Cargando…

Impact of contouring variability on oncological PET radiomics features in the lung

Radiomics features extracted from oncological PET images are currently under intense scrutiny within the context of risk stratification for a variety of cancers. However, the lack of robustness assessment poses problems for their application across institutions and for broader patient populations. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, F., Simpson, G., Young, L., Ford, J., Dogan, N., Wang, L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962150/
https://www.ncbi.nlm.nih.gov/pubmed/31941949
http://dx.doi.org/10.1038/s41598-019-57171-7
_version_ 1783488103977058304
author Yang, F.
Simpson, G.
Young, L.
Ford, J.
Dogan, N.
Wang, L.
author_facet Yang, F.
Simpson, G.
Young, L.
Ford, J.
Dogan, N.
Wang, L.
author_sort Yang, F.
collection PubMed
description Radiomics features extracted from oncological PET images are currently under intense scrutiny within the context of risk stratification for a variety of cancers. However, the lack of robustness assessment poses problems for their application across institutions and for broader patient populations. The objective of the current study was to examine the extent to which radiomics parameters from oncological PET vary in response to manual contouring variability in lung cancer. Imaging data employed in the study consisted of 26 PET scans with lesions in the lung being created through the use of an anthropomorphic phantom in conjunction with Monte Carlo simulations. From each of the simulated lesions, 25 radiomics features related to the gray-level co-occurrence matrices (GLCOM), gray-level size zone matrices (GLSZM), and gray-level neighborhood difference matrices (GLNDM) were extracted from ground truth contour and from manual contours provided by 10 raters in regard to four intensity discretization schemes with number of gray levels of 32, 64, 128, and 256, respectively. The impact of interrater variability in tumor delineation upon the agreement between raters on radiomics features was examined via interclass correlation and leave-p-out assessment. Only weak and moderate correlations were found between segmentation accuracy as measured by the Dice coefficient and percent feature error from ground truth for the vast majority of the features being examined. GLNDM-based texture parameters emerged as the top performing category of radiomcs features in terms of robustness against contouring variability for discretization schemes engaging number of gray levels of 32, 64, and 128 while GLCOM-based parameters stood out for discretization scheme engaging 256 gray levels. How and to what extent interrater reliability of radiomics features vary in response to the number of raters were largely feature-dependent. It was concluded that impact of contouring variability on PET-based radiomics features is present to varying degrees and could be experienced as a barrier to convey PET-based radiomics research to clinical relevance.
format Online
Article
Text
id pubmed-6962150
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-69621502020-01-23 Impact of contouring variability on oncological PET radiomics features in the lung Yang, F. Simpson, G. Young, L. Ford, J. Dogan, N. Wang, L. Sci Rep Article Radiomics features extracted from oncological PET images are currently under intense scrutiny within the context of risk stratification for a variety of cancers. However, the lack of robustness assessment poses problems for their application across institutions and for broader patient populations. The objective of the current study was to examine the extent to which radiomics parameters from oncological PET vary in response to manual contouring variability in lung cancer. Imaging data employed in the study consisted of 26 PET scans with lesions in the lung being created through the use of an anthropomorphic phantom in conjunction with Monte Carlo simulations. From each of the simulated lesions, 25 radiomics features related to the gray-level co-occurrence matrices (GLCOM), gray-level size zone matrices (GLSZM), and gray-level neighborhood difference matrices (GLNDM) were extracted from ground truth contour and from manual contours provided by 10 raters in regard to four intensity discretization schemes with number of gray levels of 32, 64, 128, and 256, respectively. The impact of interrater variability in tumor delineation upon the agreement between raters on radiomics features was examined via interclass correlation and leave-p-out assessment. Only weak and moderate correlations were found between segmentation accuracy as measured by the Dice coefficient and percent feature error from ground truth for the vast majority of the features being examined. GLNDM-based texture parameters emerged as the top performing category of radiomcs features in terms of robustness against contouring variability for discretization schemes engaging number of gray levels of 32, 64, and 128 while GLCOM-based parameters stood out for discretization scheme engaging 256 gray levels. How and to what extent interrater reliability of radiomics features vary in response to the number of raters were largely feature-dependent. It was concluded that impact of contouring variability on PET-based radiomics features is present to varying degrees and could be experienced as a barrier to convey PET-based radiomics research to clinical relevance. Nature Publishing Group UK 2020-01-15 /pmc/articles/PMC6962150/ /pubmed/31941949 http://dx.doi.org/10.1038/s41598-019-57171-7 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Yang, F.
Simpson, G.
Young, L.
Ford, J.
Dogan, N.
Wang, L.
Impact of contouring variability on oncological PET radiomics features in the lung
title Impact of contouring variability on oncological PET radiomics features in the lung
title_full Impact of contouring variability on oncological PET radiomics features in the lung
title_fullStr Impact of contouring variability on oncological PET radiomics features in the lung
title_full_unstemmed Impact of contouring variability on oncological PET radiomics features in the lung
title_short Impact of contouring variability on oncological PET radiomics features in the lung
title_sort impact of contouring variability on oncological pet radiomics features in the lung
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962150/
https://www.ncbi.nlm.nih.gov/pubmed/31941949
http://dx.doi.org/10.1038/s41598-019-57171-7
work_keys_str_mv AT yangf impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung
AT simpsong impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung
AT youngl impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung
AT fordj impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung
AT dogann impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung
AT wangl impactofcontouringvariabilityononcologicalpetradiomicsfeaturesinthelung