis-Horn, Robert K. Tiemann, Carsten Eur J Clin Microbiol Infect Dis Original Article The Hologic Panther Fusion® Open Access™ functionality allows implementation of laboratory-developed tests (LDTs), with fully automated sample extraction, real-time PCR, and result interpretation. We report the development and validation of a multiplex LDT for norovirus G1, norovirus G2, and rotavirus from stool samples on this system. The LDT was optimized for primer and probe sequences, salt concentration, and PCR annealing temperature. Reproducibility of the PCR and extraction process was assessed. Performance of the multiplex LDT assay was evaluated with external quality assessment (EQA) samples and compared to a commercial multiplex assay (Allplex™ GI-Virus Assay, Seegene) in clinical samples. Salt concentrations and annealing/extension temperature were optimized to 4 mM MgCl(2), 70 mM KCl, 20 mM Tris, and 60 °C, respectively. The user-prepared part of the LDT PCR mix (containing salts, probes, and primers) was stable for ≥ 11 days onboard the instrument. We observed reproducible results of PCR and the extraction process. The LDT had a sensitivity comparable to or greater than the commercial Allplex™ assay and showed excellent linearity. Forty-five EQA samples yielded the expected result with the LDT. There was 100% concordance between LDT and Allplex™ results in 160 clinical samples. Results from the suspension and direct swab stool sample preparation methods were highly concordant in the LDT. We report the successful development and validation of a multiplex PCR LDT for detection of norovirus G1, norovirus G2, and rotavirus from stool samples on the Panther Fusion® system. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10096-019-03697-7) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-10 2020 /pmc/articles/PMC6962121/ /pubmed/31506730 http://dx.doi.org/10.1007/s10096-019-03697-7 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Kulis-Horn, Robert K.
Tiemann, Carsten
Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title_full Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title_fullStr Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title_full_unstemmed Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title_short Evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time RT-PCR on the Panther Fusion® system
title_sort evaluation of a laboratory-developed test for simultaneous detection of norovirus and rotavirus by real-time rt-pcr on the panther fusion® system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962121/
https://www.ncbi.nlm.nih.gov/pubmed/31506730
http://dx.doi.org/10.1007/s10096-019-03697-7
work_keys_str_mv AT kulishornrobertk evaluationofalaboratorydevelopedtestforsimultaneousdetectionofnorovirusandrotavirusbyrealtimertpcronthepantherfusionsystem
AT tiemanncarsten evaluationofalaboratorydevelopedtestforsimultaneousdetectionofnorovirusandrotavirusbyrealtimertpcronthepantherfusionsystem