Cargando…
Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil
PURPOSE: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964328/ https://www.ncbi.nlm.nih.gov/pubmed/31969962 http://dx.doi.org/10.5114/pjr.2019.89906 |
_version_ | 1783488467005603840 |
---|---|
author | Akyel, Nazlı Gülsüm Akın, Kayıhan Kösehan, Dilek Köktener, Aslı |
author_facet | Akyel, Nazlı Gülsüm Akın, Kayıhan Kösehan, Dilek Köktener, Aslı |
author_sort | Akyel, Nazlı Gülsüm |
collection | PubMed |
description | PURPOSE: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. MATERIAL AND METHODS: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. RESULTS: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen’s κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen’s κ values signifyied good concordance between readers. CONCLUSIONS: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas. |
format | Online Article Text |
id | pubmed-6964328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-69643282020-01-22 Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil Akyel, Nazlı Gülsüm Akın, Kayıhan Kösehan, Dilek Köktener, Aslı Pol J Radiol Original Paper PURPOSE: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. MATERIAL AND METHODS: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. RESULTS: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen’s κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen’s κ values signifyied good concordance between readers. CONCLUSIONS: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas. Termedia Publishing House 2019-11-04 /pmc/articles/PMC6964328/ /pubmed/31969962 http://dx.doi.org/10.5114/pjr.2019.89906 Text en Copyright © Polish Medical Society of Radiology 2019 https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0). License allowing third parties to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. |
spellingShingle | Original Paper Akyel, Nazlı Gülsüm Akın, Kayıhan Kösehan, Dilek Köktener, Aslı Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title | Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title_full | Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title_fullStr | Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title_full_unstemmed | Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title_short | Perianal fistula imaging: a comparison between two-channel superficial Flex coil and eight-channel body coil |
title_sort | perianal fistula imaging: a comparison between two-channel superficial flex coil and eight-channel body coil |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964328/ https://www.ncbi.nlm.nih.gov/pubmed/31969962 http://dx.doi.org/10.5114/pjr.2019.89906 |
work_keys_str_mv | AT akyelnazlıgulsum perianalfistulaimagingacomparisonbetweentwochannelsuperficialflexcoilandeightchannelbodycoil AT akınkayıhan perianalfistulaimagingacomparisonbetweentwochannelsuperficialflexcoilandeightchannelbodycoil AT kosehandilek perianalfistulaimagingacomparisonbetweentwochannelsuperficialflexcoilandeightchannelbodycoil AT kokteneraslı perianalfistulaimagingacomparisonbetweentwochannelsuperficialflexcoilandeightchannelbodycoil |